Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T00CM05256
Parcel: 126210820

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING/FLOOD/WWM

Permit Number - T00CM05256
Review Name: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/11/2001 TERRY STEVENS BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T00CM05256
1/11/01
PLEASE ADDRESS THE FOLLOWING COMMENTS. RESUBMIT TWO SETS OF CORRECTED PLANS. SUBMIT A COPY OF THIS LETTER , NOTING THE DETAIL AND OR SHEET WHERE THE CORRECTION MAY BE FOUND.

GENERAL REQUIREMENTS

1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.

FOUNDATION PLAN

1. NOTE ON THE DRAWINGS THE ALLOWABLE SOIL BEARING PRESSURE USED IN THE DESIGN OF THE FOOTINGS, OR STATE THAT THE ASSUMED VALUE OF 1,000 PSF IS BEING USED.

2. A SOIL REPORT IS NOT REQUIRED. IT IS UP TO THE DESIGNER/HOMEBUILDER TO BE AWARE OF THE SOIL CONDITIONS OF THE SUBDIVISION. IF SOIL TESTING HAS BEEN DONE, A COPY OF THE SOILS REPORT SHALL BE SUBMITTED WITH THE CONSTRUCTION PLANS AND THE FOUNDATION DESIGN SHALL REFLECT SOIL REPORT RECOMMENDATIONS.

3. DIMENSION THE STEM WALL THICKNESS.

4. NOTE AND DETAIL MINIMUM REINFORCING:
WOOD FRAME -STEM WALL - TWO (2) #4 REBARS IN THE BOTTOM OF FOOTING
& ONE (1) #4 REBAR IN THE TOP OF STEM

5. DIMENSION INTERIOR FOOTINGS AND INDICATE MIN. DEPTH OF 12" BELOW NATURAL GRADE.

FLOOR PLAN

1. NOTE THAT SHOWER ENCLOSURES SHALL BE FINISHED WITH MOISTURE RESISTANT GYPSUM BOARD AND CERAMIC TILE OR EQUAL TO A HEIGHT OF 70" ABOVE THE DRAIN. UBC SEC 807.1.3.

STRUCTURAL

1. SPECIFY DESIGN CRITERIA: VALUES FOR FLOOR DEAD LOAD AND LIVE LOAD, ROOF DEAD LOAD AND LIVE LOAD.

2. GLULAM BEAM APPEARS TO BE OVERSPANNED------CHANGE OR SUBMIT CALCS. LOAD FROM EXISTING STRUCTURE NOT INDICATED PROPERLY. INDICATE CONNECTION DETAILS FOR 4X8 HIP BEAMS TO GLULAM [POINT LOAD ON GLULAM MUST BE CONSIDERED ALSO]

3. SPECIFY AND DETAIL ALL OVERFRAMING. IF SOLID SHEATHING IS USED ON THE LOWER TRUSSES, PROVIDE MINIMUM OPENINGS OF 22"X30" FOR ACCESS AND VENTILATION INTO OVER-FRAMED AREAS. IF SOLID SHEATHING IS NOT USED ON LOWER TRUSSES, PROVIDE DETAILS FOR BRACING OF TOP CHORD OF LOWER TRUSSES.

4. PLANS INDICATE ENGINEERING DETAIL SHEETS FOR TUBE STEEL AND CONNECTIONS----NONE PROVIDED

5. SPECIFY MAKE AND MODEL NUMBER OF ALL CONNECTORS AND HANGERS.

6. SPECIFY WEIGHT OF ROOF SYSTEM ITEMS...I.E. WEIGHT OF SELECTED TILE.
PROVIDE ICBO EVALUATION REPORT NUMBER AND MANUFACTURER OF ALL CONCRETE OR CLAY -TYPE TILE ROOFING.

ELEVATIONS

1. SHOW CALCULATION OF ATTIC VENTILATION AREA IN COMPLIANCE WITH UBC SEC 1505.3. NOTE LOCATION OF ALL VENTS NEEDED TO COMPLY.

