Review Details: LOT SPLIT REVIEW
Plan Number - S20-054
Review Name: LOT SPLIT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/04/2020 | SBEASLE1 | START | PLANS BEING WALKED THRU | Completed | |
| 09/09/2020 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 09/14/2020 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Approved | Tucson Water approves this lot split. Thank you, Ray Munoz Ray.Munoz@TucsonAz.gov |
| 09/14/2020 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: Steve Shields Section Manager PROJECT: 1014 E Linden & 1832 N. Park - NR-1 Zone S20-054 Land Split/Lot Line Reconfiguration (1st Review) TRANSMITTAL DATE: September 14, 2020 This site is located in the NR-1 zone (UDC 4.7.8). 1. Per UDC 6.3-2.A: DIMENSIONAL STANDARDS FOR THE R-1, R-2, R-3, MH-1, & MH-2 ZONES, R-1 zone, the minimum lot size is 7,000 sq. ft. Parcels 1 & 2 do not meet this requirement. 2. Provide a lot coverage calculation for parcels 2 & 3. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 |
| 09/21/2020 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Completed | |
| 09/28/2020 | SBLOOD1 | ENGINEERING | REVIEW | Reqs Change | 1. Need to show existing utility service connection locations and any existing utility easements 2. Need to show survey drawing showing only the lots existing and proposed with scaled dimensions as per Administrative Manual section 2-08.5 3. Access to all proposed lots in compliance with Section 7.8, Access 4. Whether there is any shared use of vehicle use areas, easements, etc. between properties Stephen Blood Stephen.blood@tucsonaz.gov |
| 09/28/2020 | SBEASLE1 | ZONING-RECORDATION | REVIEW | Reqs Change | DATE: Sept. 28, 2020 LAND SPLIT PLAN RETURNED FOR CORRECTIONS NOTICE Your next steps: Resubmittal of documents PERMIT: S20-054 DESCRIPTION: LOT SPLIT/RECON - Studwell Parcel Reconfiguration, 1014 E LINDEN ST FEES DUE: $0 (zero) Thank you for the payment. SEE REVIEW COMMENTS and your documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews - click on Review Details - Documents - click on View to the right of each document YOUR NEXT STEPS: Submit the following items to the Filedrop https://www.tucsonaz.gov/file-upload-pdsd 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan/Drawing (even if no changes were made) 3) Any other items requested by reviewers IMPORTANT: On the Filedrop page, select the box: Site Review/CDRC... Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services email: COTDSDPermits@TucsonAz.gov |