Review Status: Completed
Review Details: LOT SPLIT REVIEW
Plan Number - S19-086
Review Name: LOT SPLIT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/06/2019 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 12/09/2019 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Completed | |
| 12/09/2019 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Reqs Change | Tucson Water does not accept this lot split. The owner/developer will need to make the necessary provisions to the existing water plan in order to show the meters for each of these lots will not cause a remote meter. Thanks, Ray Munoz Tucson Water Ray.Munoz@TucsonAz.gov (520) 837-2207 |
| 12/10/2019 | SAMUEL ROGERS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Samuel Rogers PDSD Zoning Review Section PROJECT: Lot Reconfiguration 2549, 2557, and 2565 E Calle Palta Land Split (1st Review) S19-086 TRANSMITTAL DATE: 12/10/2019 DUE DATE: 12/13/2019 COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) 8.3.1 Land Split and Administrative Manual (AM) Section 2-08. Also compliance with applicable development criteria for the proposed or existing use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). 8.3.1. LAND SPLIT A. Purpose According to A.R.S. §9-463.01(T), the City may regulate a land split as defined in Section 11.4.13 within its jurisdictional limits. The state law gives the City authority to determine the division lines, area, and shapes of the parcels. Neither a tentative plat nor a final plat is required but the resulting tracts or parcels shall conform to applicable zoning requirements and other government codes and ordinances. The purpose of this section is to establish a review process for land splits. This review: 1. COMMENT: A survey drawing with the bearing and degrees and proposed lot sizes are required for review of the lot reconfiguration proposal. 2. COMMENT: Add a note on the plan that a separate plot plan will be required to be submitted at the time of permitting. If you have any questions about this transmittal, Contact Samuel Rogers at (520) 837-6932 or Samuel.Rogers@tucsonaz.gov or contact Steve Shields at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat. |
| 12/17/2019 | SBEASLE1 | ZONING-RECORDATION | REVIEW | Reqs Change | LAND SPLIT PLAN RETURNED FOR CORRECTIONS NOTICE - A resubmittal is required Permit/Activity Number: S19-086 Include this number on all future correspondence. Project Description: Land Split/Reconfiguration - Tres Pueblos Este, Lots 14-16. Fees Due: $99.00 Note: Prior to accepting a resubmittal, we require payment in full. Please pay: 1. Online Payment 2. In person at the City Permit Counter (Mon-Fri, 8:00 AM to 2:00 PM) 3. By mail - a check payable to the City of Tucson (address is below), include the Activity Number Online Payment https://www.tucsonaz.gov/pdsd/online-resources-fees-maps-records 1. Total fees due: May take 1-2 days for information to be available 2. Visa, MC, Discover, American Express 3. Not case-sensitive but a hyphen is needed, for example: dp19-2000 4. Enter your Permit Nbr. and click the “Continue” tab 5. Business/Individual Name: Leave blank 6. If any issues, try using the browser Internet Explorer To view documents and reviewer's comments: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, left side, Activity Search, enter the Activity Number - Permits section, click on blue tab - Documents section, click on blue icon to the right of each document - Reviews section, click on "Review Details" Submit the following items to the Filedrop. In the Project Description field, enter the Activity Number. PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd 1) Comment Response Letter (your response to the reviewer's “Requires Change” comments) 2) Any other items requested by reviewers After your resubmittal, the Land Split Plan will enter a new 5-working-day review cycle. Thank you. HOLIDAY SCHEDULE: First floor Plan Review counters and Cashier Services will be closed during Christmas week, Dec. 23-27. However, the Permit counter will be closed only on Dec. 25, and open the rest of the week from 8am-2pm, phone (520) 791-5550, press O for an operator. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services Attn: Permit Counter/Payments 201 N. Stone Avenue, 3rd Floor Tucson, AZ 85701 |
| 12/17/2019 | LOREN MAKUS | ENGINEERING | REVIEW | Reqs Change | Provide an exhibit showing lot size, lot dimension and lot lines with distance and bearing for the proposed lot configuration. |
| 12/17/2019 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/17/2019 | SBEASLE1 | OUT TO CUSTOMER | Completed |