Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T00CM04675
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/17/2000 | JIM EGAN | FIRE | REVIEW | Approved | |
| 10/27/2000 | PATRICIA GEHLEN | ZONING | REVIEW | Denied | |
| 11/19/2000 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1. Revisions made to the site plan must also be shown on the landscape plan 2-07.0 2. One 15 gal. tree per 33 L.F. of property frontage minus entry/exit widths is required within the Presidio Street landscape border. The border area is measured from the proposed screen. Trees for the border must be located in front of the required screens. a. 50% of the landscape border must be covered with shrubs or vegetative groundcover within two years. Tree canopy does not count toward coverage requirements. b. All plant materials, including seed mixes, must be from the approved plant list found in the Development Standards (DS 9-06) and identified on the plans. All plants must be identified as to their genus, species and quantity. c. Provide calculations for oasis areas. 3.7.2.4.A & Table 3.7.2-I / 2-06.3.4 3. A 10' wide interior landscape border is required on the west side(s) of the property. The interior landscape border must contain the following: a. One 15 gal. tree must be provided within the border for every 33' of property line. b. Dust control at a 2" depth. The 10' width may be altered if a PAAL or parking area conflicts with the border, provided the required number of trees are distributed evenly between the principal use and the property line. A min. area of 34 S.F. with a minimum width of 4' is provided for each tree. The tree requirement must be satisfied in addition to trees required for vehicle use areas and street borders. Please provide calculations for required trees. 3.7.2.4.B & Table 3.7.2-I / 2-06.3.4 4. Within a vehicular use area, one canopy tree is required for every 15 parking spaces provided or fraction thereof. A minimum of 50% of the required trees must be located within the vehicular use area. Please provide calculations for vehicular use area trees. 3.7.2.3 / 2-06.3.3 5. A 5' screen is required along Presidio Street only for the parking area. The screen must be located at the back (property side) of the landscape border. A vegetative screen or offset wall may encroach into the landscape border a maximum of 3'. A straight wall may encroach only for the width of the wall. 3.7.3 & Table 3.7.2-I / 2-06.3.7 6. A masonry wall is required along the property lines where the vehicle use area is not screened by the proposed buildings. Locate and identify the required walls on the landscape plan. All landscape areas adjacent to vehicle use areas must be protected from damage. Show curbing and/ or other suitable barriers on the landscape and site plans. 3.7.3 & Table 3.7.2-I / 2-06.3.7 7. The refuse storage areas must be screened with a 6' wall. 3.7.3 & Table 3.7.2-I / 2-06.3.7 8. Please place all screening requirements on the landscape plan. / 2-07.2.2 9. Please provide an irrigation plan. Locate and identify the source of water, controller and backflow preventer. 3.7.4, 3.7.4.5 / 2-06.5.0 10. All plants and other landscape materials must be located and identified on the drawings. / 2-07.2.2 NATIVE PLANT PRESERVATION (NPPO) COMMENTS CODE SECTION/ DEVELOPMENT STD. 1. If protected native plants do not exist on the site or will not be substantially impacted by development, please submit an application for an exception to the Native Plant Preservation requirements. a. If protected native plants exist on site but will not be impacted by development, please locate and identify the protected plants on the site, landscape and grading plans. Plants should be identified as to their genus, species and size and notes must be added stating that these plants will be preserved in place and fenced for protection prior to any land disturbance activity. 3.8.3.4.D, 3.8.3.4.E & 3.8.5/2-15.2.0 2. If protected native plants do exist on the site, please have a plant professional provide all data required for the NPPO. These requirements shall be submitted by one of the following methods. a. Plant Inventory Methodology - Submit all requirements for this method, including but not limited to: a Native Plant Inventory per DS Sec. 2-15.3.1, an Analysis and Objectives Statement per DS Sec. 2-15.3.3 and a Plant Preservation and Salvage Plan per DS 2-15.3.4. b. Plant Appraisal Methodology - Submit all requirements for this method including but not limited to, a Plant Appraisal per LUC Sec. 3.8.6.3 based on a Native Plant Inventory for each plant to be removed from the site per DS 2-15.3.1. c. Set Aside Methodology - Submit all requirements for this method including but not limited to, an Environmental Resource Report per LUC Sec. 3.8.6.4 and DS 1-07. d. Combined Methodologies - Submit all requirements for this method as stated in the LUC Sec 3.8.6.5 and the related DS Sections. 3.8.0 / 2-15.0 3.8.6.2 / 2-15 3.8.6.3 / 2-15 3.8.6.4 / 2-15 3.8.6.5 / 2-15 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Site Plan, Revised Landscape Plan, NPPO Plan or application for exception. If you have any questions about this transmittal, please call Joseph Linville at (520) 791-5550, Ext. 118. |
| 11/24/2000 | DOUG WILLIAMS | FLOODPLAIN | REVIEW | Denied | |
| 11/24/2000 | DOUG WILLIAMS | ENGINEERING | REVIEW | Denied | |
| 11/24/2000 | PHIL SEADER | HANDICAP-SITE | REVIEW | Approved | |
| 11/24/2000 | DOUG WILLIAMS | SANITATION | REVIEW | Denied |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/29/2000 | TAMI ACHONG | OUT TO CUSTOMER | Completed |