Plan Review Detail
Review Status: Completed
Review Details: LOT SPLIT REVIEW
Plan Number - S20-003
Review Name: LOT SPLIT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/13/2020 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 01/15/2020 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Approved | Tucson Water approves this lot split. Thank you, Ray Munoz Tucson Water Ray.Munoz@tucsonaz.gov |
| 01/15/2020 | SAMUEL ROGERS | ZONING | REVIEW | Reqs Change | FROM: Samuel Rogers - Planner PDSD Zoning Review Section PROJECT: S20-003 Lot Line Reconfiguration (1st Review) 4340, 4330 N Mainard Dr. (Address) TRANSMITTAL DATE: 1/15/20 DUE DATE: 1/21/20 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 01. COMMENT: How will vehicles ingress and egress 10821008A without driving on 10821008B? If ingress/egress is proposed to cross 10821008B a access easement will be required. 02. COMMENT: The building setback requirement along the southern lot line is 6' or 2/3 the wall height of the structure. Building heights are needed to determine setback requirements. Wall height is measured from design grade to the midpoint of a slanted roof. Provide the wall height on the next submittal. . Model plans can be found on https://www.tucsonaz.gov/PRO/pdsd/ by searching for activity number: H000011203. If you have any questions about this transmittal, contact Samuel Rogers at (520)837-6932 or at Samuel. Rogers@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans |
| 01/16/2020 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Completed | . |
| 01/21/2020 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Show the point of connection to the existing public sewer for 4340 N Mainard Drive or, if an on-site sewage disposal system is serving 4340 N Mainard Drive, show the location of all individual components for the disposal system, including any reserve areas and indicate the required separation distances. |
| 01/23/2020 | LOREN MAKUS | ENGINEERING | REVIEW | Reqs Change | S20-003 - Lot Reconfiguration This lot reconfiguration cannot be approved. The Original City Zoning for this parcel (C15-88-04) requires a minimum lot size of 36,000 square feet. The Original City Zoning is still effective. One of the following is required. 1. Provide evidence the lot split recorded in 2005 was approved by the City of Tucson Planning and Development Services Department. 2. Combination of the two parcels back to the original parcel. Or 3. Obtain a change of conditions for the Original City Zoning. For questions on the zoning and the process for obtaining a change of conditions you may contact John Beall (john.beall@tucsonaz.gov) or Michael Wyneken (michael.wyneken@tucsonaz.gov). Loren Makus loren.makus@tucsonaz.gov |
| 01/24/2020 | SBEASLE1 | ZONING-RECORDATION | REVIEW | Reqs Change | LAND SPLIT PLAN RETURNED FOR CORRECTIONS NOTICE Note: A resubmittal with a Comment Response Letter is required. PERMIT: S20-003 Please include this number on all future correspondence and in Filedrop's "Project Description" field. DESCRIPTION: LAND SPLIT - 4330 and 4340 N. Mainard Drive, lot line adjustment. FEE BALANCE: $0 (zero) VIEW DOCUMENTS and reviewer's comments online (PRO): www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, left side, Activity Search, enter the Activity Number - Permits section, click on blue tab - Documents section, click on blue icon to the right of each document - Reviews section, click on "Review Details" YOUR NEXT STEPS: Submit the following items to the Filedrop - https://www.tucsonaz.gov/file-upload-pdsd (In the Project Description field, enter the Activity Number.) 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Any other items requested by reviewers After your resubmittal, the Land Split Plan will enter a new 5-working-day review cycle. Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services Attn: Permit Counter/Payments 201 N. Stone Avenue, 3rd Floor Tucson, AZ 85701 email: COTDSDPermits@TucsonAz.gov |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/24/2020 | SBEASLE1 | OUT TO CUSTOMER | Completed |