Plan Number: S20-009
Parcel: Unknown

Address:
5001 N ORACLE RD

Review Status: Completed

Review Details: LOT SPLIT REVIEW

Plan Number - S20-009
Review Name: LOT SPLIT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/03/2020 SBEASLE1 START PLANS SUBMITTED Completed
02/03/2020 JGARCIA1 BUILDING-COMMERCIAL REVIEW Approved
02/04/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
02/05/2020 SAMUEL ROGERS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Samuel Rogers
PDSD Zoning Review Section

PROJECT: Fiesta Plaza 5001 N Oracle Rd.
Land Split (1st Review)
S20-009

TRANSMITTAL DATE: 2/5/2020

DUE DATE: 2/7/2020

COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) 8.3.1 Land Split and Administrative Manual (AM) Section 2-08. Also compliance with applicable development criteria for the proposed or existing use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

8.3.1. LAND SPLIT

A. Purpose

According to A.R.S. ยง9-463.01(T), the City may regulate a land split as defined in Section 11.4.13 within its jurisdictional limits. The state law gives the City authority to determine the division lines, area, and shapes of the parcels. Neither a tentative plat nor a final plat is required but the resulting tracts or parcels shall conform to applicable zoning requirements and other government codes and ordinances. The purpose of this section is to establish a review process for land splits. This review:

Comment: Provide the activity number S20-009 on the plan.

2-08.3.0 APPLICATION SUBMITTAL REQUIREMENTS
Land split application packets are available at the Planning and Development Services Department (PDSD). Completed applications and accompanying materials shall be submitted to PDSD. Incomplete or inaccurate applications will not be accepted.

3.8 Fees in accordance with Section 4-01.0.0, Development Review Fee Schedule.

Comment: There appears to be $99 fee balance; all fees must be paid prior to the lot split's final approval.

2-08.5.0 CONTENT REQUIREMENTS
The drawing showing the proposed land split shall include the following:

B. The proposed lots with distance and bearings labeled;

Comment: For 105-03-032B; the curve "C3" does not appear to be in the line table.

Comment: For 105-03-032B; the curve "C10" does not appear on the survey drawing.

Comment: For 105-03-032F; the line "L15" had a distance of 92.73' on the line table and 92.75' on the legal description.

Comment: For 105-03-032F; the curve "C2" on the line table has a radius of 1859.88' and 1859.86 on the legal description.

C. The rights-of-way adjacent to or within the property, including streets and easements. The streets and easements must be labeled, dimensioned and purpose listed;

Comment: Dimension the right-of-ways adjacent to the property.

D. All proposed easements on and surrounding the property;

Comment: If applicable, indicate the location of all easements on and surrounding the property.


If you have any questions about this transmittal, Contact Samuel Rogers at (520) 837-6932 or by email Samuel.Rogers@tucsonaz.gov or contact Steve Shields at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat.
02/06/2020 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved Tucson Water approves the lot split.
Thanks,
Ray Munoz
Tucson Water
Ray.Munoz@Tucsonaz.gov
02/11/2020 LOREN MAKUS ENGINEERING REVIEW Approved
02/12/2020 SBEASLE1 ZONING-RECORDATION REVIEW Reqs Change LAND SPLIT PLAN
RETURNED FOR CORRECTIONS NOTICE
A resubmittal with a Comment Response Letter is required.

NOTE: All City of Tucson offices will be closed on Monday, February 17 (except for emergency services). Planning & Development Services will re-open on Tuesday: https://www.tucsonaz.gov/pdsd/contact-us-hours-service.

OVER-THE-COUNTER REVIEWS
1. May be available for some City reviews - at the City staffs discretion
2. Before visiting the City office, please contact the reviewers via phone or email
3. For contact information, see the reviewer's comments in PRO: www.tucsonaz.gov/pro.
4. PDSD hours: https://www.tucsonaz.gov/pdsd/contact-us-hours-service
5. Sign in at the receptionist desk (computer)

PERMIT: S20-009
Please include this number on all future correspondence and in Filedrop's "Project Description" field.

DESCRIPTION: LAND SPLIT - Fiesta Plaza.
FEE BALANCE: $0 (zero)
VIEW REVIEWER'S COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, left side, Activity Search, enter the Activity Number
- Permits section, click on blue tab
- Documents section, click on blue icon to the right of each document
- Reviews section, click on "Review Details"

YOUR NEXT STEPS: Submit the following items to the Filedrop - https://www.tucsonaz.gov/file-upload-pdsd
(In the Project Description field, enter the Activity Number.)
1) Comment Response Letter (your response to the reviewer's Requires Change comments)
2) Any other items requested by reviewers

After your resubmittal, the Land Split Plan will enter a new 5-working-day review cycle.
Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
Attn: Permit Counter/Payments
201 N. Stone Avenue, 3rd Floor
Tucson, AZ 85701
email: COTDSDPermits@TucsonAz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
02/12/2020 SBEASLE1 OUT TO CUSTOMER Completed