Plan Review Detail
Review Status: Completed
Review Details: LOT SPLIT REVIEW
Plan Number - S20-015
Review Name: LOT SPLIT REVIEW
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
02/27/2020 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
03/04/2020 | DJELLEN1 | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Jellen PDSD Zoning Review Section PROJECT: 5642 S. Alvernon Land Split (1st Review) S20-015 TRANSMITTAL DATE: March 4,, 2020 DUE DATE: March 5, 2020 COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) 8.3.1 Land Split and Administrative Manual (AM) Section 2-08. Also compliance with applicable development criteria for the proposed or existing use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). 8.3.1. LAND SPLIT 2-08.5.0 CONTENT REQUIREMENTS The drawing showing the proposed land split shall include the following: A. The proposed lots with distance and bearings labeled; COMMENT: Provide a legible survey together with the legal descriptions that has all distance and bearing information labeled legibly. Remove the property line so that Parcel A and B are shown as they will be as one parcel. Rename Parcel A and B so that they have one name. COMMENT: Clarify that Parcel 140-05-033F is remaining as a separate parcel. COMMENT: The provided legal descriptions inaccurately describe Parcel B as if it is being created as a new, unique Parcel rather than as a combined Parcel with Parcel A. The legal descriptions should describe the new boundaries of the two newly adjusted parcels. B. The rights-of-way adjacent to or within the property, including streets and easements. The streets and easements must be labeled, dimensioned and purpose listed; COMMENT: If applicable, provide all relevant easement information for the project location as noted by the standard above. C. The locations and dimensions of any existing structures and buildings; COMMENT: Provide a supplemental site plan for the existing development on Parcel C. If you have any questions about this transmittal, Contact David Jellen at (520) 837-4082 or by email David.Jellen@tucsonaz.gov or contact Steve Shields at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat. |
03/06/2020 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
03/09/2020 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
03/19/2020 | DJELLEN1 | ENGINEERING | REVIEW | Reqs Change | Provide a legible survey together with the legal descriptions that has all distance and bearing information labeled legibly. The legal descriptions should match the scope of the work of this project. |
03/23/2020 | SBEASLE1 | ZONING-RECORDATION | REVIEW | Reqs Change | LAND SPLIT PLAN RETURNED FOR CORRECTIONS NOTICE Note: Payment and a resubmittal with a Comment Response Letter is required. PERMIT: S20-015 DESCRIPTION: LAND SPLIT - Little Group, 5642 and 5636 S. Alvernon Way. FEES DUE: $99.00 Note: Prior to accepting a resubmittal, we require payment in full. Payment options: 1. Online Payment Online Payment https://www.tucsonaz.gov/pdsd/online-resources-fees-maps-records 1. NOTE: It may take 1-2 days for complete permit information to be available online 2. Visa, MC, Discover, American Express or pay by checking account 3. Not case-sensitive but a hyphen is needed, for example: dp19-2000 4. Enter your Permit Nbr 5. Business/Individual Name: Leave blank 6. Click the blue Continue tab 7. If any issues, try using the browser Internet Explorer SEE REVIEWER'S COMMENTS and your submitted documentson PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, left side, Activity Search, enter the Activity Number - Permits section, click on blue tab - Reviews section, click on Review Details - Documents section, click on blue icon to the right of each document YOUR NEXT STEPS: Submit the following items to the Filedrop - https://www.tucsonaz.gov/file-upload-pdsd 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Any other items requested by reviewers After your resubmittal, the Land Split Plan will enter a new 5-working-day review cycle. Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services Attn: Permit Counter 201 N. Stone Avenue, 2nd Floor Tucson, AZ 85701 email: COTDSDPermits@TucsonAz.gov NOTE: The City of Tucson's Permit Counter at 201 N. Stone Avenue is closed to the public until further notice. In the meantime, our office is still fully staffed but all communications will be via telephone or email. City of Tucson updates: https://www.tucsonaz.gov/manager/covid-19-updates |
03/23/2020 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Approved | This one is not a Tucson Water customer, but Tucson Water approved this lot split. Thanks, Ray Munoz Ray.Munoz@Tucsonaz.gov |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
03/23/2020 | SBEASLE1 | OUT TO CUSTOMER | Completed |