Plan Number: S20-034
Parcel: Unknown

Review Status: Completed

Review Details: LOT SPLIT REVIEW

Plan Number - S20-034
Review Name: LOT SPLIT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/18/2020 SBEASLE1 START PLANS BEING WALKED THRU Completed
05/18/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
05/19/2020 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change S20-034

1) Aerial Imagery shows multiple structures along the southern property boundary. Provide a site plan which shows these buildings and their set backs from surrounding property lines to ensure that proper zoning requirments are being met. Also provide set backs for the "carport" and "shed" shown in lot B

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
05/20/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed
05/20/2020 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved Tucson Water approves this lot split.

Thank you,
Ray Munoz
05/21/2020 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Steve Shields
Section Manager

PROJECT: 5808 E Beverly St.
S20-034
Land Split (1st Review)

TRANSMITTAL DATE: May 21, 2020

1. Per Unified Development Code (UDC) Article 6.6.3.B Detached accessory buildings are not permitted in the buildable area extending the full width of the lot between the principal building and the front street lot line, except for terraces and steps not over three feet high above the natural grade, paved areas, and fences or walls. That said all structures located on LOTB will need to be removed from the site prior to approval of this land split. Also remove the structures from this plan or show them to be demolished.

2. Provide a lot coverage calculation for LOTA that meets the requirements of UDC Article 6.4.3.

3. Clarify what "Surveyer 4, square foot" sheet is for.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
05/22/2020 SBEASLE1 ZONING-RECORDATION REVIEW Reqs Change LAND SPLIT PLAN
RETURNED FOR CORRECTIONS NOTICE

HOLIDAY:
All City of Tucson departments (except for emergency services) will be closed on Monday, May 25, for Memorial Day.

PERMIT: S20-034
DESCRIPTION: LAND SPLIT - 5808 E. Beverly Street. Split one lot into two lots.

FEES DUE: $0 (zero) Thank you for the payment.

SEE REVIEW COMMENTS and your documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews - click on Review Details
- Documents - click on blue icon to the right of each document

YOUR NEXT STEPS: Submit the following items to the Filedrop
https://www.tucsonaz.gov/file-upload-pdsd

For quicker processing, on the Filedrop page, select the box "Development Package or Land Division". This applies to all DP submittals, DP resubmittals, and DP revisions - and all Land Splits.
(For Building Permits, continue to select "Resubmittals/Revisions...".)

1) Comment Response Letter (your response to the reviewer's Requires Change comments)
2) Site Plan (even if no changes were made)
3) Any other items requested by reviewers

CONTACT US Monday-Friday, 8:00 am to 12:00 noon - CLOSED UNTIL TUESDAY, MAY 26
https://www.tucsonaz.gov/pdsd/virtual-service-counter
For information or an over-the-counter review, sign in to the
Virtual Service Counter and we will give you a call.

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
email: COTDSDPermits@TucsonAz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
05/22/2020 SBEASLE1 OUT TO CUSTOMER Completed