Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Permit Number - T00CM05148
Review Name: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/18/2000 | PATRICIA GEHLEN | ZONING | REVIEW | Approved | |
| 10/18/2000 | PGEHLEN | NPPO | REVIEW | Passed | |
| 10/24/2000 | DOUG WILLIAMS | FLOODPLAIN | REVIEW | Approved | |
| 11/15/2000 | TERRY STEVENS | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T00CM05148 11/15/00 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESUBMIT TWO SETS OF CORRECTED PLANS. SUBMIT A COPY OF THIS LETTER , NOTING THE DETAIL AND OR SHEET WHERE THE CORRECTION MAY BE FOUND. GENERAL REQUIREMENTS 1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. SITE PLAN 1. PROVIDE LENGTH OF NEW 6' PATIO WALL 2. INDICATE THE LOCATION OF GAS LINES ON THE PROPERTY. FOUNDATION PLAN 1. NOTE AND DETAIL MINIMUM REINFORCING: MASONRY -STEM WALL -TWO (2) #4 IN THE BOTTOM OF FOOTING & ONE (1) #4 IN STEM WALL--HORIZONTAL & ONE (1) #4 VERTICAL BAR @ 48" OC FLOOR PLAN 1. PROVIDE THE LOCATIONS OF TEMPERED GLASS (UBC SEC 2406.4). REQUIRED WITH IN 24" OF A DOOR 2. APPLIANCES INSTALLED IN GARAGES SHALL BE MOUNTED ON PLATFORMS AT LEAST 18" ABOVE THE FLOOR. U.M.C. SEC. 308. 3. LANDING REQUIRED OUTSIDE DOOR TO BEDROOM 2------MAX. CHANGE IN ELEV. IS 8" STRUCTURAL 1. ROOF BEAM SIZE MISSING AT HALLWAY NEAR BEDROOM 3------DBL WHAT? 2. LINTEL SIZES MISSING FOR GARAGE DOOR OPENING AND OPENINGS FOR PATIO DOORS WITH SIDE LITES----12' AND 10' 3. SIZE OF ROOF FRAMING OVER BEDROOM 3 MISSING 4. TJI DOES NOT MFG. A 25 SERIES I-JOIST 5. COMPLETELY DETAIL ALL CONNECTIONS AND CROSS REFERENCE TO THE FOUNDATION AND FRAMING PLANS: - I-JOIST TO TOP PLATE - TOP PLATE TO MASONRY WALL - BEAM TO POST - POST TO SLAB 6. DETAIL 1-6.1 IS NOT REFLECTIVE OF AREA AT BEDROOM 3-------2X FRAMING NOT I-JOISTS DIFFERENT HANGERS ETC. 7. SPECIFY MAKE AND MODEL NUMBER OF ALL CONNECTORS AND HANGERS. PLUMBING PLAN 1. FUTURE SPA CANNOT BE PLUMBED INTO SEWER SYSTEM 2. PROVIDE PRESSURE AND TEMPERATURE RELIEF VALVE AT WATERHEATER (UPC SEC. 608.3) 3. NOTE ON PLANS THAT SHOWER AND TUB / SHOWER COMBINATIONS THAT HAVE INDIVIDUAL CONTROL VALVES SHALL BE OF THE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE. PER. U.P.C. 410.7 MECHANICAL 1. SHOW EXHAUST FAN LOCATIONS FOR BATHROOMS, WATER CLOSET COMPARTMENTS, AND LAUNDRY ROOMS IN LIEU OF OPERABLE WINDOWS. UBC SEC 1203 MISSING IN LAUNDRY AND MASTER BATHROOM 2. GAS APPLIANCES SHALL COMPLY WITH UMC CH.7 COMBUSTION AIR REQUIREMENTS. DETAIL HOW THIS IS ACHIEVED. 3. SHOW SIZES OF RETURN AIR AND SUPPLY AIR DUCTS. MIN. 2 SQ. IN. PER 1000 BTU--------SUPPLY DUCTS MISSING ELECTRICAL 1. SHOW LOCATION OF SMOKE DETECTORS PER U.B.C. 310.9. NOTE THAT ALL SMOKE DETECTORS MUST HAVE A POWER SOURCE FROM THE BUILDING WIRING AND SHALL BE EQUIPPED WITH A BATTERY BACKUP. MISSING AT ACCESS TO BEDROOMS MISCELLANEOUS 1. CALL OUT ON THE PLANS THE R-VALUES OF INSULATION, AS WELL AS THE U-VALUES OF THE WINDOWS IN CONFORMANCE WITH THE M.E.C. CALC'S PROVIDED. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: TERRY STEVENS: @ 791-5550 EXT. 112 |
| 11/15/2000 | RAY MORGAN | WWM | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/27/2000 | CLAUDIA BUFORD | APPROVAL SHELF | Passed |
| 11/27/2000 | CLAUDIA BUFORD | OUT TO CUSTOMER | Passed |
| 11/20/2000 | CLAUDIA BUFORD | REJECT SHELF | Passed |