Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Plan Number: S19-083
Parcel: Unknown

Address:
1970 S EUCLID AV

Review Status: Completed

Review Details: LOT SPLIT REVIEW

Plan Number - S19-083
Review Name: LOT SPLIT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/04/2019 SBEASLE1 START PLANS SUBMITTED Completed
12/05/2019 DAVID RIVERA H/C SITE REVIEW Approved
12/05/2019 DAVID RIVERA ZONING REVIEW Reqs Change FROM: David Rivera
PDSD Zoning Review Section

PROJECT: S19-083 (Existing Commercial Storage Use)
Commercial Land Split (1st Review)
710 E. Silverlake Road - P-I Zoning

TRANSMITTAL DATE: December 5, 2019

DUE DATE: December 10, 2019

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.


01. COMMENT: 2-08.5.0 - Zoning has reviewed the proposed Land Split for compliance with the UDC requirements of section 2-08.5.0 but cannot approve the application on this review. Address the following zoning comments and resubmit for plan review.


02. COMMENT: 2-08.5.0.E - Clearly define the building footprint and label the building dimensions for both existing buildings as noted by the standard.


03. COMMENT: 2-08.5.0.G - Label the square footage and acreage of each proposed lot must be labeled on each sheet 2 within the new lot boundary.


04. COMMENT: 2-08.5.0.H - Clarify if there will be cross access between the two new parcels, if so label, delineate and dimension the cross access easement area. A Separate easement document must be recorded and provided with the land split documents on the next submittal and prior to approval by zoning.


05. COMMENT: 2-08.5.0.I - Per the plan there appears to be a proposed 8' wide access opening with Ramp. There must be a 2 Hour fire rated wall between commercial structures. In addition, it is not clear if this opening is to remain or to be closed off as part of the land split. Approval by the PDSD Structural Plans Reviewer is required for this item before Zoning can approve the land split.


***For additional information on the any standard presented in this memo, please refer to the City of Tucson "Unified Development Code" - Administrative Manual Section 2-08 or Technical Standards noted in the comments. https://www.tucsonaz.gov/pdsd/all-codes-plans-determinations



If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov
12/10/2019 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
12/10/2019 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
12/11/2019 LOREN MAKUS ENGINEERING REVIEW Approved
12/12/2019 SBEASLE1 ZONING-RECORDATION REVIEW Reqs Change LAND SPLIT PLAN RETURNED FOR CORRECTIONS NOTICE
- A resubmittal is required
Permit/Activity Number: S19-083
Include this number on all future correspondence.

Project Description: LAND SPLIT - HOBO2 Arizona Realty.

Fee Balance: $0 (zero)
To view documents and reviewer's comments: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, left side, Activity Search, enter the Activity Number
- Permits section, click on blue tab
- Documents section, click on blue icon to the right of each document
- Reviews section, click on "Review Details"

Submit the following items to the Filedrop.
In the Project Description field, enter the Activity Number.
PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd
1) Comment Response Letter (your response to the reviewer's “Requires Change” comments)
2) Any other items requested by reviewers

After your resubmittal, the Land Split Plan will enter a new 5-working-day review cycle.
Thank you.

HOLIDAY SCHEDULE: All Plan Review counters will be closed during Christmas week, Dec. 23-27. However, the Permit counter will be closed only on Dec. 25, and open the rest of the week from 8am-2pm, phone (520) 791-5550 press “O” for an operator.

Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
Attn: Permit Counter/Payments
201 N. Stone Avenue, 3rd Floor
Tucson, AZ 85701
12/12/2019 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
12/12/2019 SBEASLE1 OUT TO CUSTOMER Completed