Review Status: Completed

Review Details: FINAL PLAT - REVIEW

Plan Number - S20-067
Review Name: FINAL PLAT - REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/14/2021 ELISA HAMBLIN ZONING REVIEW Reqs Change CDRC Transmittal
TO: Planning and Development Services Department
Plans Coordination Office

FROM: Elisa Hamblin, AICP; Principal Planner; PDSD Zoning Review Section

PROJECT: 1620 E Hedrick, Lots 1-3
Minor Subdivision (1st Review) - S20-067

TRANSMITTAL DATE: January 13, 2021

COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-07 and for compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

1. 2-07.4.3. – Have a two-inch margin on the left side and one-half inch margins on the remaining sides to comply with standardization requirements of state law for recorded plats;
2. 2-07.5.1.D. – Place the words “SEQ#________” (not “SEQUENCE NO.”) in both the upper and lower right corners outside the margin line. The blanks will be completed by the Pima County Recorder’s Office at the time of recordation.
3. 2-07.5.1.H. – The S20-067 subdivision case number assigned to the approved tentative plat must be placed in the lower right corner of the plat next to the title block.
4. 2-07.5.2. General Notes. The plat must include the following general notes. Additional notes specific to each project are required when pertinent. Fill in the blanks with the project-specific information.
5. 2-07.5.2.J. – If applicable, add the following note: “This subdivision is subject to Ordinance No. 1895 which established zoning in the North To Roger Rd. And East To Kolb Rd. Annexation Area.”
6. 2-07.5.3.B.2. – Dedication Language. Use one of the following four statements as may be appropriate for the plat. Section 2-07.5.3.B.2.c may be used in subdivisions with private elements. Section 2-07.5.3.B.2.d may be used where electrical facilities are not specifically located in common areas.
7. 2-07.5.3.B.2.a. – “(I/We) hereby dedicate and convey to the public forever all rights-of-way as shown hereon, including all streets, roads, parks, easements, and drainageways.”
8. 2-07.5.3.B.2.b. – “(I/We) hereby grant to the public and all utility companies all easements as shown hereon for the purposes of access for installation and maintenance of public sewers and utilities and other uses as designated by this plat.”
9. 2-07.5.3.B.2.c. – “Private streets, drainageways, and common areas, as shown hereon, are reserved for the private use and convenience of all owners of property within this subdivision and are granted as easements to the public and all utility companies for the purposes of access, installation, and maintenance of utilities, drainage, and public sewers. Title to the land of all private streets, drainageways, and common areas shall be vested in an association of individual lot owners as established by Covenants, Conditions, and Restrictions recorded in Sequence #________ in the Pima County Recorder’s Office. The association will accept responsibility for control, maintenance, and liability for the private streets, drainageways, private sewers, and common areas within this subdivision.”
10. 2-07.5.3.B.2.d. – “Private streets, drainageways, and common areas shown on this plat are reserved for the private use and convenience of all owners of property within this subdivision, and easements are granted to the public and all utility companies together with access for the installation, maintenance, and improvements of aboveground and underground utilities, public sewers, and drainage. Title to the land of all private streets, drainageways, and common areas will be vested in an association of individual lot owners as established by Covenants, Conditions, and Restrictions recorded in Sequence #________ in the Pima County Recorder’s Office. The association will accept responsibility for control, maintenance, and liability for the private streets, drainageways, private sewers, and common areas within this subdivision.”
11. 2-07.5.3.B.4. – Add the signature lines for the property owners. The number of signatures depends on the number of persons who have fee title interest according to a title report current within 30 days of recordation of the proposed plat.
12. 2-07.5.3.C. – If applicable, the following BENEFICIARY block must be included on the title page.
BENEFICIARY
“The beneficiary of (Title Company Name and Trust Number) is (Name and Address).”
13. 2-07.5.3.D. – Approval Data Block, Correct County Recorder name to Gabriella Cázares-Kelly. Insert the word “BY” on the signature line under the County Recorder name.

If you have any questions about this transmittal, please contact me at Elisa.Hamblin@tucsonaz.gov.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat.
01/26/2021 SBLOOD1 ENGINEERING REVIEW Reqs Change The Tentative Plat needs to be approved before the final plat can be approved.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
01/27/2021 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change DATE: January 27, 2021
Returned for Corrections / Request for Resubmittal

PERMIT/ACTIVITY: S20-067
DESCRIPTION: FINAL PLAT - 1620 E. Hedrick Drive, Lots 1-3.

