Plan Number: S20-054
Parcel: Unknown

Address:
1014 E LINDEN ST

Review Status: Completed

Review Details: LOT SPLIT REVIEW

Plan Number - S20-054
Review Name: LOT SPLIT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/04/2020 SBEASLE1 START PLANS BEING WALKED THRU Completed
09/09/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
09/14/2020 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved Tucson Water approves this lot split.

Thank you,

Ray Munoz
Ray.Munoz@TucsonAz.gov
09/14/2020 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Steve Shields
Section Manager

PROJECT: 1014 E Linden & 1832 N. Park - NR-1 Zone
S20-054
Land Split/Lot Line Reconfiguration (1st Review)

TRANSMITTAL DATE: September 14, 2020

This site is located in the NR-1 zone (UDC 4.7.8).


1. Per UDC 6.3-2.A: DIMENSIONAL STANDARDS FOR THE R-1, R-2, R-3, MH-1, & MH-2 ZONES, R-1 zone, the minimum lot size is 7,000 sq. ft. Parcels 1 & 2 do not meet this requirement.

2. Provide a lot coverage calculation for parcels 2 & 3.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
09/21/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed
09/28/2020 SBLOOD1 ENGINEERING REVIEW Reqs Change 1. Need to show existing utility service connection locations and any existing utility easements

2. Need to show survey drawing showing only the lots existing and proposed with scaled dimensions as per Administrative Manual section 2-08.5

3. Access to all proposed lots in compliance with Section 7.8, Access

4. Whether there is any shared use of vehicle use areas, easements, etc. between properties

Stephen Blood
Stephen.blood@tucsonaz.gov
09/28/2020 SBEASLE1 ZONING-RECORDATION REVIEW Reqs Change DATE: Sept. 28, 2020

LAND SPLIT PLAN
RETURNED FOR CORRECTIONS NOTICE
Your next steps: Resubmittal of documents

PERMIT: S20-054
DESCRIPTION: LOT SPLIT/RECON - Studwell Parcel Reconfiguration, 1014 E LINDEN ST

FEES DUE: $0 (zero) Thank you for the payment.

SEE REVIEW COMMENTS and your documents on PRO:
www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews - click on Review Details
- Documents - click on View to the right of each document

YOUR NEXT STEPS:
Submit the following items to the Filedrop
https://www.tucsonaz.gov/file-upload-pdsd
1) Comment Response Letter (your response to the reviewer's Requires Change comments)
2) Plan/Drawing (even if no changes were made)
3) Any other items requested by reviewers

IMPORTANT:
On the Filedrop page, select the box: Site Review/CDRC...

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
email: COTDSDPermits@TucsonAz.gov