Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S21-056
Parcel: Unknown

Address:
7720 S WILMOT RD

Review Status: Completed

Review Details: FINAL PLAT - REVIEW

Plan Number - S21-056
Review Name: FINAL PLAT - REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/23/2021 SBEASLE1 START PLANS SUBMITTED Completed
11/23/2021 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved (This letter is viewable in the Documents section of PRO: "Water availability letter, Tucson Water, February 2021")

February 4, 2021

SUBJECT: Water Availability for Project: Blackhawk Ranch, APN: 140-44-009D,
Case # WA3401, T-15 R-14 S-24, Lots: 9999, Location Code: TUC: Total Area: 77.3ac, Zoning: SH

WATER SUPPLY
Tucson Water will provide water service to this project based on the subject zoning of the above parcels. Tucson
Water has an assured water supply (AWS) designated from the State of Arizona Department of Water Resources
(ADWR). An AWS designation means Tucson Water has met the criteria established by ADWR for
demonstration of a 100-year water supply - it does not mean that water service is currently available to the subject
project.

WATER SERVICE
The approval of water meter applications is subject to the current availability of water service at the time an
application is received. The developer shall be required to submit a water master plan identifying, but not limited
to: 1) Water Use; 2) Fire Flow Requirements; 3) Offsite/Onsite Water Facilities; 4) Loops and Proposed
Connection Points to Existing Water System; and 5) Easements/Common Areas.

Any specific area plan fees, protected main/facility fees and/or other needed facilities' cost, are to be paid by the
developer. If the existing water system is not capable of meeting the requirements of the proposed development,
the developer shall be financially responsible for modifying or enhancing the existing water system to meet those
needs. This letter shall be null and void two years from the date of issuance.

Issuance of this letter is not to be construed as agency approval of a water plan or as containing
construction review comments relative to conflicts with existing water lines and the proposed development.
If you have any questions, please call New Development at 791-4718.

Sincerely,
Michael Mourreale, Engineering Manager
Tucson Water New Development
11/30/2021 SBEASLE1 ZONING REVIEW Approved Nov. 30, 2021
The two approval conditions of the previous Zoning review have been met (regarding the Final Plat document).

Sharon Beasley, Permit Specialist
City of Tucson
12/01/2021 SBEASLE1 PIMA COUNTY WASTEWATER Approved (This letter can be viewed in the "Documents" section of PRO: "Pima Co Wastewater, Approval Letter, 11.30.21")

Final Plat Approval

Record Number: P21WS00077
Project Name: Blackhawk Lots 1-310
Approval issue date: 11/30/2021
Applicant: The WLB Group. Attn. Linda Thompson
Owner Name: Legacy Collateral Holdings LLC
Owner Address: 20701 N Scottsdale Rd Ste 107 Scottsdale, AZ

The Pima County Development Services Department has reviewed the above referenced project and hereby approves the Final Plat, based upon PCRWRD Engineering Design Standards (EDS) 2016.

Please note any changes and/or revisions to the approved plans shall require a re-submittal to the department for review and evaluation.

www.pima.gov
Pima County Development Services Department
12/14/2021 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
To: Linda Thompson
Tue 12/14/2021 4:42 PM

Returned for Corrections: S21-056

DESCRIPTION:
Final Plat/FLD - Blackhawk, Lots 1 thru 310, Block One, Common Areas "A" (natural undisturbed open space), "B" (landscape, drainage, slope maintenance and access), and "C" (functional open space and recreation). 7720 S WILMOT RD

Fee Balance: $0 (zero) Thank you for the payment.

YOUR NEXT STEPS
1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab to see different sections
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

2. UPLOAD A RESUBMITTAL and include:
1) Comment Response Letter (your response to REQUIRES CHANGE comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

Please title your THIRD submittal documents according to this example: 3_Comment Response Letter

FILEDROP for your Resubmittal
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- Select "Existing Application"
- In the "Permit Number" field, enter the number and, if applicable, any notes for our staff


Thank you.
Sharon Beasley, Building Permit Specialist

City of Tucson, Planning and Development Services
Email: COTDSDpermits@TucsonAz.gov
(disregard the email response that will be sent automatically)
12/14/2021 SBEASLE1 PIMA COUNTY ADDRESSING Reqs Change (The ATTACHED PDF mentioned below can be viewed in the "Documents" section of PRO: "Pima Co Addressing, review comments, second submittal")

Email from: <Addressing@pima.gov>
To: CDRC
Tue 12/14/2021 10:19 AM

Final Plat, Blackhawk, 2nd submittal, S21-056, is being Returned for Corrections by Pima County Addressing.
The attached pdf contains Addressing’s comments.
Please let me know if you have any questions.
Thank you,

Robin Freiman, Addressing Official

Pima County Development Services Department
201 N Stone AV – 1st Floor
Tucson, AZ 85701, (520) 724-7570