Plan Number: S21-067
Parcel: Unknown

Review Status: Completed

Review Details: LOT SPLIT REVIEW

Plan Number - S21-067
Review Name: LOT SPLIT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/21/2021 SBEASLE1 START PLANS BEING WALKED THRU Completed
09/22/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: 120 N Longfellow Ave
S21-067
Land Split (1st Review)

TRANSMITTAL DATE: September 22, 2021

SECTION 2-08.0.0: LAND SPLIT

2-08.5.0 CONTENT REQUIREMENTS
1. COMMENT: 2-08.5.A – Both legal descriptions for the east parcel line of Lot A show a distance of 147.77 and the plan shows 147.33, clarify which is correct.

2. COMMENT: 2-08.5.A – Legal description for Lot B shows the distance for the west parcel line of Lot B to be 122.23 but when you add up the two distances shown on the plan it equals 122.24, clarify which is correct.

3. COMMENT: 2-08.5.F – Provide a perimeter yard setback dimension form the northwest corner of Lot B to the existing structure. Per UDC TABLE 6.3-2.A: DIMENSIONAL STANDARDS FOR THE R-1, R-2, R-3, MH-1, & MH-2 ZONES, R-1 Zone, residential use to residential zone the required perimeter yard setback is the greater of 6’-0” or 2/3 the height of the exterior wall. Also, provide a wall height as measured from design grade to the highest point of the wall that is closest to the northwest corner of Lot B.

4. COMMENT: 2-08.5.G – Provide a lot coverage calculation for proposed Lot A. The lot coverage calculation shall meet the requirements of UDC Article 6.4.3 and the example shown on the Residential Plot Plan requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov
09/22/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
09/27/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Provide a site plan showing distance of buildings from the proposed property line with fire separation compliance, 2018 IRC R302.1.
10/22/2021 LOREN MAKUS ENGINEERING REVIEW Reqs Change Ensure the legal description and site plan are consistent. See zoning comments.
10/22/2021 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved Email from: Jeremiah Jenkins
To: CDRC
Fri 10/22/2021 2:06 PM

Tucson Water approves of the split.
Thank you,

Jeremiah Jenkins, Water Services Supervisor
City of Tucson Water Department,
New Services
201 N Stone Ave, First Floor
Public Counter hours: Mon-Thur 8am to 4pm
Department Hours: Mon-Fri 8am to 4pm
Office: 520-791-5164
10/22/2021 SBEASLE1 ZONING-RECORDATION REVIEW Reqs Change Email from: COTDSDPermits
To: Ken Smalley
Fri 10/22/2021 3:00 PM

LAND SPLIT PLAN
Returned for Corrections: S21-067

Description: Land Split / Reconfiguration - Colonial Estates. 120 N LONGFELLOW AV

FEES DUE: $99.00
ONLINE PAYMENTS
https://www.tucsonaz.gov/pdsd/fees
If amount doesn't match "Fees Due", check back in a few hours after it is updated.
1- Click on: Pay Planning & Permit Fees
2- Enter your Permit Nbr, example: dp20-0000
(not case-sensitive but a hyphen-dash- is needed)
3- Business/Individual Name: Leave blank
4- Click "Continue"
5-Under the Pay column, check the boxes you want to pay
6- Click "Continue", then enter your credit card info

View the review comments and documents on PRO:
www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab and you will see different sections
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

YOUR NEXT STEPS
Submit the following items to the FILEDROP
1) Comment Response Letter (your response to the reviewer's Requires Change comments)
2) Survey or Exhibit (even if no changes were made)
3) Legal Descriptions
4) Any other items requested by reviewers

FILEDROP
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
Select "Existing Application", then in the "Permit Number" field, enter your number and any notes you want directed to the City staff

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson, Planning & Development Services Dept.
Email: COTDSDpermits@TucsonAz.gov
(disregard the email response that will be sent automatically)