Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Plan Number: S21-047
Parcel: Unknown

Address:
830 E 7TH ST

Review Status: Completed

Review Details: LOT SPLIT REVIEW

Plan Number - S21-047
Review Name: LOT SPLIT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/22/2021 SBEASLE1 START PLANS BEING WALKED THRU Completed
07/22/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed
07/26/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. For the purposes of having a water meter, a parcel is required to have a minimum width of 15-feet of frontage on a water main. An easement is not considered to be frontage. Reference: Tucson Water Remote Meter Policy, Number IV-B.08, dated 07/14/2009.
2. Show the location of the existing HCS for parcel A and the location of the proposed HCS for parcel B. Each occupiable building shall have an independent connection to the public sewer. Reference: Section 701.3, IPC 2018.
07/30/2021 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Reqs Change Email from: Jeremiah.Jenkins@TucsonAz.gov
To: CDRC
Fri 7/30/2021 9:06 AM

Tucson Water does not approve of the lot split.
A minimum of 15' of property frontage to a water main is required for service.

Thank you,

Jeremiah Jenkins, Water Services Supervisor
City of Tucson Water Department,
New Services
201 N Stone Ave, First Floor
Public Counter hours: Mon-Thur 8am to 4pm
Department Hours: Mon-Fri 8am to 4pm
Office: 520-791-5164
07/30/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: 832 E 7th St
S21-047
Land Split (1st Review)

TRANSMITTAL DATE: July 30, 2021

SECTION 2-08.0.0: LAND SPLIT

2-08.2.0 CONTENT REQUIREMENTS
1. COMMENT: 2-08.5.F – Provide the heights of the exterior walls for the south and west elevations of the existing building so that perimeter yard setbacks requirements can be verified. Perimeter yard setbacks are based on a measurement from design grade to the highest point of the wall, see Unified Development Code (UDC) Article 6.4.5.b & Figure 6.4.5-A.

2. COMMENT: 2-08.5.G Provide a lot coverage calculation the meets the requirements of UDC Article 6.4.3 and the example provided on the requirements for residential plot plans found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov
08/27/2021 LOREN MAKUS ENGINEERING REVIEW Approved
08/30/2021 SBEASLE1 ZONING-RECORDATION REVIEW Reqs Change Email from: COTDSDPermits
To: David Stewart
Mon 8/30/2021 2:59 PM

LAND SPLIT PLAN
Returned for Corrections Notice

Permit/Activity: S21-047
Description: Land Split - 832 E. 7th Street. Split one lot into two lots.

Fee Balance: $0 (zero) Thank you for the payment.

View comments and documents on PRO:
www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab and you will see different sections
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

YOUR NEXT STEPS
Submit the following items to the FILEDROP
1) Comment Response Letter (your response to the reviewer's Requires Change comments)
2) Plan/Exhibit (even if no changes were made)
3) Legal Descriptions
4) Any other items requested by reviewers

FILEDROP
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
Select "Existing Application", then enter your Permit number

Thank you.

Sharon Beasley, Permit Specialist

City of Tucson, Planning & Development Services Dept.
Email for Land, Splits, Development Pkgs: COTDSDpermits@TucsonAz.gov
(disregard the email response that will be sent automatically)
Email for Building Permits: PDSDinquiries@TucsonAz.gov