FEES DUE: $ 1,116.50
Please pay the total fees (or at a minimum, the REVIEW Fees). A payment is required before your resubmittal.

ONLINE PAYMENT
https://www.tucsonaz.gov/pdsd/fees

PLEASE READ: If information is not available or amount isn't correct, check back in a few hours after data is updated.

(Visa, MC, Discover, American Express, or pay from bank account)
1- Click on: Pay Planning & Permit Fees
2- Enter your Permit Nbr, example: dp20-0000
(not case-sensitive but a hyphen-dash- is needed)
3- Business/Individual Name: Leave blank
4- Click the blue tab: Continue
5- Under the Pay column, check the boxes you want to pay
6- Click Continue, then enter your credit card info
7- If any issues, try using the browser Internet Explorer

RESUBMITTAL OF UPDATED/CORRECTED DOCUMENTS
Submit documents to NEW FILEDROP:
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
Select "Existing Application", then the permit number

1) Comment Response Letter
(your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

- Title the documents for your 2nd submittal starting with the
submittal number, for example: 2_Plan_Set

SEE REVIEW COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews - click on Review Details
- Documents - click on View to the right of each document

FYI - For all NEW development package submittals in the future (not resubmittals) on the Filedrop page, select the box: "SITE REVIEW...".

Thank you.

City of Tucson
Attn: Sharon Beasley, Permit Specialist
Planning and Development Services
email: COTDSDPermits@TucsonAz.gov
11/20/2020 SBEASLE1 START PLANS SUBMITTED Completed
11/20/2020 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Reqs Change To Applicant: Please contact Tucson Water (or Ray Water Company, if applicable). Request a Water Availability letter. Submit it to the City of Tucson with your next submittal. Mayor and Council cannot grant approval until water is assured.
11/24/2020 SBEASLE1 UTILITIES SOUTHWEST GAS Passed
11/24/2020 SBEASLE1 PIMA COUNTY WASTEWATER Approved Wastewater
Email for 1620 E. Hedrick, Lots 1-2

Hi Jeff,
we do not need to review the attached Final Plat because they do not involve pubic sewer.
Thanks.

Respectfully,
Thomas W.Porter, P.E., Civil Engineer
DSD-Site Group
201 N. Stone Ave., 1st Floor, Tucson, AZ 85701-1207
ph: (520) 724-6719
11/24/2020 ED ABRIGO PIMA COUNTY ASSESSOR Reqs Change FROM: Suzanne Gilpin, GIS Cartographer, Pima County Assessor's Office,(520)724-4387

DATE: November 23, 2020

RE: Assessor's Review and Comments Regarding Final Plat- S20-067 - 1620 E. HEDRICK

__X___ Plat does not meet Assessor's Office requirements.

COMMENTS:

1. There must be bearings and dimensions for the perimeter and all lot lines and all common areas.

***(PLEASE NOTE THAT THE APPLICATION HAS THE INCORRECT TAX PARCEL NUMBER: IT SHOULD READ 113-07-1050)***
12/18/2020 SBEASLE1 PIMA COUNTY ADDRESSING Reqs Change (The ATTACHED PDF mentioned below can be viewed online: www.TucsonAz.gov/Pro. See the Documents section.)

12/18/20
S20-067, 1620 E. Hedrick, Final Plat, 1st submittal is being Returned for Corrections by Pima County Addressing.
The attached pdf contains Addressing’s comments.
Please let me know if you have any questions.

Thank you,
Robin Freiman, Addressing Official

Pima County Development Services Department
201 N Stone AV – 1st Floor
Tucson, AZ 85701
(520) 724-7570
12/21/2020 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved 12/21/20

Tucson Electric Power Co., (TEP) has reviewed and approves the final plat for the above referenced project. TEP easements may be required for future development and will be obtained by separate instrument.
If there are any questions, please contact me at 520-401-9895.

Thank you,
Mary Burke, Senior Right of Way Agent

Tucson Electric Power Co.
Land Resources – RC 131
3950 E. Irvington Road
Tucson, AZ 85714-2114
Cell - 520-401-9895
mburke@tep.com