Plan Review Detail
Review Status: Completed
Review Details: FINAL PLAT - REVIEW
Plan Number - S20-019
Review Name: FINAL PLAT - REVIEW
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/08/2020 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
04/08/2020 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Reqs Change | To Applicant: Please provide a Water Availability Letter from Tucson Water (or Ray Water Company, if applicable) in the next submittal. Mayor & Council cannot approve until water is assured. |
04/08/2020 | SBEASLE1 | UTILITIES | SOUTHWEST GAS | Passed | Review not required. This agency was notified for their information only. |
04/08/2020 | SBEASLE1 | PIMA COUNTY | WASTEWATER | Reqs Change | To Applicant: Please provide an approval document in the next resubmittal. The Applicant is responsible for obtaining review and approval for wastewater from Pima County (email: Sewer@Pima.gov) prior to Mayor & Council approval of this final plat. |
04/24/2020 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approved | Lot square footage listed in table rather than on parcel which is acceptable. La Estancia De Tucson Phase 2 Parcel 1 S20-019 meets Assessor’s Office requirements. Joyce L Hays, Pima County Assessor’s Office Program Manager (Property Ownership and Mapping) 240 N. Stone Ave., Tucson AZ 85701 Phone: 520-724-8257 |
04/28/2020 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Reqs Change | Tucson Electric Power Co. (TEP) has reviewed the final plat submitted on April 8, 2020, and is unable to approve at this time. Easements for TEP facilities as identified on the Preliminary Construction drawing provided on April 27, 2020, must be shown on the final plat in order for us to approve. If there are any questions, please contact me at 520-401-9895 Mary Burke, Senior Right of Way Agent Tucson Electric Power Co. mburke@tep.com |
05/01/2020 | SBEASLE1 | PIMA COUNTY | ADDRESSING | Reqs Change | (The attached PDF mentioned below can be viewed online: www.TucsonAz.gov/Pro. See the Documents section.) La Estancia Phase 2, parcel 1, Lots 1-193 (final plat), S20-019 , 1st submittal is being Returned for Corrections by Pima County Addressing. The attached pdf contains Addressing’s comments. Please let me know if you have any questions. Thank you, Robin Freiman, Addressing Official Pima County Development Services Department (520) 724-7570 |
05/01/2020 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Reqs Change | S20-019 1) Show on at the bottom right hand corner of each sheet the information noted in City of Tucson (COT) Administrative Manual Section (AM) 2-07.5.1.E 2) Please add the dedication language found in the COT AM Section 2-07.5.3.B.2.a 3) Please add the dedication language found in the COT AM Section 2-07.5.3.B.2.c 4) Reference COT AM section 2-07.5.4 F. Show the limits of the 100-year floodprone area in a surveyable and readily retraceable manner with frequent ties to intersecting lot lines for all flows of 100 cfs or more; E. Show required setbacks, such as erosion hazard, drainage, etc. 5) Per COT AM Section 2-07.5.4. G. Corner lots may be designated with a star symbol indicating which street will be used for access. Use of this designation may limit design options for access. In instances where the city, for safety reasons, limits accessibility, a one-foot no-access easement will be required; 6) Per COT AM Section 2-07.5.4. I. Show detention/retention areas in a surveyable and readily retraceable manner; 7) Per COT AM section 2-07.5.5.C.2.B; A one-half inch iron rod tagged by a registered land surveyor must be set at all corners upon completion of construction. Add a symbol to the legend on sheet 1 and show on plans this symbol at all property corners 8) Provide a copy of the proposed CC&R's upon next submittal 9) Please reference COT Technical Standards Manual (TSM) section 10-01.5.0 for dimensions and diagrams relating to Site Visibility Triangles 10) Please show the emergency access easement through lot 122 11) Approval of the Tentative Plat is required prior to approval of the final plat John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov |
05/02/2020 | ELISA HAMBLIN | ZONING | REVIEW | Reqs Change | CDRC Transmittal TO: Planning and Development Services Department Plans Coordination Office FROM: Elisa Hamblin, AICP Principal Planner PDSD Zoning Review Section PROJECT: La Estancia, Phase 2, parcel 1. Lots 1-193. 6890 E Camino Boleadoras Final Plat (1st Review), S20-019 TRANSMITTAL DATE: May 1, 2020 DUE DATE: May 4, 2020 COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-07. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). 1. General Comment: This final plat is related to the tentative plat DP19-0313. The final plat cannot be approved until the DP has been issued. Please ensure any remaining corrections on the DP do not change the final plat without adequately documenting on a future submittal. 2. 2-07.5.1.A.4. – On the project location map on sheet 1 include the subdivisions within the map area. 3. 2-07.5.1.F. – Relocate the north arrow on each sheet to the upper right corner with the scale of the drawing beneath the arrow. 4. 2-07.5.1.H. – The DP20-0313 subdivision case number assigned to the approved tentative plat must be placed in the lower right corner of the plat next to the title block. As the property is subject to a rezoning case, the C9-99-SP-7 rezoning case number is to be noted also. The assigned final plat number of S20-019 must be noted also. 5. 2-07.5.2.D. – As the property is subject to conditions of rezoning, correct General Note 8 to read: “This plat is subject to the conditions of rezoning case number C9-99-SP-7, unless superseded by a subsequent rezoning ordinance.” 