Plan Review Detail
Review Status: Completed
Review Details: LOT SPLIT REVIEW
Plan Number - S22-052
Review Name: LOT SPLIT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/23/2022 | SBEASLE1 | START | PLANS BEING WALKED THRU | Completed | |
| 10/06/2022 | SBEASLE1 | ZONING-RECORDATION | REVIEW | Reqs Change | email from: COTDSDPermits To: Scott Harlow 10/06/2022 LAND SPLIT PLAN Returned for Corrections: S22-052 DESCRIPTION: LAND SPLIT - Split one parcel into two parcels, one with existing triplex, one with single unit. 515, 517, and 519 West Oury Street. FEE BALANCE: $0 (zero) Thank you for the payment. VIEW COMMENTS AND DOCUMENTS on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on the blue tab - Reviews section - click on REVIEW DETAILS - Documents section - click on VIEW YOUR NEXT STEPS Submit the following items to the FILEDROP 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Survey or Exhibit (even if no changes were made) 3) Legal Descriptions 4) Any other items requested by reviewers FILEDROP https://docs.tucsonaz.gov/Forms/tucsonpermitapp 1. Select "Existing Application" 2. "Permit Number" field: enter your number and any notes you want directed to the City staff Thank you. Sharon Beasley, Certified Permit Specialist City of Tucson, Planning & Development Services Dept. Email: COTDSDpermits@TucsonAz.gov |
| 10/06/2022 | PAUL CAMARENA | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: 515 W Oury St S22-052 Land Split (2nd Review) TRANSMITTAL DATE: October 6, 20222 SECTION 2-08.0.0: LAND SPLIT 2-08.5.0 CONTENT REQUIREMENTS 1.COMMENT: Label the distance and bearings on the record of survey. For (Thence S 25 50 03 E along said east, a distance of 81ft) These comments are still applicable. For the shed structure. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). At a minimum, a neighbor’s setback waiver is required to reduce the perimeter yard setback. To secure this waiver the following text shall be provided on the plot plan and be signed and dated by the owner of the property: My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ If you are unable to secure the neighbor’s setback waiver a Design Development Option (DDO) will need to be processed and approved to reduce the setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov. 2. COMMENT: 2-08.5.F - Provide perimeter yard setback dimensions from all existing structures, i.e. residence, sheds etc., to the proposed property lines. Required perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). If any of the proposed setbacks to not meet the minimum additional comments maybe forth coming. Provide the Lot coverage calculation on the survey. 3. COMMENT: 2-08.5.G - Provide a lot coverage calculation that meets the UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf, for both proposed lots. If you have any questions about this transmittal, Contact Paul Camarena at (520) 837-4986 or by email Paul.Camarena@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat. |