Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T00CM04270
Parcel: 117180830

Address:
414 W ROSALES ST

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING/FLOOD/WWM

Permit Number - T00CM04270
Review Name: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/28/2000 DAVID RIVERA ZONING REVIEW Approved
08/28/2000 DOUG WILLIAMS FLOODPLAIN REVIEW Approved
09/12/2000 TERRY STEVENS BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T00CM04270
9/12/00

PLEASE ADDRESS THE FOLLOWING COMMENTS. RESUBMIT TWO SETS OF CORRECTED PLANS. SUBMIT A COPY OF THIS LETTER , NOTING THE DETAIL AND OR SHEET WHERE THE CORRECTION MAY BE FOUND.

GENERAL REQUIREMENTS

1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.

FOUNDATION PLAN

1. NOTE AND DETAIL MINIMUM REINFORCING:

MASONRY -STEM WALL -TWO (2) #4 IN THE BOTTOM OF FOOTING
& ONE (1) #4 IN STEM WALL
& ONE (1) #4 VERTICAL BAR @ 48" OC

2. LOCATE AND DETAIL ALL FOOTINGS FOR THE FOLLOWING:
FIREPLACE

3. LOCATE AND SPECIFY ALL ANCHOR BOLT SPACING AND POST ANCHORS ON THE FOUNDATION PLAN.---------- AB TYPE POST ANCHORS DO NOT HAVE ANY UPLIFT VALUES USE THE ABA , ABU, ABE OR OTHER APPROVED TYPE POST CONNECTOR

FLOOR PLAN

1. PROVIDE ALL WINDOW SIZES AND TYPES, AND DESIGNATE THE OPERABLE PORTION OF WINDOWS AS WELL AS THE LOCATIONS OF TEMPERED GLASS (UBC SEC 2406.4).
NOTE: WINDOWS WITHIN 24" OF A DOOR REQUIRE TEMPERED GLAZING

2. SHOW COMPLIANCE WITH UBC SEC 1203.2 PROVIDING NATURAL LIGHT INTO ROOMS.

3. SHOW COMPLIANCE WITH UBC SEC 1203.3 PROVIDING NATURAL VENTILATION.

4. SHOW COMPLIANCE WITH UBC SEC 310.4 PROVIDING EGRESS FROM BEDROOMS OR BASEMENTS. SHOW MAXIMUM SILL HEIGHT OF 44".

5. COMPLY WITH SEC 302.4 EXCEPTION 3. PROVIDE 5/8" TYPE X GYPSUM BOARD ON ALL WALLS COMMON TO THE GARAGE AND HOUSE, AND ON ALL GARAGE BEARING WALLS AND 2 LAYERS ½" TYPE X GWB ON CEILINGS.--------IN ORDER TO BE CONSIDERED A CARPORT TWO SIDES MUST BE 50% OR MORE OPEN OTHERWISE IT IS A GARAGE

6. NOTE THAT SHOWER ENCLOSURES SHALL BE FINISHED WITH MOISTURE RESISTANT GYPSUM BOARD AND CERAMIC TILE OR EQUAL TO A HEIGHT OF 70" ABOVE THE DRAIN. UBC SEC 807.1.3.

7. FIREPLACES:
-INDICATE FIREPLACE LOCATION, HEARTH SIZE AND MATERIALS
-FOR FACTORY BUILT OR ZERO CLEARANCE FIREPLACES - PROVIDE CUT SHEET, MAKE, MODEL NUMBER AND THE APPROVAL NUMBER OF THE TESTING AGENCY (I.E. ICBO #).
- FOR MASONRY FIREPLACES - SHOW CROSS SECTION

STRUCTURAL

1. ½" T1-11 NOT RATED FOR ROOF SHEATHING

2. NOTE AND DETAIL JOIST HANGERS BY TYPE, SIZE AND REQUIRED ATTACHMENT TO FRAMING MEMBERS.-----DETAIL 3-A4

ELEVATIONS

1. SHOW CALCULATION OF ATTIC VENTILATION AREA IN COMPLIANCE WITH UBC SEC 1505.3. NOTE LOCATION OF ALL VENTS NEEDED TO COMPLY.

2. NOTE AND DIMENSION THAT THE FIREPLACE CHIMNEY MUST TERMINATE A MINIMUM OF TWO FEET ABOVE ANY POINT OF A ROOF WITHIN TEN FEET MEASURED HORIZONTALLY. UBC TABLE 31 B.

SECTIONS - DETAILS - MISCELLANEOUS NOTES

1. DETAIL MASONRY FIREPLACES: PROVIDE DIMENSIONED AND NOTED SECTIONS AND FIRE-BOX PLAN. STATE FLUE SIZE, DIMENSION HEARTH WIDTH, AND REINFORCING. NOTE AND DETAIL ANCHORAGE TIE STRAPS FASTENED TO A MINIMUM OF FOUR JOISTS WITH 2-1/2" BOLTS EMBEDDED INTO MASONRY AND ENGAGING THE OUTER REINFORCING BARS WITH A SIX INCH HOOKED EXTENSION.

ELECTRICAL

1. DESIGNATE THE LOCATION OF ALL REQUIRED LIGHT FIXTURES, RECEPTACLE OUTLETS, POWER OUTLETS AND SWITCHES.-------ALSO CROSS REFERENCE ALL TO PANEL SCHEDULE

2. A RECEPTACLE OUTLET SHALL BE PROVIDED ADJACENT TO THE BASIN IN EACH BATHROOM. (N.E.C. ART.210-52). BATHROOM OUTLETS SHALL BE ON A SEPARATE 20 AMP CIRCUIT WITH NO OTHER OUTLETS (NEC ART. 210-52(d)). G.F.C.I. PROTECTION REQUIRED.

3. NOTE THAT TWO OR MORE 20 AMP SHALL APPLIANCE CIRCUITS SHALL BE PROVIDED TO SERVE THE KITCHEN, BREAKFAST ROOM AND DINING ROOM. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. (N.E.C. ART.210-52.)

4. NOTE THAT AT LEAST ONE 20 AMP BRANCH CIRCUIT SHALL BE INSTALLED TO SERVE THE LAUNDRY ROOM AND THIS CIRCUIT SHALL HAVE NO OTHER OUTLETS. LIGHTING ON THIS CIRCUIT NOT ALLOWED.( N.E.C. 210-52(f) AND 220-4(c).)

MISCELLANEOUS

1. PROVIDE TOW COPIES OF MODEL ENERGY CALCULATIONS.

2. CALL OUT ON THE PLANS THE R-VALUES OF INSULATION, AS WELL AS THE U-VALUES OF THE WINDOWS IN CONFORMANCE WITH THE M.E.C. CALC'S PROVIDED.

IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
TERRY STEVENS: @ 791-5550 EXT. 112
09/13/2000 RAY MORGAN WWM REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
09/20/2000 DELMA ROBEY APPROVAL SHELF Completed
09/20/2000 DELMA ROBEY OUT TO CUSTOMER Completed
09/20/2000 DELMA ROBEY REJECT SHELF Completed