Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T00CM00338
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/11/2000 | TERRY STEVENS | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T00CM00338 10/11/00 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESUBMIT TWO SETS OF CORRECTED PLANS. SUBMIT A COPY OF THIS LETTER , NOTING THE DETAIL AND OR SHEET WHERE THE CORRECTION MAY BE FOUND. GENERAL REQUIREMENTS 1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. FLOOR PLAN 1. PROVIDE ACCESS TO EACH SEPARATE ATTIC AND CRAWL SPACE. DESIGNATE LOCATIONS ON THE DRAWINGS. OPENINGS SHALL NOT BE LESS THAN 22"X30" THE LOCATION OF THE ATTIC ACCESS SHALL PROVIDE A MINIMUM OF 30" OF HEADROOM. UBC SEC 1505.1 2. SHOW THAT EACH WATER CLOSET IS LOCATED IN A CLEAR SPACE NOT LESS THAN 30" WIDE AND HAS A CLEAR SPACE IN FRONT OF NOT LESS THAN 24" PER UBC SEC 2904. 3. IDENTIFY CEILING HEIGHTS IN ALL AREAS ON FLOOR PLAN. IF SLOPED CEILING NOTE AVERAGE HEIGHT. STRUCTURAL 1. PROVIDE COMPLETE ROOF FRAMING PLANS. SHOW SIZE, SPACING AND SPAN OF ALL FRAMING MEMBERS AND HEADER. MISSING FOR WATER HEATER ROOM ELEVATIONS 1. LOCATE EXTERIOR WALL BRACING, IF USED. UBC SEC 2326.11.3 2. SHOW CALCULATION OF ATTIC VENTILATION AREA IN COMPLIANCE WITH UBC SEC 1505.3. NOTE LOCATION OF ALL VENTS NEEDED TO COMPLY. SECTIONS - DETAILS - MISCELLANEOUS NOTES 1. PROVIDE A BUILDING CROSS SECTION. MORE THAN ONE MAY BE REQUIRED TO CLEARLY ILLUSTRATE HOW THE STRUCTURE IS BUILT. 2. CROSS - SECTIONS SHALL BE CROSS-REFERENCED TO THE FLOOR PLAN AND FRAMING PLANS. PLUMBING PLAN 1. NOTE ON PLAN COMPLIANCE WITH WATER CONSERVATION; WATER CLOSETS 1.6 GALLONS PER FLUSH, SINKS AND SHOWERHEADS 3 GALLONS PER MINUTE. UPC CH.15 W/LOCAL MODIFICATIONS. 2. NOTE ON PLANS THAT SHOWER AND TUB / SHOWER COMBINATIONS THAT HAVE INDIVIDUAL CONTROL VALVES SHALL BE OF THE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE. PER. U.P.C. 410.7 MECHANICAL 1. SHOW EXHAUST FAN LOCATIONS FOR LAUNDRY ROOMS IN LIEU OF OPERABLE WINDOWS. UBC SEC 1203 2. GAS APPLIANCES SHALL COMPLY WITH UMC CH.7 COMBUSTION AIR REQUIREMENTS. DETAIL HOW THIS IS ACHIEVED.-------MIN. 100 SQ.IN. EACH ELECTRICAL 1. DESIGNATE THE LOCATION OF ALL REQUIRED LIGHT FIXTURES, RECEPTACLE OUTLETS, POWER OUTLETS AND SWITCHES.---MISSING FOR RANGE[GAS AND ELECTRIC], RANGE HOOD, DISPOSAL, SWITCH AT DOOR, ETC. 2. AT LEAST ONE WALL SWITCH CONTROLLED LIGHT OR OUTLET MUST BE PROVIDED IN BATHROOMS, HALLWAYS, STAIRWAYS, ATTACHED GARAGES, OUTDOOR ENTRANCES OR EXITS AND ALL HABITABLE ROOMS. (N.E.C. ART.210-70.) 3. RECEPTACLE OUTLETS SHALL BE PROVIDED AT EACH KITCHEN COUNTER SPACE WIDER THAN 12 INCHES AND SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL LINE IS MORE THAN 24 INCHES FROM A RECEPTACLE OUTLET. (N.E.C. ART. 210-52(c)(1).) G.F.C.I. PROTECTION REQUIRED. 4. ISLAND OR PENINSULA COUNTER TOPS SHALL HAVE AT LEAST ONE RECEPTACLE OUTLET AT EACH COUNTER SPACE WITH A LONG DIMENSION OF 24 IN OR GREATER AND A SHORT DIMENSION OF 12 IN OR GREATER.( N.E.C ART.210-52(c)(2)(3)& EXCEPTION.) G.F.C.I. PROTECTION REQUIRED. 5. A RECEPTACLE OUTLET SHALL BE PROVIDED ADJACENT TO THE BASIN IN EACH BATHROOM. (N.E.C. ART.210-52). BATHROOM OUTLETS SHALL BE ON A SEPARATE 20 AMP CIRCUIT WITH NO OTHER OUTLETS (NEC ART. 210-52(d)). G.F.C.I. PROTECTION REQUIRED. 6. INDICATE THE LOCATION OF ALL AIR CONDITIONING AND HEATING UNITS, AIR HANDLERS, COMPRESSORS AND DISCONNECTS.------MISSING FOR COOLER MISCELLANEOUS 1. PROVIDE MODEL ENERGY CALCULATIONS. 2. CALL OUT ON THE PLANS THE R-VALUES OF INSULATION, AS WELL AS THE U-VALUES OF THE WINDOWS IN CONFORMANCE WITH THE M.E.C. CALC'S PROVIDED. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: TERRY STEVENS: @ 791-5550 EXT. 112 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/23/2000 | TAMI ACHONG | APPROVAL SHELF | Completed |
| 10/23/2000 | TAMI ACHONG | OUT TO CUSTOMER | Completed |
| 10/23/2000 | TAMI ACHONG | REJECT SHELF | Completed |