Plan Review Detail
Review Status: Completed
Review Details: FINAL PLAT - REVIEW
Plan Number - S21-057
Review Name: FINAL PLAT - REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/23/2021 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 08/23/2021 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Reqs Change | To: Applicant From: City of Tucson Please contact Tucson Water to request a Water Availability letter. Include the Letter in your next submittal. Mayor and Council cannot grant final approval for this Final Plat until water is assured and available. |
| 08/23/2021 | SBEASLE1 | UTILITIES | SOUTHWEST GAS | Passed | |
| 08/23/2021 | SBEASLE1 | PIMA COUNTY | WASTEWATER | Reqs Change | To: Applicant From: City of Tucson Please contact Pima County Wastewater (email: Sewer@Pima.gov, phone 520-724-6500) and request approval. Include the Pima Co WW approval document in your next submittal. This will be required before the last step of Mayor and Council's final approval. |
| 09/09/2021 | STEVE SHIELDS | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL FROM: PDSD Zoning Review PROJECT: Bella Tierra Phase 3 Lots 1-78 FINAL PLAT (1st Review) S21-057 TRANSMITTAL DATE: September 9, 2021 DUE DATE: September 16, 2021 The Zoning Review Section conditionally approves the final plat for this project subject to the comment below. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements. 2-07.5.0 CONTENT REQUIREMENTS 2-07.5.1.H – Provide the following case numbers, S20-057 & DP21-0060, in the lower right corner of the plat next to the title block on all sheets. If you have any questions about this transmittal, please contact Elisa Hamblin or Elisa.Hamblin@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Final Plat |
| 09/14/2021 | SBEASLE1 | PIMA COUNTY | ADDRESSING | Reqs Change | (The entire email with the image can be viewed in the "Documents" section of PRO, titled "Pima Co Addressing, review comments, 09.13.21".) Email from: <Addressing@pima.gov> To: CDRC Mon 9/13/2021 11:17 AM Bella Tierra, S21-057, is Approved by Pima County Addressing conditional upon the correct project numbers being updated in the Title Block as follows: Thank you, Robin Freiman, Addressing Official Pima County Development Services Department 201 N Stone AV – 1st Floor Tucson, AZ 85701 (520) 724-7570 |
| 09/20/2021 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | Email from: TEP-DEVREV <TEPDEVREV@tep.com> To: CDRC Sun 9/19/2021 10:48 AM Tucson Electric Power Co. (TEP) has reviewed and has no objection to the Bella Tierra, S21-057, Blocks 1-2, submitted on August 23rd, 2021. Please note TEP will not install facilities until the plat and any other land rights have not been recorded and contracts have been executed and received. If removal or relocation of existing TEP facilities is required for this project, the developer will be responsible for any and all costs associated with such work. Easements for TEP facilities, as identified on the Preliminary Drawing, must be shown on the final plat and provided to TEP for review prior to submittal for approval. Please note a Jurisdictional permit for any work done on Camino Seco Rd, Linderbrook Dr.,or Wingate. Should you have any easement questions, don't hesitate to get in touch with TEPDEVREV@TEP.COM Diane Geerligs Tucson Electric Power |
| 09/29/2021 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approved | (See full document in "Documents" section of PRO: "Pima Co Assessors approval letter, 09.27.21") FROM: Julieann Arechederra, GIS Cartographer Pima County Assessor’s Office DATE: September 27, 2021 RE: Assessor’s Review and Comments Regarding: BELLA TIERRA PHASE 3 S21-057 X Plat meets Assessor’s Office requirements. |
| 10/12/2021 | SBLOOD1 | ENGINEERING | REVIEW | Approved | |
| 10/13/2021 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | Email from: COTDSDPermits To: C. Thompson Wed 10/13/2021 2:49 PM Returned for Corrections: S21-057 DESCRIPTION: Final Plat/FLD - Bella Tierra, 4855 S WINGATE BL Fee Balance: $0 (zero) Thank you for the payment. REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab and you will see different sections - Reviews section - click on REVIEW DETAILS - Documents section - click on VIEW INCLUDE IN RESUBMITTAL 1) Comment Response Letter (your response to any Requires Change comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff Please title your SECOND submittal documents according to this example: 2_Comment Response Letter FILEDROP for Resubmittal https://docs.tucsonaz.gov/Forms/tucsonpermitapp - Select "Existing Application" - In the "Permit Number" field, enter the number and, if applicable, any notes for our staff Thank you. Sharon Beasley, Permit Specialist City of Tucson, Planning and Development Services Email for Development Pkgs: COTDSDpermits@TucsonAz.gov (disregard the email response that will be sent automatically) |