Plan Review Detail
Review Status: Completed
Review Details: FINAL PLAT - REVIEW
Plan Number - S22-030
Review Name: FINAL PLAT - REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/02/2022 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 06/02/2022 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Reqs Change | To: Applicant From: Planning & Development Services Dept. Contact Tucson Water to request a Water Availability letter. Include the Letter in your next submittal. This is required before the final step of Mayor and Council's approval of the FINAL PLAT. |
| 06/02/2022 | SBEASLE1 | UTILITIES | SOUTHWEST GAS | Passed | |
| 06/02/2022 | SBEASLE1 | PIMA COUNTY | WASTEWATER | Reqs Change | To: Applicant From: Planning & Development Services Dept. Contact Pima County Wastewater at email: Sewer@Pima.gov, or phone 520-724-6500 to request their approval. Submit the approval letter to the City of Tucson with your next submittal. It is required before the final step of Mayor and Council's approval of the FINAL PLAT. |
| 06/20/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL FROM: PDSD Zoning Review PROJECT: Crown Estates Lots 1-11 – Final Plat FINAL PLAT (1st Review) S22-030 TRANSMITTAL DATE: June 20, 2022 DUE DATE: June 14, 2022 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 2-07.1.0 APPLICABILITY Final plats, block plats, minor subdivisions, and condominium plats shall be prepared according to the requirements provided below. Hereafter referred to as “plat” or “plats.” A final plat serves as a survey document suitable for recordation of all or part of an approved tentative plat, if applicable. The final plat must conform to the approved tentative plat or site plan in lot configuration, design, and required conditions of development. The final plat, once approved, is recorded in the Pima County Recorder’s Office. The final plat is kept on file and becomes part of the permanent record for the subject site. 2-07.5.0 CONTENT REQUIREMENTS 1. 2-07.5.1.H - The subdivision case number, S22-024 , assigned to this plat must be placed in the lower right corner of the plat next to the title block on all sheets. 2. COMMENT: Until DP21-0336 is approved by all review agencies Zoning cannot approve this plat. If you have any questions about this transmittal, please contact Nicholas Ross at Nocholas.Ross@tucsonaz.gov. To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp |
| 06/27/2022 | SBEASLE1 | PIMA COUNTY | ADDRESSING | Reqs Change | <See plan in DOCUMENTS section of PRO, titled "Pima Co Addressing, first submittal review comments"> Email from: Nicholas Jordan <Nicholas.Jordan@pima.gov> To: CDRC Thu 6/23/2022 3:37 PM Pima County Addressing is returning S22-030 Final plat for Crown Estates Lots 1-11 for corrections. Please see plan for comments. Nicholas Jordan Site Review Project Manager - Addressing Official Pima County Development Services Department 201 N Stone AV – 1st Floor Tucson, AZ 85701 (520) 724-962 |
| 07/12/2022 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | email from: TEP-DEVREV <TEPDEVREV@tep.com> To: CDRC Wed 7/6/2022 3:44 PM Tucson Electric Power Co. (TEP) has reviewed the plans submitted on June 2nd 2022, and has no objections at this time. Additional easements are required for TEP facilities if revisions are needed to the current design. They will need to be obtained by separate instrument. Tucson Electric Power Co. Land Resources Department |
| 07/27/2022 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approved | Approved. View the letter in DOCUMENTS section of PRO, titled "Pima Co Assessors, Approval Letter, 06.02.22" |
| 08/16/2022 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | Email from: COTDSDPermits to: theresa hadley REVIEW NOTICE Returned for Corrections: S22-030 Final Plat - Crown Estates, Lots 1 thru 11. Fee Balance: $0 (zero) YOUR NEXT STEPS 1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews section - click on REVIEW DETAILS - Documents section - click on VIEW 2. Title your SECOND submittal documents accordingly, example: 2_Comment Response Letter 3. UPLOAD A RESUBMITTAL to Filedrop: - Comment Response Letter (your response to REQUIRES CHANGE comments) - Plan Set (all pages, full set, even if no changes were made) - Any other documents requested by review staff FILEDROP https://docs.tucsonaz.gov/Forms/tucsonpermitapp - "Existing Application" - "Permit Number" field: enter the number (and any notes for our staff) - Select "PLANS" for all documents Sharon Beasley, Certified Permit Technician City of Tucson, Planning & Development Services Dept. Email: COTDSDpermits@TucsonAz.gov (for development packages, land splits, Thursday Presubmittal meetings) Email: PDSDinquiries@TucsonAz.gov (for building permits) |
| 08/16/2022 | SBLOOD1 | ENGINEERING | REVIEW | Reqs Change | 1. Please clarify and revise as necessary the easement bounds for both the existing sewer connection agreement per dkt. 412, pg. 163 and existing electric pole and overhead wires easement per dkt. 1165, pg. 46. 2. The tentative plat DP21-0326 needs to be approved before this final plat can be approved. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |