Plan Number: S22-013
Parcel: Unknown

Address:
3131 S PORTIA AV

Review Status: Completed

Review Details: FINAL PLAT - REVIEW

Plan Number - S22-013
Review Name: FINAL PLAT - REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/20/2022 SBEASLE1 START PLANS SUBMITTED Completed
07/20/2022 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved Approved.
View the letter in DOCUMENTS section of PRO, titled: "2_Tucson Water availability letter, November 2021"
07/29/2022 ED ABRIGO PIMA COUNTY ASSESSOR Reqs Change TO: CDRC Office
Subdivision Review, City of Tucson

FROM: Julieann Arechederra, GIS Cartographer
Pima County Assessor's Office

DATE: July 25, 2022

RE: Assessor's Review and Comments Regarding:
CASAS DEL CERRITO S22-013

___X___ Plat does not meet Assessor's Office requirements.

COMMENTS:

" GENERAL NOTES MUST HAVE THE BASIS OF BEARING.

" THERE MUST BE A SECTION TIE, WITH A BEARING AND DIMENSION FROM THE SECTION CORNER OR QUARTER CORNER TO THE POINT OF TIE ON THE SUBDIVISION.

" THERE MUST BE DIMENSIONS FOR THE PERIMETER AND ALL LOT LINES AND ALL COMMON AREAS. COMMON AREA "A"(BASIN) NEEDS DISTANCE AND BEARINGS ON THE NORTH AND WEST LINES OF THE LOT.

" ALL LOTS MUST BE NUMBERED AND HAVE SQUARE FOOTAGE. COMMON AREA "A" NEEDS SQUARE FOOTAGE.

" ALL ADJACENT SUBDIVISIONS SHOULD BE NAMED, WITH MAP AND PLAT IN THE APPROPRIATE AREAS AROUND THE SUBDIVISION.

" OWNERSHIP MUST MATCH PLAT'S OWENERSHIP AND THE DEED NEEDS TO BE RECORDED PRIOR TO RECORDING OF PLAT. OUR RECORDS SHOW TUCSON UNIFIED SCHOOL DISTRICT 1 AS OWNING THIS PROPERTY.
08/05/2022 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Casas Del Cerrito, Lots 1-49
FINAL PLAT (2nd Review)
S22-013

TRANSMITTAL DATE: August 5, 2022

DUE DATE: August 11, 2022

This comment was not addressed. COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

2-07.1.0 APPLICABILITY
Final plats, block plats, minor subdivisions, and condominium plats shall be prepared according to the requirements provided below. Hereafter referred to as “plat” or “plats.”
A final plat serves as a survey document suitable for recordation of all or part of an approved tentative plat, if applicable. The final plat must conform to the approved tentative plat or site plan in lot configuration, design, and required conditions of development. The final plat, once approved, is recorded in the Pima County Recorder’s Office. The final plat is kept on file and becomes part of the permanent record for the subject site.
2-07.5.0 CONTENT REQUIREMENTS
2-07.5.1 General
1. This comment was not addressed. COMMENT: 2-07.5.2 General Notes – Review this section and provide only the required notes on the plat. Remove such notes as dimensional standards, etc/

If you have any questions about this transmittal, please contact Nicholas Ross at Nocholas.Ross@tucsonaz.gov.
To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp
RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat & detailed response letter.
visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp
09/01/2022 SBLOOD1 ENGINEERING REVIEW Reqs Change 1. See previous comment 3 - Include the Basis of Bearing Statement on the Plat.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
09/02/2022 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change EMAIL FROM: COTDSDPermits
To: Nate Gardner
cc: K. Burruel
09/02/2022

Returned for Corrections: S22-013
Final Plat - Casas Del Cerrito, Lots 1 thru 49, and Common Areas "A" and "B". Single-story homes.
3131 S PORTIA AV

Fee Balance: $0 (zero) Thank you for the payment.

YOUR NEXT STEPS
1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

2. Title your THIRD submittal documents accordingly, example: 3_Comment Response Letter

3. UPLOAD documents to Filedrop:
- Comment Response Letter (your response to REQUIRES CHANGE comments)
- Plan Set (all pages, full set, even if no changes were made)
- Documents requested by review staff

FILEDROP
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- "Existing Application"
- "Permit Number" field: enter the number (and any notes for our staff)


Sharon Beasley, Certified Permit Technician

City of Tucson, Planning & Development Services Dept.
Email: COTDSDpermits@TucsonAz.gov
(for development packages, land splits, Thursday Presubmittal meetings)
Email: PDSDinquiries@TucsonAz.gov
(for building permits)
09/02/2022 SBEASLE1 PIMA COUNTY WASTEWATER Reqs Change To: Applicant
From: Planning & Development Services Dept.

Contact Pima County Wastewater at email: Sewer@Pima.gov, or phone 520-724-6500 to request their approval. Submit the approval letter to the City of Tucson with your next submittal. It is required before the final step of Mayor and Council's approval of the FINAL PLAT.