Review Date Reviewer's Name Type of Review Description Status Comments
08/12/2021 SBEASLE1 START PLANS BEING WALKED THRU Completed
08/16/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed
08/16/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. The parcel being divided is currently served by a single 5/8-inch water meter; a second water meter will be required once the parcel is split. Parcels that want a meter must have at least 15-feet of frontage on a water main. This land must be part of the property, not an easement.
2. The two manufactured homes share a common building sewer and HCS. To maintain this arrangement, a recorded joint sewer agreement will be required.
08/17/2021 STEVE SHIELDS ZONING REVIEW Denied PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: 821 W Thurber Rd.
S21-055
Land Split (1st Review)

TRANSMITTAL DATE: August 17, 2021

SECTION 2-08.0.0: LAND SPLIT

2-08.2.0 CONTENT REQUIREMENTS
1. COMMENT: 2-08.2.0 – The proposed land split exceeds the number of allowed splits for a parcel that was created via a final plat. Per UDC Article 11.4.20 definition of a Subdivision, C. Any property whose boundaries are fixed by a recorded plat, which is divided into more than two parts. To divide this parcel into two will require a minor subdivision.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov
08/23/2021 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Reqs Change Email from: Jeremiah.Jenkins@TucsonAz.gov
To: CDRC
Mon 8/23/2021 7:27 AM

Tucson Water does not approve of the split. Lot 2 will have no property frontage to a water main. 15' of real property frontage to a water main is required. Or a 15' Public Utility Easement will need to be granted across Lot 1 for a public water main to be brought to Lot 2 so service can be established.

Thank you,
Jeremiah Jenkins, Water Services Supervisor

City of Tucson Water Department, New Services
201 N Stone Ave, First Floor
Public Counter hours: Mon-Thur 8am to 4pm
Department Hours: Mon-Fri 8am to 4pm
Office: 520-791-5164
09/08/2021 LOREN MAKUS ENGINEERING REVIEW Denied See zoning comments.
09/08/2021 SBEASLE1 ZONING-RECORDATION REVIEW Reqs Change Email from: COTDSDPermits
To: James P.
Wed 9/8/2021 3:19 PM

LAND SPLIT PLAN
Returned for Corrections: S21-055

Description: Land Split - Divide one lot into two lots. 821 W THURBER RD

FEES DUE: $99.00
ONLINE PAYMENTS
https://www.tucsonaz.gov/pdsd/fees
If amount doesn't match "Fees Due", check back in a few hours after it is updated.

1- Click on: Pay Planning & Permit Fees
2- Enter your Permit Nbr, example: dp20-0000
(not case-sensitive but a hyphen-dash- is needed)
3- Business/Individual Name: Leave blank
4- Click "Continue"
5-Under the Pay column, check the boxes you want to pay
6- Click "Continue", then enter your credit card info

View comments and documents on PRO:
www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab and you will see different sections
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

YOUR NEXT STEPS
Submit the following items to the FILEDROP
1) Comment Response Letter (your response to the reviewer's Requires Change comments)
2) Survey or Exhibit (even if no changes were made)
3) Legal Descriptions
4) Any other items requested by reviewers

FILEDROP
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
Select "Existing Application", then in the "Permit Number" field, enter your number and any notes you want directed to the staff

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson, Planning & Development Services Dept.
Email for Land, Splits, Development Pkgs: COTDSDpermits@TucsonAz.gov
(disregard the email response that will be sent automatically)