Plan Review Detail
Review Status: Completed
Review Details: SUBPLAT- OK TO SUBMIT
Plan Number - S20-053
Review Name: SUBPLAT- OK TO SUBMIT
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
09/01/2020 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
09/02/2020 | LOREN MAKUS | ENGINEERING | REVIEW | Denied | 1. A presubmittal is required before application for a minor subdivision. 2. Site is not eligible for a minor subdivision. The property is within a city flood hazard area. A tentative plat will be required. 3. Confirm with Tucson Water that the configuration will allow service to both lots. 4. Existing structures were constructed without permits. Accessory structures are not permitted without a main structure. 5. Show existing access for existing homes. Entry drive must be improved to street or PAAL standards if it serves 3 or more units. Loren Makus email: Loren.Makus@TucsonAz.gov |
09/03/2020 | STEVE SHIELDS | ZONING | REVIEW | Denied | See Engineering comments |
09/03/2020 | SBEASLE1 | ZONING-DECISION LETTER | WRITE DECISION LETTER | Reqs Change | PLAN DENIED FOR REVIEW NOTICE / Changes are required NOTE: Please follow the steps below to resubmit your documents for review. Permit/Activity Number: S20-053 (Enter this number in your next submittal) Project Description: MINOR SUBDIVISION - Denny Glenn Street. Split into 2 lots. To view the "Subplat - Okay to Submit" comments by Reviewers on PRO: 1. www.tucsonaz.gov/pro 2. Home page, left side - Activity Search 3. Enter the Activity Number (it’s not case-sensitive) 4. Under "Permits" heading, click on blue tab (Permit/Activity Number) 5. In "Reviews" section, click on (blue) Review Details (If complete information isn't shown yet, check back later after data transfers to PRO.) After corrections are made, name your documents again as a first submittal (the number one leads the title), for example: 1_Application. Upload all documents to the City of Tucson's Filedrop page and enter permit # S20-053 (On the Filedrop page, select the Submission Type "Site Review/CDRC...") Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services email: COTDSDPermits@TucsonAz.gov |
09/03/2020 | SBEASLE1 | ZONING-DECISION LETTER | WRITE DECISION LETTER | Reqs Change | February 5, 2021 The approved permit# DP20-0185 is related to the final plat S20-053 for the same address/project. We are ready for your resubmittal of S20-053. It had been denied until this Tentative Plat DP20-0185 was approved. See DP20-0185 approval in email below. After following the engineering review comment instructions for S20-053 in PRO (link below), upload your 1st submittal final plat documents to the filedrop, link below. SEE REVIEW COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro - Home page, Activity Search, enter the Activity/Permit Number S20-053 - Permits - click on blue tab - Reviews - click on Review Details FILEDROP for all new permit applications and all resubmittals https://docs.tucsonaz.gov/Forms/tucsonpermitapp Resubmittals: select "Existing Application", then enter the permit number S20-053 City of Tucson Attn: Sharon Beasley, Permit Technician Planning & Development Services Dept. Email: COTDSDPermits@Tucsonaz.gov |