Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Plan Review Detail
Review Status: Completed
Review Details: LOT SPLIT REVIEW
Plan Number - S20-030
Review Name: LOT SPLIT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/24/2020 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 04/27/2020 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | REMOVE THE PRELIMINARY NOTATION FROM THE SEAL AND SIGN ON THE APPROVAL SUBMISSION. |
| 04/27/2020 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 04/28/2020 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL PDSD TRANSMITTAL FROM: Steve Shields Section Manager PROJECT: Parcel 122-18-3840 Land Split (1st Review) - 3525 E Willard St S20-030 - R-2 Zoning TRANSMITTAL DATE: April 28, 2020 DUE DATE: April 29, 2020 COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) 8.3.1 Land Split and Administrative Manual (AM) Section 2-08. Also compliance with applicable development criteria for the proposed or existing use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). 1. Lot 2 legal description 7th "THENCE" the distance shown is 65.01 and on the map it shows 60.01, which is correct. 2. Remove all proposed development from the site plan as the proposed will be reviewed under a separate permit. 3. There is a "PORCH FOR 2 CARS" shown on lot #1, this structure has not been permitted and will require a Board of Adjustment for Variance as: a. Detached accessor structures are not allowed in the front yard, see UDC Article 6.6.3.B b. Front street perimeter yard setback is not met, see UDC Article 6.4.5.C.1.a c. Side yard perimeter yard setback is not met, see UDC TABLE 6.3-2.A: DIMENSIONAL STANDARDS FOR THE R-1, R-2, R-3, MH-1, & MH-2 ZONES, R-2 Zone, Res Use to Res. Zone This Variance must be approved prior to approval of the land split If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Corrected plans, requested or required documents as noted by zoning comments. |
| 04/29/2020 | LOREN MAKUS | ENGINEERING | REVIEW | Reqs Change | 1. Ensure the legal descriptions and the drawings are consistent. 2. Be aware the site is within a flood hazard area. All new construction and development will require floodplain review and approval. |
| 05/01/2020 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Approved | Tucson Water approves this lot split. Thank you, Ray Munoz Ray.Munoz@TucsonAz.gov Tucson Water |
| 05/01/2020 | SBEASLE1 | ZONING-RECORDATION | REVIEW | Reqs Change | LAND SPLIT PLAN RETURNED FOR CORRECTIONS NOTICE Note: Payment and a resubmittal with a Comment Response Letter is required. PERMIT: S20-030 DESCRIPTION: LAND SPLIT - 3525 E. Willard Street. FEES DUE: $99.00 Note: Prior to accepting a resubmittal, we require payment in full. Payment options: 1. Online Payment Online Payment https://www.tucsonaz.gov/pdsd/online-resources-fees-maps-records 1. NOTE: It may take 1-2 days for complete permit information to be available online 2. Visa, MC, Discover, American Express or pay by checking account 3. Not case-sensitive but a hyphen is needed, for example: dp19-2000 4. Enter your Permit Nbr 5. Business/Individual Name: Leave blank 6. Click the blue Continue tab 7. If any issues, try using the browser Internet Explorer SEE REVIEWER'S COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, left side, Activity Search, enter the Activity Number - Permits section, click on blue tab - Reviews section, click on Review Details - Documents section, click on blue icon to the right of each document YOUR NEXT STEPS: Submit the following items to the Filedrop - https://www.tucsonaz.gov/file-upload-pdsd 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Any other items requested by reviewers After your resubmittal, the Land Split Plan will enter a new 5day working-day review cycle. Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services email: COTDSDPermits@TucsonAz.gov CONTACT US Monday-Friday, 8:00 am to 12:00 noon https://www.tucsonaz.gov/pdsd/virtual-service-counter To request information or an over-the-counter review, sign in to the Virtual Service Counter and we will give you a call. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/01/2020 | SBEASLE1 | OUT TO CUSTOMER | Completed |