Plan Number: S20-003
Parcel: Unknown

Review Status: Completed

Review Details: LOT SPLIT REVIEW

Plan Number - S20-003
Review Name: LOT SPLIT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/13/2020 SBEASLE1 START PLANS SUBMITTED Completed
01/15/2020 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved Tucson Water approves this lot split.
Thank you,
Ray Munoz
Tucson Water
Ray.Munoz@tucsonaz.gov
01/15/2020 SAMUEL ROGERS ZONING REVIEW Reqs Change FROM: Samuel Rogers - Planner
PDSD Zoning Review Section

PROJECT: S20-003
Lot Line Reconfiguration (1st Review)
4340, 4330 N Mainard Dr. (Address)

TRANSMITTAL DATE: 1/15/20

DUE DATE: 1/21/20

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.


01. COMMENT: How will vehicles ingress and egress 10821008A without driving on 10821008B? If ingress/egress is proposed to cross 10821008B a access easement will be required.


02. COMMENT: The building setback requirement along the southern lot line is 6' or 2/3 the wall height of the structure. Building heights are needed to determine setback requirements. Wall height is measured from design grade to the midpoint of a slanted roof. Provide the wall height on the next submittal. . Model plans can be found on https://www.tucsonaz.gov/PRO/pdsd/ by searching for activity number: H000011203.


If you have any questions about this transmittal, contact Samuel Rogers at (520)837-6932 or at Samuel. Rogers@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans
01/16/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed .
01/21/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Show the point of connection to the existing public sewer for 4340 N Mainard Drive or, if an on-site sewage disposal system is serving 4340 N Mainard Drive, show the location of all individual components for the disposal system, including any reserve areas and indicate the required separation distances.
01/23/2020 LOREN MAKUS ENGINEERING REVIEW Reqs Change S20-003 - Lot Reconfiguration
This lot reconfiguration cannot be approved. The Original City Zoning for this parcel (C15-88-04) requires a minimum lot size of 36,000 square feet. The Original City Zoning is still effective. One of the following is required.
1. Provide evidence the lot split recorded in 2005 was approved by the City of Tucson Planning and Development Services Department.
2. Combination of the two parcels back to the original parcel. Or
3. Obtain a change of conditions for the Original City Zoning. For questions on the zoning and the process for obtaining a change of conditions you may contact John Beall (john.beall@tucsonaz.gov) or Michael Wyneken (michael.wyneken@tucsonaz.gov).
Loren Makus
loren.makus@tucsonaz.gov
01/24/2020 SBEASLE1 ZONING-RECORDATION REVIEW Reqs Change LAND SPLIT PLAN
RETURNED FOR CORRECTIONS NOTICE
Note: A resubmittal with a Comment Response Letter is required.

PERMIT: S20-003
Please include this number on all future correspondence and in Filedrop's "Project Description" field.

DESCRIPTION: LAND SPLIT - 4330 and 4340 N. Mainard Drive, lot line adjustment.

FEE BALANCE: $0 (zero)
VIEW DOCUMENTS and reviewer's comments online (PRO): www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, left side, Activity Search, enter the Activity Number
- Permits section, click on blue tab
- Documents section, click on blue icon to the right of each document
- Reviews section, click on "Review Details"

YOUR NEXT STEPS: Submit the following items to the Filedrop - https://www.tucsonaz.gov/file-upload-pdsd
(In the Project Description field, enter the Activity Number.)
1) Comment Response Letter (your response to the reviewer's Requires Change comments)
2) Any other items requested by reviewers

After your resubmittal, the Land Split Plan will enter a new 5-working-day review cycle.
Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
Attn: Permit Counter/Payments
201 N. Stone Avenue, 3rd Floor
Tucson, AZ 85701
email: COTDSDPermits@TucsonAz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
01/24/2020 SBEASLE1 OUT TO CUSTOMER Completed