Plan Number: S22-015
Parcel: Unknown

Review Status: Completed

Review Details: FINAL PLAT - REVIEW

Plan Number - S22-015
Review Name: FINAL PLAT - REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/05/2022 SBEASLE1 START PLANS SUBMITTED Completed
09/05/2022 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved View in the DOCUMENTS section of PRO, letter titled: "2_Water Availability Letter, Tucson Water"
09/05/2022 SBEASLE1 PIMA COUNTY WASTEWATER Approved (View the letter in the DOCUMENTS section of PRO, titled: "2_Wastewater Final Plat Approval Letter, Pima County")

Final Plat Approval
Record Number: P22WS00042
Project Name: Pantano Vista, Lots 1 - 32
Approval issue date: 08/17/2022

Applicant: JAS Engineering, Attn. Jeff Stanley
Owner Name: Rocky Brown Oz Estates, Inc
Owner Address: 5901 S Belvedere Ave, Tucson, AZ 85706

The Pima County Development Services Department has reviewed the abovereferenced project and hereby approves the Final Plat, based upon PCRWRD Engineering Design Standards (EDS) 2016.
Please note any changes and/or revisions to the approved plans shall require a re-submittal to the department for review and evaluation.
09/14/2022 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Pantano Vista, Lots 1-32
FINAL PLAT (2nd Review)
S22-015

TRANSMITTAL DATE: September 14, 2022

DUE DATE: September 27, 2022

COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

2-07.1.0 APPLICABILITY
Final plats, block plats, minor subdivisions, and condominium plats shall be prepared according to the requirements provided below. Hereafter referred to as “plat” or “plats.”
A final plat serves as a survey document suitable for recordation of all or part of an approved tentative plat, if applicable. The final plat must conform to the approved tentative plat or site plan in lot configuration, design, and required conditions of development. The final plat, once approved, is recorded in the Pima County Recorder’s Office. The final plat is kept on file and becomes part of the permanent record for the subject site.
2-07.5.6 Protective Covenants
Protective covenants or Covenants, Conditions, and Restrictions (CC&Rs) establishing responsibility for construction, maintenance, and ownership of any proposed common area, open space, private street, or similar joint use, when needed, will:
1. COMMENT: 2-07.5.6 – The provide CC&R’s do not address common area maintenance, insurance or drainage facilities.
If you have any questions about this transmittal, please contact Nicholas Ross at Nocholas.Ross@tucsonaz.gov.
To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp
09/21/2022 SBLOOD1 ENGINEERING REVIEW Reqs Change See zoning comment regarding provided CC&Rs.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
10/04/2022 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change email from: COTDSDPermits
To: Jeffrey Stanley
10/04/2022

REVIEW NOTICE

Returned for Corrections: S22-015
Final Plat - Pantano Vista
8315 E GOLF LINKS RD

Fee Balance: $0 (zero) Thank you for the payment.

YOUR NEXT STEPS
1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on the blue tab
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

2. Title your THIRD submittal documents accordingly, example: 3_Comment Response Letter

3. UPLOAD documents to Filedrop:
- Comment Response Letter (your response to REQUIRES CHANGE comments)
- Plan Set (all pages, full set, even if no changes were made)
- Documents requested by review staff

FILEDROP
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- "Existing Application"
- "Permit Number" field: enter the number (and any notes for our staff)


Sharon Beasley, Certified Permit Specialist

City of Tucson, Planning & Development Services Dept.
Email: COTDSDpermits@TucsonAz.gov
10/04/2022 ED ABRIGO PIMA COUNTY ASSESSOR Reqs Change FROM: Julieann Arechederra, GIS Cartographer
Pima County Assessor's Office

DATE: October 3, 2022

RE: Assessor's Review and Comments Regarding:
PANTANO VISTA S22-015

___X___ Plat does not meet Assessor's Office requirements.

COMMENTS:

" TOWNSHIP, RANGE AND SECTION ON THE TOP RIGHT CORNER AND BOTTON RIGHT CORNER MUST BE THE SAME.
SECTION# ON TOP RIGHT SAYS 24, BOTTON RIGHT SECTION SAYS 21. PLEASE CORRECT TO REFLECT THE SAME.