Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T00CM04141
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/30/2000 | TERRY STEVENS | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T00CM04141 10/30/00 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESUBMIT TWO SETS OF CORRECTED PLANS. SUBMIT A COPY OF THIS LETTER , NOTING THE DETAIL AND OR SHEET WHERE THE CORRECTION MAY BE FOUND. GENERAL REQUIREMENTS 1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. SITE PLAN 1. INDICATE THE LOCATION OF GAS AND WATER LINES ON THE PROPERTY AND WHERE THEY ENTER THE BUILDING. FOUNDATION PLAN 1. DIMENSION THE STEM WALL THICKNESS, FOOTING WIDTH THICKNESS AND DEPTH INTO UNDISTURBED SOIL FOR EACH FOOTING TYPE AND CONDITION. 2. PROVIDE FOUNDATION DETAILS ON THE FOUNDATION PLAN SHEET OR ON A SEPARATE DETAIL SHEET. DETAILS SHALL BE CROSS-REFERENCED TO THE FOUNDATION PLANS. 3. LOCATE AND DETAIL ALL FOOTINGS FOR THE FOLLOWING: MISSING FOR NEW CARPORT POST FOOTINGS-----MISSING AT ENDS OF BEAMS IN DEN FLOOR PLAN 1. SHOW COMPLIANCE WITH UBC SEC 1203.2 PROVIDING NATURAL LIGHT INTO ROOMS. INDICATE FOR EXISTING LIVING ROOM AND DEN 2. SHOW COMPLIANCE WITH UBC SEC 1203.3 PROVIDING NATURAL VENTILATION. INDICATE FOR EXISTING LIVING ROOM AND DEN 3. SHOW THAT EACH WATER CLOSET IS LOCATED IN A CLEAR SPACE NOT LESS THAN 30" WIDE AND HAS A CLEAR SPACE IN FRONT OF NOT LESS THAN 24" PER UBC SEC 2904. STRUCTURAL 1. PROVIDE COMPLETE ROOF AND FLOOR FRAMING PLANS. SHOW SIZE, SPACING AND SPAN OF ALL FRAMING MEMBERS, TRUSSES, JOISTS, RAFTERS, BEAMS, GLU-LAMS, LINTELS HEADERS, LEDGERS AND BLOCKING. ROOF FRAMING PLAN MISSING FOR NEW CARPORT AND ADJACENT CARPORT HEADER SIZES MISSING FOR ADDITION AS WELL AS NEW ENTRY FROM LIVING ROOM 2. PROVIDE A HEADER SCHEDULE OR NOTE HEADER SIZES AT ALL BEARING OPENINGS ON FRAMING OR FLOOR PLANS. 3. 4X6 BEAMS OVER DEN AREA ARE INADEQUATE FOR SPAN INDICATED 4. COMPLETELY DETAIL ALL CONNECTIONS AND CROSS REFERENCE TO THE FOUNDATION AND FRAMING PLANS: - BEAM TO POST - POST TO SLAB - SILL TO SLAB, ANCHOR BOLT SIZES AND SPACING, POST TO SILL PLATE 5. SHOW DETAILS FOR ALL BEARING AND CRITICAL NON-BEARING CONDITIONS. ELEVATIONS 1. PROVIDE COMPLETE DRAWINGS OF ALL ELEVATIONS. INCLUDE PATIO COVERS, DECKS, FIREPLACES AND BAY WINDOWS. SHOW BUILDING HEIGHTS. 2. NOTE AND SPECIFY ALL ROOF SLOPES. MINIMUM ROOF SLOPE 3/8" PER FOOT. UBC SEC 1506.1 AND LOCAL AMENDMENT. SECTIONS - DETAILS - MISCELLANEOUS NOTES 1. PROVIDE A BUILDING CROSS SECTION. MORE THAN ONE MAY BE REQUIRED TO CLEARLY ILLUSTRATE HOW THE STRUCTURE IS BUILT. 2. CROSS - SECTIONS SHALL BE CROSS REFERENCED TO THE FLOOR PLAN AND FRAMING PLANS. PLUMBING PLAN 1. NOTE AND SPECIFY ALL PIPING MATERIALS. 2. NOTE ON PLANS THAT SHOWER AND TUB / SHOWER COMBINATIONS THAT HAVE INDIVIDUAL CONTROL VALVES SHALL BE OF THE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE. PER. U.P.C. 410.7 MECHANICAL 1. SHOW EXHAUST FAN LOCATIONS FOR BATHROOMS, WATER CLOSET COMPARTMENTS, AND LAUNDRY ROOMS IN LIEU OF OPERABLE WINDOWS. UBC SEC 1203 2. SHOW SIZES AND LOCATION OF RETURN AIR DUCTS. ELECTRICAL 1. DESIGNATE THE LOCATION OF ALL REQUIRED LIGHT FIXTURES, RECEPTACLE OUTLETS, POWER OUTLETS AND SWITCHES. REQUIRED WITHIN 6' OF A DOOR AND NO FURTHER THAN 12' APART MEASURED ALONG THE WALL------MISSING IN DEN AND BEDROOMS 2. WHERE CEILING FANS ARE SHOWN ON THE PLANS, PROVIDE A NOTE INDICATING THAT ONLY APPROVED OUTLET BOXES SHALL BE USED. (N.E.C. ART 370-27(c).) 3. SHOW LOCATION OF SMOKE DETECTORS PER U.B.C. 310.9. MISCELLANEOUS 1. PROVIDE MODEL ENERGY CALCULATIONS. 2. CALL OUT ON THE PLANS THE R-VALUES OF INSULATION, AS WELL AS THE U-VALUES OF THE WINDOWS IN CONFORMANCE WITH THE M.E.C. CALC'S PROVIDED. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: TERRY STEVENS: @ 791-5550 EXT. 112 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/14/2000 | TAMI ACHONG | APPROVAL SHELF | Completed |
| 11/14/2000 | TAMI ACHONG | OUT TO CUSTOMER | Completed |
| 11/14/2000 | TAMI ACHONG | REJECT SHELF | Completed |