Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Plan Number: S22-050
Parcel: Unknown

Address:
839 E MINORKA RD

Review Status: Active

Review Details: MINOR SUBDIVISION REVIEW

Plan Number - S22-050
Review Name: MINOR SUBDIVISION REVIEW
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
10/06/2022 SBEASLE1 START PLANS SUBMITTED Completed
10/06/2022 ANY LANDSCAPE REVIEW Active
10/06/2022 SBEASLE1 PIMA COUNTY WASTEWATER Reqs Change To: Applicant
From: Planning & Development Services Dept.

Contact Pima County Wastewater by email: Sewer@Pima.gov, or phone 520-724-6500 to request their approval. Submit the approval letter to the City of Tucson with your next submittal. It is required before the Mayor and Council will grant their approval.
10/06/2022 SBEASLE1 UTILITIES SOUTHWEST GAS Passed
10/06/2022 JIM EGAN COT NON-DSD FIRE Active
10/06/2022 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Reqs Change To: Applicant
From: Planning & Development Services Dept.

Contact Tucson Water to request a Water Availability letter. Include the Letter in your next submittal. This is required before the Mayor and Council can grant their approval.
10/06/2022 SBEASLE1 OTHER AGENCIES U. S. POST OFFICE Passed
10/06/2022 ANY UTILITIES TUCSON ELECTRIC POWER Active
10/06/2022 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Active
10/06/2022 ED ABRIGO PIMA COUNTY ASSESSOR Active
10/06/2022 SBEASLE1 OTHER AGENCIES PIMA ASSN OF GOVTS Passed
10/06/2022 KAY MARKS PIMA COUNTY ADDRESSING Active
10/06/2022 ANY ZONING-DECISION LETTER WRITE DECISION LETTER Active
10/11/2022 SBLOOD1 ENGINEERING REVIEW Reqs Change 1. The approval block needs to be updated, the city clerk needs to be Suzanne Mesich and the instrument was filed at the request of Ashes Investment LP which is different from the dedication of Minorka Partners LLC. Revise as needed.
2. Identify what the property corners are, either found monumentation or set, and label the set monumentation.
3. The Basis of Bearing uses Minorka Rd, and needs to show 2 separate found monumentation to establish it per city code.
4. Include a label to locate this subdivision in the location map.
5. Please include in the next submittal a copy of the title report.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
10/13/2022 ROBERT SHERRY PLUMBING-RESIDENTIAL REVIEW Completed
10/17/2022 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Minorka Subdivision, Lots 1 - 3
FINAL PLAT (1st Review)
S22-050

TRANSMITTAL DATE: October 17, 2022

DUE DATE: October 14, 2022

COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.
2-07.1.0 APPLICABILITY
Final plats, block plats, minor subdivisions, and condominium plats shall be prepared according to the requirements provided below. Hereafter referred to as “plat” or “plats.”
A final plat serves as a survey document suitable for recordation of all or part of an approved tentative plat, if applicable. The final plat must conform to the approved tentative plat or site plan in lot configuration, design, and required conditions of development. The final plat, once approved, is recorded in the Pima County Recorder’s Office. The final plat is kept on file and becomes part of the permanent record for the subject site.
2-07.4.0 FORMAT REQUIREMENTS
1. COMMENT: 2-07.4.4 – Provide the scale of the plat on the plan.
2-07.5.0 CONTENT REQUIREMENTS
2-07.5.1 General
2. COMMENT: 2-07.5.1.A.1 – Clearly show the project site approximately centered within a one square mile area of the location map.

3. COMMENT: 2-07.5.1.A.2 – The section corners labeled on the location map are not correct.
2-07.5.3 Standard Paragraphs
The plat must include the following statements, as applicable. All signatures must be in permanent, black, India ink and be accompanied by a notary signature and seal.
4. COMMENT: 2-07.5.3.D - The City Clerks name provided in the approval block is not correct.
Additional comments:
5. As no permits have been issued for development of lots 1 & 3 remove all development from these lots on the provided site plan.

6. Provide a lot coverage calculation that meets the requirements of UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf, for lot 2 on the provided site plan.
If you have any questions about this transmittal, please contact Nicholas Ross at Nocholas.Ross@tucsonaz.gov.
To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp
10/18/2022 SBEASLE1 COT NON-DSD PARKS & RECREATION Approved email from: Howard Dutt
to: CDRC
10/17/2022

No existing or proposed Tucson Parks and Recreation facilities are affected by this Minor Subdivision/Final Plat.

Howard Dutt, RLA
Project Manager/Landscape Architect

Parks and Recreation | City of Tucson
Howard.Dutt@tucsonaz.gov
main 520.631.2030
10/19/2022 JOSE ORTIZ COT NON-DSD TRAFFIC Approved