Plan Review Detail
Review Status: Completed
Review Details: LOT SPLIT REVIEW
Plan Number - S20-055
Review Name: LOT SPLIT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/08/2020 | SBEASLE1 | START | PLANS BEING WALKED THRU | Completed | |
| 09/09/2020 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 09/14/2020 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Approved | Tucson Water approves this lot split. Thank you, Ray Munoz Ray.Munoz@TucsonAz.gov |
| 09/16/2020 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: Steve Shields Section Manager PROJECT: 2833 E 5th St. - R-1 Zone S20-055 Land Split/Lot Line Reconfiguration (1st Review) TRANSMITTAL DATE: September 16, 2020 This site is located in the R-1 zone (UDC 4.7.8). SECTION 2-08.0.0: LAND SPLIT 2-08.4.0 FORMAT REQUIREMENTS 2-08.4.1 The drawing showing the proposed land split shall be: 2-08.4.1.C - Clearly show the proposed lot line on the plan along with distance and bearings for the proposed lot line. Until these are provided the legal descriptions cannot be verified. 2-08.5.0 CONTENT REQUIREMENTS The drawing showing the proposed land split shall include the following: 2-08.5.B - Clearly show the proposed lots with distance and bearings labeled, see comment 1 above. 2-08.5.F - Depending on where the proposed property line is placed it appears that the existing garage located northwest of the eastern most residence will not meet perimeter yard setbacks. A neighbor sign off for setback waiver maybe required. The following statement needs to be provided on the plan: "My Name is and I am the owner of the property located at . I have reviewed the site plan and I have no objection to structure being located or constructed from the property line as depicted on the site plan. This signoff can be done by the current owner for his own property. 2-08.5.G - Provide the land area of each proposed lot in square feet or acreage. 2-08.5.G - Provide a lot coverage calculation for both proposed lots. |
| 09/23/2020 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Completed | |
| 09/29/2020 | SBLOOD1 | ENGINEERING | REVIEW | Reqs Change | 1. Show distinguishing line weights for existing and proposed lot lines. 2. Show all proposed lot lines with bearings and distances as per Section 2-08.5.B in the Administative Manual Stephen Blood stephen.blood@tucsonaz.gov |
| 09/29/2020 | SBEASLE1 | ZONING-RECORDATION | REVIEW | Reqs Change | DATE: Sept. 29, 2020 LAND SPLIT PLAN RETURNED FOR CORRECTIONS NOTICE Your Next Steps: Resubmittal of your updated/corrected documents DESCRIPTION: LAND SPLIT - 2833 E. 5th Street. PERMIT/ACTIVITY: S20-055 FEE BALANCE: $0 (zero) Thank you for the payment. SEE REVIEW COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews - click on Review Details - Documents - click on View to the right of each document YOUR NEXT STEP: Submit documents to the Filedrop https://www.tucsonaz.gov/file-upload-pdsd 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff - Name the 2nd submittal documents starting with the submittal number, for example: 2_Plan_Set IMPORTANT: On the Filedrop page, select the box: "Site Review/CDRC..." Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services email: COTDSDPermits@TucsonAz.gov |