Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Plan Number: S21-068
Parcel: Unknown

Address:
355 S CONVENT AV

Review Status: Completed

Review Details: LOT SPLIT REVIEW

Plan Number - S21-068
Review Name: LOT SPLIT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/22/2021 SBEASLE1 START PLANS BEING WALKED THRU Completed
09/22/2021 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
09/23/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: 92 W Simpson St. – HO-3
S21-068
Land Split (1st Review)

TRANSMITTAL DATE: September 23, 2021

SECTION 2-08.0.0: LAND SPLIT

2-08.5.0 CONTENT REQUIREMENTS
1. COMMENT: 2-08.5.F – Per TABLE 6.3-3.A: DIMENSIONAL STANDARDS FOR THE O-1, O-2, & O-3 ZONES, O-3 Zone, residential use to nonresidential zone the required perimeter yard setback is the greater of 10’-0” or 3/4 the height of the exterior wall. Provide a setback dimension from the post supporting the porch to the west property line of Parcel 2. As the house and porch do not meet the minimum setback to the proposed property line, at a minimum a Design Development Option (DDO) will need to be processed for reduced perimeter yard setbacks. Depending on how comment 2 is addressed the reduced perimeter yard setbacks can be processed in the required Board of Adjustment.

2. COMMENT: 2-08.5.F – Per TABLE 6.3-3.A: DIMENSIONAL STANDARDS FOR THE O-1, O-2, & O-3 ZONES, O-3 Zone, the minimum lot size for a residential use is 5,000 sq. ft. Proposed lot size of Parcel 2 is 3379.5 sq. ft. At a minimum a Board of Adjustment for Variance is required to reduce the lot size below minimum requirements. Board of Adjustment application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/codes/Zoning_Administration_Application_BA_fillable.pdf. The Board of Adjustment is a separate submitted from the land split and is submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the submission type “Zoning Administration”. Contact Mark Castro at Mark.Castro@tucsonaz.gov for questions about the Board of Adjustment.

3. COMMENT: 2-08.5.G – Provide a lot coverage calculation for both parcels. The lot coverage calculation shall meet the requirements of UDC Article 6.4.3 and the example shown on the Residential Plot Plan requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov
09/23/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
10/22/2021 SBEASLE1 ZONING-RECORDATION REVIEW Reqs Change Email from: COTDSDPermits
To: Dusty Delrio
Fri 10/22/2021 3:44 PM

LAND SPLIT PLAN
Returned for Corrections: S21-068

Description: Land Split - White/Treadway. Reconfigure lot line, parcels 1 and 2. 92 W SIMPSON ST

FEE Balance: credit -$82.50
FEE Refund Request form:
https://www.tucsonaz.gov/files/pdsd/Request_for_Refund_of_Permit_Fees.pdf
-If any refund questions, call the Permit Counter staff at (520) 791-5550, or send email to: PDSDinquiries@TucsonAz.gov
----------------------------------------

View the review comments and documents on PRO:
www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab and you will see different sections
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

YOUR NEXT STEPS
Submit the following items to the FILEDROP
1) Comment Response Letter (your response to the reviewer's Requires Change comments)
2) Survey or Exhibit (even if no changes were made)
3) Legal Descriptions
4) Any other items requested by reviewers

FILEDROP
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
Select "Existing Application", then in the "Permit Number" field, enter your number and any notes you want directed to the City staff

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson, Planning & Development Services Dept.
Email: COTDSDpermits@TucsonAz.gov
(disregard the email response that will be sent automatically)
10/22/2021 LOREN MAKUS ENGINEERING REVIEW Reqs Change See zoning comments.
10/22/2021 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved Email from: Jeremiah Jenkins
To: CDRC
Fri 10/22/2021 2:01 PM

Tucson Water approves of the split.
Thank you,

Jeremiah Jenkins, Water Services Supervisor
City of Tucson Water Department,
New Services
201 N Stone Ave, First Floor
Public Counter hours: Mon-Thur 8am to 4pm
Department Hours: Mon-Fri 8am to 4pm
Office: 520-791-5164