Permit Number: T00CM04640
Parcel: 13303304B

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T00CM04640
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/27/2000 TERRY STEVENS BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T00CM04640
10/9/00 2nd REVIEW 10/27/00

PLEASE ADDRESS THE FOLLOWING COMMENTS. RESUBMIT TWO SETS OF CORRECTED PLANS. SUBMIT A COPY OF THIS LETTER , NOTING THE DETAIL AND OR SHEET WHERE THE CORRECTION MAY BE FOUND.

GENERAL REQUIREMENTS

1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.

STRUCTURAL

1. PROVIDE COMPLETE ROOF AND FLOOR FRAMING PLANS. SHOW SIZE, SPACING AND SPAN OF ALL FRAMING MEMBERS, TRUSSES, JOISTS, RAFTERS, BEAMS, GLU-LAMS, LINTELS HEADERS, LEDGERS AND BLOCKING.
NOTE:
1. ALL FLOOR JOISTS SPANNING 14'-6" AND OVER APPEAR TO BE INADEQUATE-----CHANGE OR SUBMIT CALCS.----CALCS. SUBMITTED SHOW JOISTS OVERSPANNED
2. ALL LINTELS OVER 4' APPEAR TO BE INADEQUATE INCLUDING GARAGE-----CHANGE OR SUBMIT CALCS.-SEE ATTACHED LINTEL SCHEDULE

SECTIONS - DETAILS - MISCELLANEOUS NOTES

1. MASONRY WALLS SHALL BE ANCHORED TO FLOORS AND ROOFS WHICH PROVIDE LATERAL SUPPORT FOR THE WALL. DETAIL A POSITIVE DIRECT CONNECTION CAPABLE OF RESISTING THE HORIZONTAL FORCES. SEE UBC SEC 2109.
DETAIL PAT STRAPS AT JOISTS PARALLEL TO MASONRY WALLS WITH BLOCKING OF 3 BAYS ---------FLOOR JOISTS ARE LEDGERED TO WALL NOT TOP LOADING

IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
TERRY STEVENS: @ 791-5550 EXT. 112
10/31/2000 RAY MORGAN WWM REVIEW Denied
11/15/2000 JOE LINVILLE NPPO REVIEW Denied

Final Status

Task End Date Reviewer's Name Type of Review Description
01/30/2001 DELMA ROBEY OUT TO CUSTOMER Completed
01/30/2001 DELMA ROBEY REJECT SHELF Completed
11/16/2000 DELMA ROBEY APPROVAL SHELF Completed