Plan Review Detail
Review Status: Completed
Review Details: LOT SPLIT REVIEW
Plan Number - S20-063
Review Name: LOT SPLIT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/26/2020 | SBEASLE1 | START | PLANS BEING WALKED THRU | Completed | |
| 10/27/2020 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Approved | Tucson Water approves lot split. Jeremiah Jenkins Interim Supervisor/Engineering Associate, City of Tucson Water Department, New Services Office: 520-791-5164 Direct: 520-837-2208 |
| 10/28/2020 | STEVE SHIELDS | ZONING | REVIEW | Denied | PDSD TRANSMITTAL FROM: Steve Shields Section Manager PROJECT: 1898 S Mission Rd S20-063 Land Split TRANSMITTAL DATE: October 28, 2020 The land split has been reviewed by the Zoning Review Section for minimal compliance with the Administrative Manual Section 2-08 & Unified Development Code Article 8.3.1. It has been determined that by definition the proposed land split constitutes a subdivision therefore cannot be processed as a land split. As this parcel has floor plain Zone AH a tentative plan final plat will be required to divide this parcel. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 |
| 11/02/2020 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 11/04/2020 | LOREN MAKUS | ENGINEERING | REVIEW | Reqs Change | 1. As indicated in the Email from Alexandra Hines, this land division must be by a subdivision process. 2. The UDC doesn't allow the use of the minor subdivision process when the property is within a floodplain (UDC 8.4.3.B.6 The City Attorney has instructed us to apply this if any part of the affected parcel is within the floodplain. 3. The UDC doesn't allow the use of the minor subdivision process if the site has requirements or affected by a WASH ordinance watercourse (UDC 8.4.3.B.8.) 4. The boundaries of the FEMA flood hazard areas are adopted by reference by the Tucson Floodplain Regulations Sec. 26-1.3 and the boundaries on the FIRM apply until revised by a Letter of Map Change. |
| 11/17/2020 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 11/18/2020 | SBEASLE1 | ZONING-RECORDATION | REVIEW | Reqs Change | DATE: November 18, 2020 LAND SPLIT PLAN RETURNED FOR CORRECTIONS NOTICE Your next steps: Resubmittal of documents PERMIT: S20-063 DESCRIPTION: Land Split - One parcel into two parcels. 1898 S. Mission Road. FEES DUE: $0 (zero) Thank you for the payment. SEE REVIEW COMMENTS and your documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews - click on Review Details - Documents - click on View to the right of each document YOUR NEXT STEPS: Submit the following items to the Filedrop https://www.tucsonaz.gov/pdsd-filedrop 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan/Drawing (even if no changes were made) 3) Any other items requested by reviewers IMPORTANT: On the Filedrop page, select the Submission Type: Site Review/CDRC... Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services email: COTDSDPermits@TucsonAz.gov |