Plan Number: S22-031
Parcel: Unknown

Address:
1132 N 6TH AV

Review Status: Completed

Review Details: LOT SPLIT REVIEW

Plan Number - S22-031
Review Name: LOT SPLIT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/27/2022 SBEASLE1 START PLANS BEING WALKED THRU Completed
06/28/2022 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Tucson Water has approved this land split but will require a water main extension to provide water service to parcel B. Show the easement for the water main extension. [Initial comment: For the purposes of having a water meter, a parcel is required to have a minimum width of 15-feet of frontage on a water main. An easement is not considered to be frontage. Show how parcel B will be provided with a water meter. Reference: Tucson Water Remote Meter Policy, Number IV-B.08, dated 07/14/2009.]
06/29/2022 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: 1132 N 6th Ave – C-2
S22-031
Land Split (2nd Review)

TRANSMITTAL DATE: June 29, 2022

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.
SECTION 2-08.0.0: LAND SPLIT

2-08.3.0 APPLICATION SUBMITTAL REQUIREMENTS
1. COMMENT: 2-08.3.7 –
Parcel ‘A’ Description:
a. Line 11 the bearing does not match what is shown on the plan.
b. Line 15 the distance does not match what is shown on the plan.
Parcel ‘B’ Description:
a. Line 21 the distance does not match what is shown on the plan.

2-08.5.0 CONTENT REQUIREMENTS
2. COMMENT: 2-08.5.D – The drawing now shows 2 easements running across Parcel ‘A’: 1 sewer easement along the north property line and one water easement along the south property line. These easements run under existing structures on the site. Provide written permission from Pima County Waste Water and Tucson Water that allows these easements to run under the structures.

3. This comment was not addressed. COMMENT: 2-08.5.H – Demonstrate how legal access will be provided to both parcels. If alley access is proposed demonstrate how the requirements of UDC Article 7.4.6.K.2 are met. If access for Parcel A will be provided from the alley some type of easement is required.

If you have any questions about this transmittal, please contact Nicholas Ross at Nicholas.Ross@tucsonaz.gov.
07/14/2022 JGARCIA1 BUILDING-COMMERCIAL REVIEW Reqs Change 1. General: Indicate how access to each parcel is achieved.
08/19/2022 SBLOOD1 ENGINEERING REVIEW Reqs Change 1. Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Engineering Review Section comments were addressed.
2. Show vehicle access locations for both proposed parcels.
3. Show vehicle use areas for parcel A.
4. Clearly identify the use of each existing building.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
08/22/2022 SBEASLE1 ZONING-RECORDATION REVIEW Reqs Change Email from: COTDSDPermits
To: Jeff Stephens
08/22/2022

LAND SPLIT PLAN
Returned for Corrections: S22-031

Project Description: Land Split - Phillips Subdivision. Divide one parcel into two parcels.
1132 N 6TH AV

Fee Balance: $0 (zero) Thank you for the payment.

View the review comments and documents on PRO:
www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

YOUR NEXT STEPS
Submit the following items to the FILEDROP
1) Comment Response Letter (your response to the reviewer's Requires Change comments)
2) Survey or Exhibit (even if no changes were made)
3) Legal Descriptions
4) Any other items requested by reviewers

FILEDROP
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
1. Select "Existing Application"
2. "Permit Number" field: enter your number and any notes you want directed to the City staff


Thank you.
Sharon Beasley, Certified Permit Technician

City of Tucson, Planning & Development Services Dept.
Email: COTDSDpermits@TucsonAz.gov
(for land splits, development packages, Thursday Presubmittal meetings)
Email: PDSDinquiries@TucsonAz.gov
(for building permits)