Plan Review Detail
Review Status: Completed
Review Details: LOT SPLIT REVIEW
Plan Number - S20-078
Review Name: LOT SPLIT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/05/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PROVIDE A SIRE PLAN SHOWING THE DISTANCE FROM PROPOSED PROPERTY LINES TO EXISTING BUILDINGS. WHEN LESS THAN 3' A BUILDING PERMIT IS REQUIRED FOR ADDING ONE-HOUR FIRE RATING MATERIALS. |
| 01/07/2021 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. How will Parcel 2 obtain access to water service? Reference: Section 107.2.1, IBC 2018. 2. How will Parcel 2 have access to the public sewer system? Occupiable building located on separate properties shall have an independent connection to the public sewer. Reference: Section 701.3, IPC 2018. |
| 01/14/2021 | DAVID RIVERA | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL Nicholas Martell, Planner S20-078 Land Split January 14, 2021 The Land Split has been reviewed by the Zoning Review Section but cannot be approved until all zoning comments or concerns have been addressed. 1. Please submit a site plan in conformance with the standards in section 2-08.4.0 of the City of Tucson Administrative Manual. Below are the format and content requirements. 2-08.4.0 FORMAT REQUIREMENTS 4.1 The drawing showing the proposed land split shall be: A. Eleven inches by 17 inches or larger; B. Drawn to scale no less than one inch equals 20 feet; and C. Fully dimensioned. 4.2 A survey drawing and legal descriptions prepared by a registered surveyor may be required at the PDSD Director’s discretion. 2-08.5.0 CONTENT REQUIREMENTS The drawing showing the proposed land split shall include the following: A. The boundaries of the original parcel or lot prior to the land split with distance and bearings labeled; B. The proposed lots with distance and bearings labeled; C. The rights-of-way adjacent to or within the property, including streets and easements. The streets and easements must be labeled, dimensioned and purpose listed; D. All proposed easements on and surrounding the property; E. The locations and dimensions of any existing structures and buildings; F. The setbacks of existing buildings and structures from existing and proposed property lines; G. The land area of each proposed lot in square feet or acreage. If the property is developed, additional information, such as but not limited to FAR, lot coverage, vehicle and bicycle parking, may be needed; H. Access to all proposed lots in compliance with Section 7.8, Access; and, I. Whether there is any shared use of vehicle use areas, easements, etc. between properties. For reference, below is a web address for the submittal requirements for a land split: https://www.tucsonaz.gov/files/pdsd/forms/Submittal_Requirements.pdf If you have any questions about this transmittal, please contact me at Nicholas.Martell@tucsonaz.gov |
| 01/20/2021 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 01/21/2021 | SBEASLE1 | ZONING-RECORDATION | REVIEW | Reqs Change | DATE: January 21, 2021 LAND SPLIT PLAN RETURNED FOR CORRECTIONS NOTICE IMPORTANT - NEW FILEDROP: https://docs.tucsonaz.gov/Forms/tucsonpermitapp Select "Existing Application" PERMIT: S20-078 DESCRIPTION: LAND SPLIT - 1436 W. Fort Lowell Road. Split one parcel into two parcels FEES DUE: $0 (zero) Thank you for the payment. SEE REVIEW COMMENTS and your documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews - click on Review Details - Documents - click on View to the right of each document YOUR NEXT STEPS: Submit the following items to the NEW FILEDROP 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan/Drawing (even if no changes were made) 3) Any other items requested by reviewers Thank you. City of Tucson Attn: Sharon Beasley, Permit Specialist Planning and Development Services email: COTDSDPermits@TucsonAz.gov |
| 12/22/2020 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 12/28/2020 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Passed | 12/28/20 To Applicant: The address is located in the Flowing Wells Irrigation District. You may contact them at 520-887-4192 for details regarding water. Thank you, Jeremiah Jenkins Interim Supervisor/Engineering Associate City of Tucson Water Department, New Services, Hours: Mon-Fri 8am to 4pm Office: 520-791-5164, Direct: 520-837-2208 |