Plan Number: S20-015
Parcel: Unknown

Review Status: Completed

Review Details: LOT SPLIT REVIEW

Plan Number - S20-015
Review Name: LOT SPLIT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/27/2020 SBEASLE1 START PLANS SUBMITTED Completed
03/04/2020 DJELLEN1 ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: David Jellen
PDSD Zoning Review Section

PROJECT: 5642 S. Alvernon
Land Split (1st Review)
S20-015

TRANSMITTAL DATE: March 4,, 2020

DUE DATE: March 5, 2020

COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) 8.3.1 Land Split and Administrative Manual (AM) Section 2-08. Also compliance with applicable development criteria for the proposed or existing use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

8.3.1. LAND SPLIT

2-08.5.0 CONTENT REQUIREMENTS
The drawing showing the proposed land split shall include the following:

A. The proposed lots with distance and bearings labeled;

COMMENT: Provide a legible survey together with the legal descriptions that has all distance and bearing information labeled legibly. Remove the property line so that Parcel A and B are shown as they will be as one parcel. Rename Parcel A and B so that they have one name.


COMMENT: Clarify that Parcel 140-05-033F is remaining as a separate parcel.


COMMENT: The provided legal descriptions inaccurately describe Parcel B as if it is being created as a new, unique Parcel rather than as a combined Parcel with Parcel A. The legal descriptions should describe the new boundaries of the two newly adjusted parcels.


B. The rights-of-way adjacent to or within the property, including streets and easements. The streets and easements must be labeled, dimensioned and purpose listed;

COMMENT: If applicable, provide all relevant easement information for the project location as noted by the standard above.


C. The locations and dimensions of any existing structures and buildings;

COMMENT: Provide a supplemental site plan for the existing development on Parcel C.


If you have any questions about this transmittal, Contact David Jellen at (520) 837-4082 or by email David.Jellen@tucsonaz.gov or contact Steve Shields at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat.
03/06/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
03/09/2020 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
03/19/2020 DJELLEN1 ENGINEERING REVIEW Reqs Change Provide a legible survey together with the legal descriptions that has all distance and bearing information labeled legibly. The legal descriptions should match the scope of the work of this project.
03/23/2020 SBEASLE1 ZONING-RECORDATION REVIEW Reqs Change LAND SPLIT PLAN RETURNED FOR CORRECTIONS NOTICE
Note: Payment and a resubmittal with a Comment Response Letter is required.

PERMIT: S20-015
DESCRIPTION: LAND SPLIT - Little Group, 5642 and 5636 S. Alvernon Way.
FEES DUE: $99.00
Note: Prior to accepting a resubmittal, we require payment in full.

Payment options: 1. Online Payment

Online Payment
https://www.tucsonaz.gov/pdsd/online-resources-fees-maps-records
1. NOTE: It may take 1-2 days for complete permit information to be available online
2. Visa, MC, Discover, American Express or pay by checking account
3. Not case-sensitive but a hyphen is needed, for example: dp19-2000
4. Enter your Permit Nbr
5. Business/Individual Name: Leave blank
6. Click the blue Continue tab
7. If any issues, try using the browser Internet Explorer

SEE REVIEWER'S COMMENTS and your submitted documentson PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, left side, Activity Search, enter the Activity Number
- Permits section, click on blue tab
- Reviews section, click on Review Details
- Documents section, click on blue icon to the right of each document

YOUR NEXT STEPS: Submit the following items to the Filedrop - https://www.tucsonaz.gov/file-upload-pdsd
1) Comment Response Letter (your response to the reviewer's Requires Change comments)
2) Any other items requested by reviewers

After your resubmittal, the Land Split Plan will enter a new 5-working-day review cycle.

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
Attn: Permit Counter
201 N. Stone Avenue, 2nd Floor
Tucson, AZ 85701
email: COTDSDPermits@TucsonAz.gov




NOTE:

The City of Tucson's Permit Counter at 201 N. Stone Avenue is closed to the public until further notice.

In the meantime, our office is still fully staffed but all communications will be via telephone or email.

City of Tucson updates: https://www.tucsonaz.gov/manager/covid-19-updates
03/23/2020 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved This one is not a Tucson Water customer, but Tucson Water approved this lot split.
Thanks,
Ray Munoz
Ray.Munoz@Tucsonaz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
03/23/2020 SBEASLE1 OUT TO CUSTOMER Completed