Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Plan Number: S21-049
Parcel: Unknown

Review Status: Completed

Review Details: LOT SPLIT REVIEW

Plan Number - S21-049
Review Name: LOT SPLIT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/30/2021 SBEASLE1 START PLANS BEING WALKED THRU Completed
08/02/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Show how lot 19B will have access to water supply and a sewer connection.
08/03/2021 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
09/07/2021 LOREN MAKUS ENGINEERING REVIEW Approved
09/08/2021 SBEASLE1 ZONING-RECORDATION REVIEW Reqs Change Email from: COTDSDPermits
To: lisa bowers
Wed 9/8/2021 10:44 AM

LAND SPLIT PLAN
Returned for Corrections: S21-049

Description: LAND SPLIT - The Landing, Lot 19. 4764 S LANDING WY

Fee Balance: $0 (zero) Thank you for the payment.

View comments and documents on PRO:
www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab and you will see different sections
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

YOUR NEXT STEPS
Submit the following items to the FILEDROP
1) Comment Response Letter (your response to the reviewer's Requires Change comments)
2) Survey or Exhibit (even if no changes were made)
3) Legal Descriptions
4) Any other items requested by reviewers

FILEDROP
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
Select "Existing Application", then in the "Permit Number" field, enter your number and any notes you want directed to the staff

Thank you.

Sharon Beasley, Permit Specialist

City of Tucson, Planning & Development Services Dept.
Email for Land, Splits, Development Pkgs: COTDSDpermits@TucsonAz.gov
(disregard the email response that will be sent automatically)
09/20/2021 STEVE SHIELDS ZONING REVIEW Approved OK to record. Once the legal description have been recorded at the Pima County Accessor's Office submit the recorded deeds and legals to PDSD
09/20/2021 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Reqs Change Email from: Jeremiah.Jenkins@TucsonAz.gov
To: CDRC
Sat 8/14/2021 10:55 AM

Tucson Water does not approve of the split.
Lot 19B will have no property frontage to a water main.

Thank you,
Jeremiah Jenkins, Water Services Supervisor
City of Tucson Water Department, New Services
201 N Stone Ave, First Floor
Public Counter hours: Mon-Thur 8am to 4pm
Department Hours: Mon-Fri 8am to 4pm
Office: 520-791-5164