Permit Number: T00CM05427
Parcel: 134244370

Address:
6305 E 22ND ST

Review Status: Completed

Review Details: SITE

Permit Number - T00CM05427
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/06/2000 PHIL SEADER HANDICAP-SITE REVIEW Denied
11/07/2000 JIM EGAN FIRE REVIEW Approved
11/19/2000 JOE LINVILLE LANDSCAPE REVIEW Denied 1. All revisions that affect site plan must also be made to the
landscape plan.

2. 50% of the landscape border must be covered with
shrubs or vegetative groundcover within two years. Tree
canopy does not count toward coverage requirements.
Vegetative screening may not be included in the groundcover
calculations. Please provide groundcover calculations for the
street landscape border.
3.7.2.4.A & Table 3.7.2-I / 2-06.3.4
3. All landscape and open areas, areas between the property
line and the sidewalk and areas between the sidewalk and
the street curb must receive dust control at a 2" depth. Identify
inorganic materials for the sidewalk area.
3.7.2.4.A.3
4. A 30" screen is required along 22nd Street. The screen must be located at the back (property side) of the landscape border. A vegetative screen or offset wall may encroach into the landscape border a maximum of 3'. A straight wall may encroach only for the width of the wall. Revise planting plan to show a continuous screen at the development side of the street border. Do not include the screen plantings in the calculations for 50% groundcover.
3.7.3 & Table 3.7.2-I /
2-06.3.7
5. The refuse storage areas must be screened with a 6' wall.
The area must be screened on all sides and may include solid gates for openings. Provide screening details for the refuse storage area on the landscape plan.
3.7.3 & Table 3.7.2-I /
2-06.3.7
6. Please place all screening requirements on the landscape plans.
/ 2-07.2.2
7. Please provide an irrigation plan. Locate and identify the source of water, controller and backflow preventer.
3.7.4, 3.7.4.5 / 2-06.5.0
8. All required landscaping, irrigation systems, walls, screening devices, curbing, and detention basin landscape improvements on the site or within the abutting right-of-way shall be maintained as shown on the approved plans. The property owner is responsible for proper maintenance to achieve permanent, safe, and successful landscaping as required by Article III, Division 7 of the City of Tucson's Land Use Code and Development Standard 2-06. Failure to maintain the improvements or landscaping pursuant to these code requirements constitutes a violation of the LUC. Please add notes to this affect to the landscape plans.
3.7.6 / 2-06.6.0
9. Up to 5' of the street landscape border may be located within the R.O.W. with the approval of the Engineering Department. On Major Streets and Routes, R.O.W. availability varies depending on future sidewalk locations.
3.7.2.9 / 2-06.2.2.M
10. All plants and other landscape materials must be located and
identified on the drawings. Identify vegetation in the right-of-way labeled as "M".
/ 2-07.2.2


RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Site Plan, Revised Landscape Plan.



If you have any questions about this transmittal, please call Joseph Linville at (520) 791-5550, Ext. 118.
11/19/2000 JOE LINVILLE NPPO REVIEW Approved Exc. previosly grade pad per C12-96-29 and aerial photo.
12/15/2000 DOUG WILLIAMS FLOODPLAIN REVIEW Approved
12/15/2000 DOUG WILLIAMS ENGINEERING REVIEW Denied
12/15/2000 DOUG WILLIAMS SANITATION REVIEW Denied
12/21/2000 DAN CASTRO ZONING REVIEW Denied

Final Status

Task End Date Reviewer's Name Type of Review Description
01/19/2001 DELMA ROBEY REJECT SHELF Completed
01/19/2001 DELMA ROBEY APPROVAL SHELF Completed
12/22/2000 DELMA ROBEY OUT TO CUSTOMER Completed