Plan Review Detail
Review Status: Completed
Review Details: LOT SPLIT REVIEW
Plan Number - S19-082
Review Name: LOT SPLIT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/26/2019 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 11/27/2019 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 12/03/2019 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 12/03/2019 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Approved | Tucson Water approves lot split. Thanks, Ray Munoz Ray.Munoz@TucsonAz.gov |
| 12/04/2019 | PAUL CAMARENA | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Paul Camarena PDSD Zoning Review Section PROJECT: 7920 S. Kolb Road, Land Split Land Split (1st Review) 7920 S KOLB RD S19-082 - I-2 Zoning TRANSMITTAL DATE: December 04, 2019 COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) 8.3.1 Land Split and Administrative Manual (AM) Section 2-08. Also compliance with applicable development criteria for the proposed or existing use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). 8.3.1. LAND SPLIT A. Purpose According to A.R.S. §9-463.01(T), the City may regulate a land split as defined in Section 11.4.13 within its jurisdictional limits. The state law gives the City authority to determine the division lines, area, and shapes of the parcels. Neither a tentative plat nor a final plat is required but the resulting tracts or parcels shall conform to applicable zoning requirements and other government codes and ordinances. The purpose of this section is to establish a review process for land splits. This review: 1. Assures that newly created tracts or parcels are of sufficient size to be developed and meet the requirements of applicable zoning classification; 2. Assures that the newly created tracts or parcels have locations for building pads that are protected from flood and erosion hazards as defined in the Floodplain Ordinance (Tucson Code Chapter 26) and Standards Manual for Drainage Design and Floodplain Management in Tucson, Arizona; and, 3. Assures that all tracts or parcels resulting from a land split shall have adequate access as specified by Section 7.8, Access, of the UDC , Sections 7-01.0.0, Pedestrian Access, and 10-01.0.0, Street Technical Standard, of the Technical Standards Manual and City of Tucson Drainage Manuals. 2-08.5.0 CONTENT REQUIREMENTS The drawing showing the proposed land split shall include the following: B. The proposed lots with distance and bearings labeled; COMMENT: Draw and Label distance and bearing for "Thence S 89°37'55" W along the East line of Lot 2 a distance of 1.00 Feet to a corner of Lot 2;" on the survey drawing. Also, draw and label the distance and bearing for the proposed ingress and egress easement. It is acknowledged that there is little space, a line table is highly recommended. If you have any questions about this transmittal, Contact Paul Camarena at (520) 837-4082 or by email Paul.Camarena@tucsonaz.gov or contact Steve Shields at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat. |
| 12/04/2019 | PCAMARE1 | H/C SITE | REVIEW | Reqs Change | See Zoning Comment |
| 12/09/2019 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Approved | |
| 12/10/2019 | SBEASLE1 | ZONING-RECORDATION | REVIEW | Reqs Change | LAND SPLIT PLAN RETURNED FOR CORRECTIONS NOTICE - A resubmittal is required Permit/Activity Number: S19-082 Include this number on all future correspondence. Project Description: LAND SPLIT - 7920 S. Kolb Road. Fee Balance: $0 (zero). To view documents and reviewer's comments: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, left side, “Activity Search”, enter the Activity Number - “Permits” section, click on blue tab - “Documents” section, click on blue icon to the right of each document - "Reviews" section, click on "Review Details" Submit the following items to the Filedrop. In the Project Description field, enter the Activity Number. PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd 1) Comment Response Letter (your response to the reviewer's “Requires Change” comments) 2) Any other items requested by reviewers After resubmittal, the Land Split Plan will enter a new 5-working-day review cycle. Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services Attn: Permit Counter/Payments 201 N. Stone Avenue, 3rd Floor Tucson, AZ 85701 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/10/2019 | SBEASLE1 | OUT TO CUSTOMER | Completed |