6. 2-07.5.2.E. – If subject to floodplain requirements, add the following note: “Prior to issuance of any building permit, a Flood Plain Use Permit is required for Lots ____.” 7. 2-07.5.2.J. – If applicable, add the following note: “This subdivision is subject to Ordinance No. 8655 which established zoning in the Wilmot/I-10 Annexation Area.” 8. 2-07.5.3.B.1. – Amend the Certification of Title paragraph to add a comma after “undersigned”. 9. 2-07.5.3.B.2.b. – Correct paragraph 2 under the Dedication to read exactly: “We hereby grant to the public and all utility companies all easements as shown hereon for the purposes of access for installation and maintenance of public sewers and utilities and other uses as designated by this plat.” 10. 2-07.5.3.B.3. – Correct paragraph 4 under the Dedication to read exactly: “We, the undersigned, do hereby hold harmless the City of Tucson, its successors and assigns, their employees, officers, and agents from any and all claims for damages related to the use of the property depicted on this plat now and in the future by reason of flooding, flowage, erosion, or damage caused by water, whether surface flood or rainfall.” 11. 2-07.5.3.E. – Correct the Assurances block to remove the ‘s’ at the end of “performance”. 12. 2-07.5.4.A. – Indicate dedication notation for vehicle no access easement and public utility easement in various locations and on multiple sheets. 13. 2-07.5.4.A. – Clarify 10’ public utility easement at the north end of S Vuelta De Ocho Rios is in the correct location as it is currently indicated on the ROW instead of adjacent to the ROW (see sheet 8). 14. 2-07.5.4.B. – Identify each block or lot within the subdivision boundary by number, and include the square footage of each. Lots 53, 72 and 73 on Sheet 5 are missing the lot number. 15. 2-07.5.4.G – Corner lots may be designated with a star symbol indicating which street will be used for access. Use of this designation may limit design options for access. In instances where the city, for safety reasons, limits accessibility, a one-foot no-access easement will be required; 16. 2-07.5.6. – Provide Protective covenants or Covenants, Conditions, and Restrictions (CC&Rs) establishing responsibility for construction, maintenance, and ownership of any proposed common area, open space, private street, or similar joint use, when needed, with next submittal. These covenants or CC&Rs will: 17. 2-07.5.6.A. – Provide for maintenance of and liability for any proposed commonly-owned areas; and 18. 2-07.5.6.B. – Include the various conditions of rezoning or other special situations requiring permanent administration by an owners’ association. If you have any questions about this transmittal, please contact me at Elisa.Hamblin@tucsonaz.gov or (520) 837-4966. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat. |
05/04/2020 | SBEASLE1 | OTHER AGENCIES | TUCSON AIRPORT AUTHORITY | Approved | May 4, 2020 RE: S20-019 / FINAL PLAT - La Estancia, Phase 2, parcel 1, Lots 1-193, Common area A1, B1, C1, D1, E1, F1, G1, H1, I1, and J1 (drainage, retention), 1st submittal, Received April 8, 2020 Thank you for the opportunity to comment on S20-019, La Estancia, Phase 2, parcel 1, Lots 1-193; 1st Submittal, a development package application of a Final Plat for an approximately 42.95 acre site, located southwest of the intersection of South Kolb Road and East Camino Boleadoras. The property is zoned Planned Area Development 7 (PAD-7), with the proposed development being a single family residential development. This site is within the Tucson International Airport avigation easement requirements and public disclosure area, FAA traffic pattern airspace, and FAA Part 77 airspace. The Tucson Airport Authority is satisfied with the 1st submittal of this project and has no additional comments to provide. Please do not hesitate to contact me if you have any questions or concerns regarding this comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520-573-4811. Respectfully, Scott Robidoux, C.M., Senior Airport Planner Tucson Airport Authority |
05/04/2020 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | RETURNED FOR CORRECTIONS NOTICE Your Next Step: Resubmittal of documents DESCRIPTION: FINAL PLAT - La Estancia, Phase 2, parcel 1. Lots 1-193. Common area A1, B1, C1, D1, E1, F1, G1, H1, I1, and J1 (drainage, retention). PERMIT/ACTIVITY: S20-019 FEE BALANCE: $0 (zero) SEE REVIEWER'S COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, left side, Activity Search, enter the Activity Number - Permits section, click on blue tab - Reviews section, click on Review Details - Documents section, click on blue icon to the right of each document YOUR NEXT STEPS: Submit the following items to the Filedrop - https://www.tucsonaz.gov/file-upload-pdsd 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff - Name your 2nd submittal documents to start with the submittal number, for example: 2_Plan_Set NOTE: The City of Tucson's Permit Counter at 201 N. Stone Avenue (the physical office) is closed to the public until further notice. In the meantime, our staff is working remotely from home. All communications are by telephone or email. CONTACT US Monday-Friday, 8:00 am to 12:00 noon https://www.tucsonaz.gov/pdsd/virtual-service-counter To request information or an over-the-counter review, sign in to the Virtual Service Counter and we will give you a call. Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services email: COTDSDPermits@TucsonAz.gov |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
05/04/2020 | SBEASLE1 | OUT TO CUSTOMER | Completed |