Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Permit Number - T00CM04703
Review Name: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/21/2000 | PETER MCLAUGHLIN | ZONING | REVIEW | Approved | |
| 09/21/2000 | DOUG WILLIAMS | FLOODPLAIN | REVIEW | Approved | |
| 09/26/2000 | JOE LINVILLE | NPPO | REVIEW | Denied | See attached comments. |
| 10/16/2000 | TERRY STEVENS | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T00CM004703 10/17/00 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESUBMIT TWO SETS OF CORRECTED PLANS. SUBMIT A COPY OF THIS LETTER , NOTING THE DETAIL AND OR SHEET WHERE THE CORRECTION MAY BE FOUND. GENERAL REQUIREMENTS 1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. FOUNDATION PLAN 1. ALL FOUNDATION HOLDDOWNS AND ANCHOR BOLT SPACING FOR SHEAR WALLS SHALL BE SPECIFIED, LOCATED AND DETAILED. FLOOR PLAN 1. FIREPLACES: -INDICATE FIREPLACE LOCATION, HEARTH SIZE AND MATERIALS 2. IDENTIFY CEILING HEIGHTS IN ALL AREAS ON FLOOR PLAN. IF SLOPED CEILING NOTE AVERAGE HEIGHT.-------NOTE: CHANGE IN ELEVATIONS REGARDING WALL HEIGHT WILL AFFECT CEILING HEIGHT AND/OR ROOF FRAMING--------CLARIFY STRUCTURAL 1. BLOCKING REQUIRED UNDER BEARING WALL AT DETAIL 4-6 2. PROVIDE DETAILS FOR FRONT PORCH CONNECTIONS OF RIDGE TO JOISTS, JOISTS TO BEAM ,ETC. 3. SPECIFY MAKE AND MODEL NUMBER OF ALL CONNECTORS AND HANGERS. SECTIONS - DETAILS - MISCELLANEOUS NOTES 1. PROVIDE A BUILDING CROSS SECTION. MORE THAN ONE MAY BE REQUIRED TO CLEARLY ILLUSTRATE HOW THE STRUCTURE IS BUILT.-----------PROVIDE FOR FRONT PORCH PLUMBING PLAN 1. ISOMETRIC DRAWING OF WASTE LINES PROVIDED DOES NOT MATCH PLAN VIEW. LAV. MISSING, ROUTING AT LAVS. DIFFERENT,-------PLAN VIEW SHOWS TWO TRAPS ON ONE DIRTY ARM AT LAVS., NOT TO CODE 2. NOTE ON PLAN COMPLIANCE WITH WATER CONSERVATION; WATER CLOSETS 1.6 GALLONS PER FLUSH, SINKS AND SHOWERHEADS 3 GALLONS PER MINUTE. UPC CH.15 W/LOCAL MODIFICATIONS. 3. PROVIDE PRESSURE AND TEMPERATURE RELIEF VALVE AT WATERHEATER (UPC SEC. 608.3)------MUST EXTEND TO OUTSIDE SOURCE NOT INTO WASTE LINES 4. NOTE ON PLANS THAT SHOWER AND TUB / SHOWER COMBINATIONS THAT HAVE INDIVIDUAL CONTROL VALVES SHALL BE OF THE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE. PER. U.P.C. 410.7 MECHANICAL 1. GAS APPLIANCES SHALL COMPLY WITH UMC CH.7 COMBUSTION AIR REQUIREMENTS. DETAIL HOW THIS IS ACHIEVED.---------VENTS IN DOOR INTO HALL NOT ALLOWED FOR WATER HEATER AREA------EXTEND TO OUTSIDE, THE ATTIC, OR REMOVE DOOR 2. SHOW SIZES OF RETURN AIR DUCTS. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: TERRY STEVENS: @ 791-5550 EXT. 112 |
| 10/19/2000 | CBUFORD | WWM | REVIEW | Denied |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/16/2000 | TAMI ACHONG | APPROVAL SHELF | Completed |
| 11/16/2000 | TAMI ACHONG | REJECT SHELF | Completed |
| 10/27/2000 | TAMI ACHONG | OUT TO CUSTOMER | Completed |