Plan Review Detail
Review Status: Completed
Review Details: REVISION - TENTATIVE PLAT REVIEW
Plan Number - S99-060
Review Name: REVISION - TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/02/2005 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 02/07/2005 | LAITH ALSHAMI | ENGINEERING | REVIEW | Approv-Cond | Laith Alshami, Engineering and Floodplain Review, 02/07/2005 SUBJECT: La Estancia S99-060, T15S, R15E, SECTION 18 RECEIVED: Landscape Plan on February 02, 2005 The subject submittal has been reviewed. The Landscape Plan is recommended for approval pertaining to Engineering and Floodplain subject to the following: 1. Ensure that proposed trees and plants will not obstruct any detention/retention basin inlets, outlets and/or maintenance access ramps. 2. Ensure that proposed trees and plants will not obstruct any sight visibility triangles. |
| 02/16/2005 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 02/18/2005 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Denied | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT S99-060 La Estancia 02/17/05 (x) Tentative Plat () Development Plan (x) Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other CROSS REFERENCE: La Estancia PAD NEIGHBORHOOD PLAN: La Estancia PAD & Rincon/Southeast S.P. GATEWAY/SCENIC ROUTE: N/A COMMENTS DUE BY: February 15, 2005 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies With Plan Policies () See Additional Comments Attached () No Additional Comments - Complies With Planning Comments Submitted on: (x) Resubmittal Required: (x) Tentative Plat () Development Plan (x) Landscape Plan () Other REVIEWER: E. Anderson 791-4505 DATE: 02/08/05 Department of Urban Planning and Design Comments La Estancia s99-060 – 1st submittal 1. Please show the revised PAD block/circulation layout on the appropriate sheets. Please rename “Street J” to Via Rio Pico. 2. The revised land use map shows the El Paso Gasline Park extending north of Via Rio Pico. Please show the required park, with the appropriate path, landscape, seating, and seeding. 3. Please locate an enhanced pedestrian/bicycle crossing at Via Rio Pico along the El Paso Gaseline Park and at the intersection of the minor collector that stems from the village commercial area. This can be accomplished with paving and/or coloring. 4. The submitted plans show landscape up to and in the Via Rio Pico ROW. To review the proposed landscape along Via Rio Pico, which is defined as a secondary streetscape, the drawings need to be to scale. In addition, the vegetation along this street need to conform to the Secondary Streetscapes section (II.D.4). Please show these requirements. 5. The location of common area along this portion of Via Rio Pico provides opportunity to have passive recreation amenities including, but not limited to shaded sitting and resting areas along the sidewalk and bike lane. Please provide at minimum, enhanced shaded sitting and resting areas along this portion of Via Rio Pico. The passive recreation amenity needs to be integrated with the required vegetation along the secondary streetscape. 6. Please show the proper cross-section for Via Rio Pico (Exhibit II.B.1 Industrial Collector Road). Via Rio Pico must have left turn lanes at all local streets and project driveways/ entries. (II.B.c). This includes the minor collector street that stems from the village commercial area. 7. Show and label the boundaries of the appropriate Approach Departure Corridor (ADC) for Davis Monthan Air Force Base on the development plan. Note on the development plan the performance criteria and prohibited uses within the applicable corridor. (ordinance no. 10073) 8. Show and label the boundaries of the appropriate Noise Control District (NCD) for Davis Monthan Air Force Base on the development plan. Note on the development plan the performance criteria and prohibited uses within the applicable district. (ordinance no. 10073) |
| 03/01/2005 | CRAIG GROSS | ZONING-DECISION LETTER | REVIEW | Completed | |
| 03/01/2005 | PETER MCLAUGHLIN | ZONING | REVIEW | Passed |