Review Date Reviewer's Name Type of Review Description Status Comments
10/26/2000 PATRICIA GEHLEN ZONING REVIEW Approved
10/26/2000 DOUG WILLIAMS FLOODPLAIN REVIEW Approved
10/26/2000 PGEHLEN NPPO REVIEW Passed
11/22/2000 TERRY STEVENS BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T00CM05279
11/27/00

PLEASE ADDRESS THE FOLLOWING COMMENTS. RESUBMIT TWO SETS OF CORRECTED PLANS. SUBMIT A COPY OF THIS LETTER , NOTING THE DETAIL AND OR SHEET WHERE THE CORRECTION MAY BE FOUND.

GENERAL REQUIREMENTS

1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.

FOUNDATION PLAN

1. SIZE OF FOOTINGS MISSING FOR MASONRY ARCHES AT FRONT PORCH.

FLOOR PLAN

1. SHOW COMPLIANCE WITH UBC SEC 1203.2 PROVIDING NATURAL LIGHT INTO ROOMS.
MISSING FOR BEDROOM ADJACENT TO NEW ADDITION AT FRONT

2. SHOW COMPLIANCE WITH UBC SEC 1203.3 PROVIDING NATURAL VENTILATION.
MISSING FOR BEDROOM ADJACENT TO NEW ADDITION AT FRONT

3. SHOW COMPLIANCE WITH UBC SEC 310.4 PROVIDING EGRESS FROM BEDROOMS OR BASEMENTS. SHOW MAXIMUM SILL HEIGHT OF 44".
MISSING FOR BEDROOM ADJACENT TO NEW ADDITION AT FRONT

NOTE: FOR NEW ADDITION TO BE CONSIDERED PART OF EXISTING BEDROOM THE ADJOINING WALL MUST BE 50% OR MORE OPEN.

4. INDICATE STEPS AND LANDINGS--------RISE AND RUN ETC.

STRUCTURAL

1. MIN. 18" CLEARANCE TO BOTTOM OF FLOOR JOISTS OR PROVIDE TREATED LUMBER

2. BOND BEAM MISSING AT TOP OF WALLS AT SECTION A-A AND AT ALL LEDGER CONNECTIONS

SECTIONS - DETAILS - MISCELLANEOUS NOTES

1. DETAIL AND NOTE ALL MASONRY WALL REINFORCEMENT. UBC CH.21

ELECTRICAL

1. DESIGNATE THE LOCATION OF ALL REQUIRED LIGHT FIXTURES, RECEPTACLE OUTLETS, POWER OUTLETS AND SWITCHES.
RECEPTACLES MISSING IN ADDITION AT FRONT
RECEPTACLES MISSING ALONG WALL BETWEEN EXISTING FAMILY ROOM AND NEW LIVING ROOM

MISCELLANEOUS

1. PROVIDE MODEL ENERGY CALCULATIONS. REQUIRED WHEN ADDITION IS GREATER THAN 20% OF EXISTING STRUCTURE. PERCENTAGE FORM IS ATTACHED

2. CALL OUT ON THE PLANS THE R-VALUES OF INSULATION, AS WELL AS THE U-VALUES OF THE WINDOWS IN CONFORMANCE WITH THE M.E.C. CALC'S PROVIDED.

IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
TERRY STEVENS: @ 791-5550 EXT. 112