Plan Review Detail
Review Status: Completed
Review Details: MINOR SUBDIVISION REVIEW
Plan Number - S19-080
Review Name: MINOR SUBDIVISION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/01/2021 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 03/01/2021 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Approved | Approved. See the document: "Tucson Water, availability letter, 01.16.2020". |
| 03/22/2021 | SBLOOD1 | ENGINEERING | REVIEW | Reqs Change | 1. Please reference AM section 2-07 regarding font size so that all information is legible. 2. Previous comment #2 not addressed - The final plat only contains 2 sheets. The provided 3rd page is a supplemental site plan that will not be recorded. Please update so that the final plat only has 2 sheets. 3. Previous comment #5 not addressed - Update the approval signature block to the year 2021 4. State "FINAL PLAT" in the title and title block of the Cover Sheet. 5. Previous comment #8 not addressed - Please reference AM section 2-07 regarding format, sheet size, and margin requirements. Review and Comments provided by third party engineer reviewers under contract with the City of Tucson. For Questions or Concerns contact: Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
| 04/01/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL FROM: PDSD Zoning Review PROJECT: Bryant Minor Subdivision Final Plat (2nd Review) S19-080 TRANSMITTAL DATE: April 1, 2021 DUE DATE: March 25, 2021 COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-07. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). 5.1 General Previous Comment 1. This comment was not addressed. Clarify what the second sheet is for as it is identical to sheet 1. The plat should only be 2 sheets, sheet 1 & 2. Sheet 3 should be a separate supplemental sheet. COMMENT: Combine all of the sheets into one document for the next submittal. Move the sheet number location to the lower right corner of each sheet. Clarify the necessity for sheet 2A and if it is the same as sheet 2, remove it from the next submittal. Previous Comment 10. As this plat has not been resubmitted and will not be recorded until 2021 revise the approval year to 2021. COMMENT: Revise the year of the approval of the document on sheet 1 from 2019 to 2021. Previous Comment 11. This comment was not addressed. COMMENT: Add a signature location for the "City of Tucson Planning and Development Services Department Director" as noted by the standard above. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin @tucsonaz.gov or (520) 837-4966 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat. |
| 04/06/2021 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Reqs Change | FROM: Julieann Arechederra, GIS Cartographer Pima County Assessor's Office DATE: April 6, 2021 RE: Assessor's Review and Comments Regarding: BRYANT SPLIT MINOR SUB S19-080 FINAL PLAT(2nd) ___X___ Plat does not meet Assessor's Office requirements. COMMENTS: GENERAL NOTES MUST HAVE THE GROSS AREA OF THE SUBDIVISION, THE NUMBER OF LOTS, THE NUMBER OF MILES OF NEW ROAD, PUBLIC OR PRIVATE, EVEN IF THE NUMBER IS 0, AND THE BASIS OF BEARING. |
| 04/07/2021 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | DATE: April 7, 2021 Returned for Corrections PERMIT/ACTIVITY: S19-080 DESCRIPTION: Minor Subdivision - 1150 N. Bryant Avenue. FEE BALANCE: $0 (zero) Thank you for the payment. RESUBMITTAL Submit the following documents to: https://docs.tucsonaz.gov/Forms/tucsonpermitapp (Select "Existing Application", then the permit number) 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff - Title your 3rd submittal documents starting with the submittal number, for example: 3_Comment Response Letter, 01.01.21 SEE REVIEW COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews - click on Review Details - Documents - click on View to the right of each document Thank you. City of Tucson Attn: Sharon Beasley, Permit Specialist Planning and Development Services email: COTDSDPermits@TucsonAz.gov (Disregard the automatic reply you will receive: "This email account is not...") |