2. FOR VENEER, NOTE AND SPECIFY TYPE OF VENEER. PROVIDE DETAIL AND SPECIFY ANCHORING METHOD, BACKING, VAPOR BARRIER, AND SUPPORT. UBC SEC 1403.
NOTE: MIN. AIRSPACE REQUIRED FOR VENEER IS 1" NOT ½"

SECTIONS - DETAILS - MISCELLANEOUS NOTES

1. SPECIFY FOUNDATION GRADE REDWOOD OR PRESSURE TREATED WOOD SILL PLATES. UBC SEC 2317.4.-DETAIL 2-D1

2. NOTE AND SPECIFY THE SIZE, SPACING AND LENGTH OF EMBEDMENT OF ANCHOR BOLTS FOR SILL PLATES.---DETAIL 2-D1

PLUMBING PLAN

1. GAS: PROVIDE THE LENGTH OF LINE TO EACH APPLIANCE, BTU DEMAND OF EACH APPLIANCE, SIZE OF EACH BRANCH, TOTAL DEMAND AND SIZE OF THE METER.

2. NOTE ON PLAN COMPLIANCE WITH WATER CONSERVATION; WATER CLOSETS 1.6 GALLONS PER FLUSH, SINKS AND SHOWERHEADS 3 GALLONS PER MINUTE. UPC CH.15 W/LOCAL MODIFICATIONS.

3. NOTE ON PLANS THAT SHOWER AND TUB / SHOWER COMBINATIONS THAT HAVE
INDIVIDUAL CONTROL VALVES SHALL BE OF THE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE. PER. U.P.C. 410.7

MECHANICAL

1. THE DWELLING MUST BE PROVIDED WITH HEATING CAPABLE OF MAINTAINING A ROOM TEMPERATURE OF 70 DEGREES AT A POINT THREE FEET ABOVE THE FLOOR. UBC SEC 310.11
NOTE:
1. PLANS INDICATE A HEAT PUMP---NOT INDICATED ON ELECTRICAL PLAN
2. MECH. SPECS. CALLOUT GAS FURNACE WITH CONDENSING UNIT
3. CONDENSING UNIT NOT LOCATED ON PLANS
4. ELEC. PANEL SCHEDULE DOES NOT SHOW ANY OF THE ABOVE
CLARIFY THE ABOVE AS TO WHAT IS BEING USED?

2. GAS APPLIANCES SHALL COMPLY WITH UMC CH.7 COMBUSTION AIR REQUIREMENTS. DETAIL HOW THIS IS ACHIEVED.

ELECTRICAL

1. NOTE THE LOCATION, TYPE AND AMPACITY OF THE PANEL, NOTE THE GROUNDING AND BONDING METHOD.

2. A RECEPTACLE OUTLET SHALL BE PROVIDED ADJACENT TO THE BASIN IN EACH BATHROOM. (N.E.C. ART.210-52). BATHROOM OUTLETS SHALL BE ON A SEPARATE 20 AMP CIRCUIT WITH NO OTHER OUTLETS (NEC ART. 210-52(d)). G.F.C.I. PROTECTION REQUIRED.

3. INDICATE THE LOCATION OF ALL AIR CONDITIONING AND HEATING UNITS, AIR HANDLERS, COMPRESSORS AND DISCONNECTS.

4. WHERE CEILING FANS ARE SHOWN ON THE PLANS, PROVIDE A NOTE INDICATING THAT ONLY APPROVED OUTLET BOXES SHALL BE USED. (N.E.C. ART 370-27(c).)

5. NOTE THAT LIGHT FIXTURES IN CLOTHES CLOSETS SHALL BE INSTALLED IN ACCORDANCE WITH (N.E.C. 410-8(d).)

6. NOTE THAT LIGHT FIXTURES IN TUB AND SHOWER AREAS SHALL BE INSTALLED IN ACCORDANCE WITH (N.E.C. 410-4(a)&(d).

IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
TERRY STEVENS: @ 791-5550 EXT. 112
01/11/2001 RAY MORGAN WWM REVIEW Approved
12/08/2000 PGEHLEN NPPO REVIEW Passed
12/08/2000 PATRICIA GEHLEN ZONING REVIEW Approved
12/11/2000 DOUG WILLIAMS FLOODPLAIN REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
01/23/2001 TAMI ACHONG OUT TO CUSTOMER Completed