Permit Number: T00CM05070
Parcel: 11612303A

Review Status: Completed

Review Details: COMMERCIAL TI

Permit Number - T00CM05070
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/12/2000 PETER MCLAUGHLIN ZONING REVIEW Approved
10/12/2000 PMCLAUGH NPPO REVIEW Passed
10/13/2000 JIM SINGLETON MECHANICAL-COMMERCIAL REVIEW Approved
10/13/2000 DOUG LAAKSO BUILDING-COMMERCIAL REVIEW Denied S1) CLARIFY ,ON DRAWINGS, 'S' OCCUPANCY,ie: WHAT IS BEING STORED. S2) SHOW HOW CENTER PORTION OF BUILDING IS BEING USED, DWG A1.1. S3) SHOW CONNECTIONS OF NEW PARTITIONS AND BRACING TO STRUCTURE ABOVE AND BELOW, INCLUDING FASTENER (TYPE ,SIZE, SPACING/NUMBER. S4) PROVIDE CROSS-SECTIONS SHOWING : MATERIALS OF CONSTRUCTION, CODE COMPLIANCE,CONNECTIONS TO STRUCTURE ABOVE, BELOW,AND ADJACENT , INCLUDING FASTENER (TYPE, SIZE SPACING/NUMBER), AT BLOCK INFILL AND FRAME INFILL. S5) CLARIFY WINDOW LOCATIONS re: SAFETY GLAZING REQ'M'TS OF UBC. S6) CLARIFY ACCESSIBILITY : WHERE IS 20% OF ATERATION COST SPENT ON ACCESSIBILITY PER 1994 UBC , CHAPTER 11, AS AMENDED(BY ESTIMATE ON DRAWINGS) INCLUDING SITE PLAN. S7) CORNER TOILET, SWING DOOR OUT,AS DOOR IS NOT ALLOWED TO SWING INTO WHEELCHAIR TURNAROUND AREA. S8) IF THIS IS A CHANGE OF OCCUPANCY, ENTIRE PROJECT SHALL BE BROUGHT INTO COMPLIANCE WITH CURRENT CODE. EXPLAIN. S9 SHOW STRUCTURAL REQUIRED FOR NEW UNITS ON ROOF :PROVIDE DETAILS ,FRAMING AND SEALED DRAWINGS BY STRUCTURAL ENGINEER.
10/13/2000 JIM EGAN FIRE REVIEW Approved
10/13/2000 JIM SINGLETON PLUMBING-COMMERCIAL REVIEW Approved
10/13/2000 RANDY SCHULER ELECTRICAL-COMMERCIAL REVIEW Approved
10/23/2000 RAY MORGAN WWM REVIEW Passed

Final Status

Task End Date Reviewer's Name Type of Review Description
10/23/2000 TAMI ACHONG APPROVAL SHELF Completed
10/23/2000 TAMI ACHONG OUT TO CUSTOMER Completed
10/23/2000 TAMI ACHONG REJECT SHELF Completed