Plan Review Detail
Review Status: Active
Review Details: FINAL PLAT - REVIEW
Plan Number - S22-061
Review Name: FINAL PLAT - REVIEW
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/06/2022 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 10/06/2022 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Reqs Change | To: Applicant From: Planning & Development Services Dept. Contact Tucson Water to request a Water Availability letter. Include the Letter in your next submittal. This is required before the Mayor and Council can grant their approval. |
| 10/06/2022 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Active | |
| 10/06/2022 | ANY | ZONING-DECISION LETTER | REVIEW | Active | |
| 10/06/2022 | SBEASLE1 | PIMA COUNTY | WASTEWATER | Reqs Change | To: Applicant From: Planning & Development Services Dept. Contact Pima County Wastewater by email: Sewer@Pima.gov, or phone 520-724-6500 to request their approval. Submit the approval letter to the City of Tucson with your next submittal. It is required before the Mayor and Council will grant their approval. |
| 10/06/2022 | SBEASLE1 | UTILITIES | SOUTHWEST GAS | Passed | |
| 10/06/2022 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Active | |
| 10/06/2022 | ANY | PIMA COUNTY | ADDRESSING | Active | |
| 10/17/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL FROM: PDSD Zoning Review PROJECT: Arroyo at Los Reales, Lots 1 - 5 FINAL PLAT (1st Review) S22-061 TRANSMITTAL DATE: October 17, 2022 DUE DATE: October 17, 2022 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 2-07.1.0 APPLICABILITY Final plats, block plats, minor subdivisions, and condominium plats shall be prepared according to the requirements provided below. Hereafter referred to as “plat” or “plats.” A final plat serves as a survey document suitable for recordation of all or part of an approved tentative plat, if applicable. The final plat must conform to the approved tentative plat or site plan in lot configuration, design, and required conditions of development. The final plat, once approved, is recorded in the Pima County Recorder’s Office. The final plat is kept on file and becomes part of the permanent record for the subject site. 2-07.5.0 CONTENT REQUIREMENTS 2-07.5.1 General 1. COMMENT: 2-07.5.1.E.1 – The title block talks about 5 lots, the “KEYMAP” on sheet 1 only shows 4 lots, sheet 4 calls out lot 4 as the proposed street and DP22-0248 calls the street a “FUTURE PUBLIC R/W”. If the proposed street is to be a public right-of-way it should not be called out as a lot on the final plat. Clarify what you are proposing. 2. COMMENT: 2-07.5.1.E.3 – The reference to “’RESUBDIVISION OF LOT 12 OF BLOCK 4 OF SPEEDWAY VIEW ADDITION RECORED IN BOOK 3 OF MAPS AND PLATS 107” does not appear to be correct as the most recent plat recorded under Seq # 20193080883 shows the main parcel as lot 2. 3. COMMENT: 2-07.5.1.H – Provide the subdivision case number, S22-061, adjacent to the title block on all sheets. 2-07.5.2 General Notes The plat must include the following general notes. Additional notes specific to each project are required when pertinent. Fill in the blanks with the project-specific information. 4. COMMENT: 2-07.5.2.A – The acreage listed under General note 1 is not readable. 2-07.5.3 Standard Paragraphs The plat must include the following statements, as applicable. All signatures must be in permanent, black, India ink and be accompanied by a notary signature and seal. 5. COMMENT: 2-07.5.3.D - The City Clerks name provided in the approval block is not correct. If you have any questions about this transmittal, please contact Nicholas Ross at Nocholas.Ross@tucsonaz.gov. To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp |
| 10/19/2022 | SBLOOD1 | ENGINEERING | REVIEW | Reqs Change | 1. Title block description of the final plat doesn't look to be right. 2. The city clerk needs to be corrected. 3. Make sure all the easements shown on the final plat match what is found in the title report. 4. Please provide all instruments/documentation by which any abandoned easements/CC&Rs are abandoned. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |