Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T00CM02777
Parcel: 113110080

Address:
1802 E GRANT RD

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T00CM02777
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/15/2001 DOUG LAAKSO BUILDING-COMMERCIAL REVIEW Denied 1. SEE PRIOR COMMENT #1. 2. SEE PRIOR COMMENT #2. FIRE DOORS REQUIRE CLOSERS PER UBC, SEC, #1005.8.1. CLARIFY USE AND FUNCTION OF DOOR HARDWARE ie: LEVER HANDLE HARDWARE , OPENABLE FROM INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EQUIPMENT. 3. SEE PRIOR COMMENT #3. 1. SPECIFY FULLY HANDRAILS ie: STRUCTURAL DESIGN REQUIREMENTS, PER 1994 UBC,FOOTNOTE #11, TABLE 16-B, SPECIAL LOADS CATEGORY #11, HANDRAILS "THE MOUNTING OF HANDRAILS SHALL BE SUCH THAT THE COMPLETED HANDRAIL AND SUPPORTING STRUCTURE ARE CAPABLE OF WITHSTANDING A LOAD OF AT LEAST 200 POUNDS (890 kN) APPLIED IN ANY DIRECTION AT ANY POINT ON THE RAIL. THESE LOADS SHALL NOT BE ASSUMED TO ACT CUMULATIVELY WITH ITEM 9." 2. SEE PRIOR COMMENT #3.3. EXTENSIONS 12" BEYOND TOP RISER AND AT LEAST 12" PLUS THE WIDTH OF ONE TREAD BEYOND THE BOTTOM RISER. AT THE TOP , THE EXTENSION SHALL BE PARALLEL TO THE FLOOR OR GROUND SURFACE. AT THE BOTTOM , THE HANDRAIL SHALL CONTINUE TO SLOPE FOR A DISTANCE OF THE WIDTH OF ONE TREAD FROM THE BOTTOM RISER; THE REMAINDER OF THE EXTENSION SHALL BE HORIZONTAL. 4.SEE PRIOR COMMENT #4. 1. 60" x 60" LANDING REQUIRED AT TOP OF RAMP FOR TURN THROUGH DOOR #2. 2. REVISE VESTIBULE TO ACCOMMODATE RAMPS, LANDINGS, STAIRS AND HANDRAILS. 3. SEE PRIOR COMMENT #4.4-SEE ITEM #3.1 ABOVE 4. SEE PRIOR COMMENT #4.5. CLARIFY 12" EXTENSIONS AT RAMP AT ENTRY COURT WEST HANDRAIL AT TOP, SIMILAR AT VESTIBULE AT DOOR #2 LANDING. 5. SEE PRIOR COMMENT #5.2.1. DIMENSION CLEARANCES UNDER LAVATORY TO SHOW CONFORMANCE TO UBC, SEC. #1106.11.7. SEE PRIOR COMMENTS DATED (2/2/01) AND (7/17/00) ATTACHED
02/23/2001 HOLLY PEARCE PLUMBING-COMMERCIAL REVIEW Approved
02/23/2001 HOLLY PEARCE MECHANICAL-COMMERCIAL REVIEW Approved
02/26/2001 RANDY SCHULER ELECTRICAL-COMMERCIAL REVIEW Approved
02/26/2001 PHIL SEADER HANDICAP-SITE REVIEW Approved
03/01/2001 GERRY KOZIOL WWM REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
03/08/2001 MVALDEZ OUT TO CUSTOMER Completed
03/01/2001 DELMA ROBEY REJECT SHELF Completed