Plan Review Detail
Review Status: Completed
Review Details: MINOR SUBDIVISION REVIEW
Plan Number - S19-076
Review Name: MINOR SUBDIVISION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/30/2019 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 10/30/2019 | SBEASLE1 | UTILITIES | SOUTHWEST GAS | Passed | Review not required. This agency was notified for their information only. |
| 10/30/2019 | SBEASLE1 | OTHER AGENCIES | U. S. POST OFFICE | Passed | Review not required. This agency was notified for their information only. |
| 10/30/2019 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Reqs Change | The Applicant is responsible for obtaining a Water Availability Letter from Tucson Water (or Ray Water Company, if applicable). Provide the Letter in resubmittal. Mayor & Council cannot approve until water is assured. |
| 10/30/2019 | SBEASLE1 | OTHER AGENCIES | PIMA ASSN OF GOVTS | Passed | Review not required. This agency was notified for their information only. |
| 11/01/2019 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approved | TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) GIS Cartographer Pima County Assessor's Office DATE: November 1, 2019 RE: Assessor's Review and Comments Regarding: 30TH ST MINOR SUBDIVISION -S19076- 1ST FINAL PLAT REVIEW X Plat meets Assessor's Office requirements. |
| 11/19/2019 | PAUL CAMARENA | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Paul Camarena PDSD Zoning Review Section PROJECT: 30th Street Minor Subdivision Final Plat (1st Review) 6002 E 30TH S19-076 - R-1 Zoning TRANSMITTAL DATE: November 18, 2019 COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-07. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Final plats, block plats, minor subdivisions, and condominium plats shall be prepared according to the requirements provided below. Hereafter referred to as "plat" or "plats." A final plat serves as a survey document suitable for recordation of all or part of an approved tentative plat, if applicable. The final plat must conform to the approved tentative plat or site plan in lot configuration, design, and required conditions of development. The final plat, once approved, is recorded in the Pima County Recorder's Office. The final plat is kept on file and becomes part of the permanent record for the subject site. (Am. Admin. Directive, 5/14/2013) 2-07.3.0 SUBMITTAL TIMING Review of final plats is normally initiated after the tentative plat has been approved, unless concurrent tentative and final plat submittal has been approved by the PDSD prior to submittal. Final plats may also be submitted for review prior to the approval of a tentative if a minimum of one review of the tentative plat have occurred. In any case, submittal of the final plat prior to approval of the tentative plat is done at the applicant's risk since changes could be required of the tentative that may affect the final plat. 2-07.4.0 FORMAT REQUIREMENTS Plats must: 4.1 Be on a 24-inch by 36-inch sheet(s) folded to the eight and one-half inch by 11-inch format shown in Exhibit I. The plat may comprise several sheets showing various elements of required data; 4.2 Be prepared on materials that can be transferred to double-matt Mylar reverse read; 4.3 Have a two-inch margin on the left side and one-half inch margins on the remaining sides to comply with standardization requirements of state law for recorded plats; 4.4 Be drawn to a scale of no more than one inch equals 40 feet; and, 4.5 All lettering and dimensions shall be three-thirty-seconds inch in height. 2-07.5.0 CONTENT REQUIREMENTS 2-07.5.1.A.3 Subdivisions, arterial and collector streets, major watercourses, and railroads within the one-mile area; and, 1. COMMENT: Label the subdivision as noted by the standard above. It appears that Wilmot Rd and Craycroft Rd are in the incorrect location. 2-07.5.1.E Provide a title block in the lower right corner of each sheet with the following information: 2-07.5.1.E.1 Subdivision name; number of blocks, lots, and/or units; and common area; 2. COMMENT: Revise subdivision name to state " Minor Subdivision" instead of Final Plat 2-07.5.1.F Orient the subdivision drawing with north toward the top of the page, when possible. Place a north arrow on each sheet in the upper right corner with the scale of the drawing beneath the arrow. All lettering, dimensions, etc., must be oriented to the north. If it is not practical to orient north to the top of the sheet, the plan drawing shall be oriented with north to the left side of the sheet. 3. COMMENT: The drawing is oriented with north to the right side of the sheet revise so that north is to the left side of the sheet as noted by the standard above. 2-07.5.2.J If applicable, add the following note: "This subdivision is subject to Ordinance No. ____ which established zoning in the _____________________ Annexation Area." 4. COMMENT Add the above statement and fill in the blanks accordingly; ordinance "# 1895 " and annexation name "- North To Roger Rd. And East To Kolb Rd." 2-07.5.4 Proposed Subdivision Information Provide the following information on the plat: 2-07.5.4.A. Indicate the name and width of each street, alley, easement (type), and drainage way within the subdivision boundary being created by this plat. Label each as public or private, along with the appropriate dedication notation; 5. COMMENT: Provide the information noted by the standard above. 2-07.5.4.D. Provide location, dimensions, areas in square footage, and purposes of lots proposed for dedication (such as open spaces, recreation areas, and natural areas) or for reservation for a public use (such as public parks, water facilities, and school sites); 2-07.5.4.E. Show required setbacks, such as erosion hazard, drainage, etc.; 2-07.5.4.F. Show the limits of the 100-year flood prone area in a surveyable and readily retraceable manner with frequent ties to intersecting lot lines for all flows of 100 cfs or more; 6. COMMENT: Provide a supplemental set plan sheet that includes all the buildings and setbacks to the new property lines and lot coverage 2-07.5.4.H. Show no-vehicular access easements where applicable; 7. COMMENT: If applicable provide the information noted by the standard above. If you have any questions about this transmittal, Contact Paul Camarena at (520) 837-4082 or by email Paul.Camarena@tucsonaz.gov or contact Steve Shields at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat. |
| 11/19/2019 | PCAMARE1 | ZONING HC | REVIEW | Approved | |
| 11/22/2019 | KAY MARKS | PIMA COUNTY | ADDRESSING | Approved | S19-076, 30th St. minor subdiv. / 1st submittal is Approved by Pima County Addressing. Thank you, Robin Freiman, Addressing Official Pima County Development Services Department 201 N Stone AV – 4th Floor Tucson, AZ 85701 (520) 724-7570 |
| 11/25/2019 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Approved | |
| 11/26/2019 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 11/27/2019 | SBEASLE1 | COT NON-DSD | PARKS & RECREATION | Approved | No existing or proposed Tucson Parks and Recreation facilities are affected by this minor subdivision. Howard B. Dutt, RLA Landscape Architect Tucson Parks & Recreation, (520) 837-8040 Howard.Dutt@tucsonaz.gov |
| 11/27/2019 | SBEASLE1 | UTILITIES | TUCSON ELECTRIC POWER | Reqs Change | (The "attached easement" mentioned below can be viewed on: www.TucsonAz.gov/Pro. See the "Documents" section.) Tucson Electric Power Co., (TEP) has reviewed the final plat submitted on October 30, 2019, and is unable to approve at this time. Please add the following to the plat: · The 16’ wide TEP easement along the west boundary of Lot 5, per attached easement recorded in Bk 8506 Pg 1482 · Add notation that the 10’ wide Utility Easement split between the southern boundary of Lot 5 and the northern boundary of Lot 16 is granted per Final Plat for Craycroft Annex Addition, Book 8, Page 36 of Maps and Plats. If there are any questions, please contact me at 520-917-8744. Thank you, Mary Burke, Senior Right of Way Agent Tucson Electric Power Co., Land Resources – RC 131 3950 E. Irvington Road, Tucson, AZ 85714-2114 Office - 520-917-8744, Cell - 520-401-9895, mburke@tep.com |
| 12/03/2019 | JIM EGAN | COT NON-DSD | FIRE | Approved | |
| 12/04/2019 | ROBERT SHERRY | PLUMBING-RESIDENTIAL | REVIEW | Reqs Change | 1. Verify that the new studio residence at 6008 E 30th Street will have an independent connection to the public sewer. Reference: Section 701.3, IPC 2018. 2. Provide the rim elevation of the next upstream sanitary manhole (5530-06) and the first floor elevation of the studio. Determine the need for a backwater valve per Section 714.1, IPC 2018, as amended by the City of Tucson. |
| 12/05/2019 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Reqs Change | S19-076 1) Clarify under whose direction the survey was performed and provide a seal and signature for that surveyor. If the Survey was done under the direction of Richard B Howell then a seal and signature from Richard B Howell should be shown. Please use the "CERTIFICATION OF SURVEY" block found in City of Tucson Administrative Manual section 2-07.5.3.A John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov 520-837-5007 |
| 12/05/2019 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | PLAN RETURNED FOR CORRECTIONS NOTICE - A resubmittal is required. Permit/Activity Number: S19-076 Include this number on all future correspondence. Project Description: MINOR SUBD, Final Plat - 6002 E. 30th St. Convert 2 parcels into 3 parcels. Fees Due: $ 1,116.50 (see image below). Note: We require a payment prior to accepting your next submittal. Please pay the total fees (or Review Fees at a minimum): 1. Online Payment (Not available for "DS.." permit numbers) 2. In person at the City Permit Counter (Mon-Fri, 8:00 AM to 2:00 PM) 3. By mail - a check payable to the City of Tucson (address is below), include the Activity Number Online Payment https://www.tucsonaz.gov/pdsd/online-resources-fees-maps-records 1. Total fees due: May take 1-2 days for information to be available 2. Visa, MC, Discover, American Express 3. Not case-sensitive but a hyphen is needed, for example: dp19-2000 4. Enter your Permit Nbr. and click the Continue tab 5. Business/Individual Name: Leave blank 6. If any issues, try using the browser Internet Explorer To view documents and Reviewer's comments: www.tucsonaz.gov/pro (If information is not available, check back later as data transfers to PRO periodically.) - Home page, left side, Activity Search, enter the Activity Number - Permits section, click on blue tab - Documents section, click on blue icon to the right of each document - Reviews section, click on "Review Details" Submit the following items to the Filedrop. In the Project Description field, enter the Activity Number. PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan Set (all pages, full set) 3) Any other documents requested by review staff 4) Name your 2nd submittal documents accordingly, for example: 2_Plan_Set Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services Attn: Permit Counter/Payments 201 N. Stone Avenue, 3rd Floor Tucson, AZ 85701 email: COTDSDPermits@TucsonAz.gov |
| 12/05/2019 | SBEASLE1 | PIMA COUNTY | WASTEWATER | Reqs Change | The Applicant is responsible for obtaining review and approval for wastewater from Pima County (email: Sewer@Pima.gov) prior to Mayor & Council approval of the final plat. Please provide an approval document in the next resubmittal. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/05/2019 | SBEASLE1 | OUT TO CUSTOMER | Completed |