Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - MINOR SUBD REVIEW
Plan Number - S19-075
Review Name: RESUBMITTAL - MINOR SUBD REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/28/2020 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Approved | See Water Availability Letter dated 01.28.2020 on file from Tucson Water Dept. |
| 02/28/2020 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 03/19/2020 | DAVID RIVERA | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera PDSD Zoning Review Section PROJECT: 1450 North Brown Avenue Lots 1 & 2 Final Plat (2nd Review) - 1450 N. Brown Avenue S19-075 - RX-1 Zoning TRANSMITTAL DATE: March 19, 2020 DUE DATE: March 27, 2020 COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-07. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Final plats, block plats, minor subdivisions, and condominium plats shall be prepared according to the requirements provided below. Hereafter referred to as "plat" or "plats." A final plat serves as a survey document suitable for recordation of all or part of an approved tentative plat, if applicable. The final plat must conform to the approved tentative plat or site plan in lot configuration, design, and required conditions of development. The final plat, once approved, is recorded in the Pima County Recorder's Office. The final plat is kept on file and becomes part of the permanent record for the subject site. (Am. Admin. Directive, 5/14/2013) The following comments are related to the supplemental site plan. Follow up to the previous site plan comment: The setback waiver text block must be filled out by the owner. It was not clear if the Ramada was to be relocated or removed, clarify. 1. COMMENT: Lot 1; all the accessory structures on Lot 1 must be removed prior to approval of the final plat. The supplemental site plan was reviewed as reference only. A separate plot plan, building plans and permit application is required for the proposed dwelling. A separate compliance review will be made at time of permit application for lot 1. Lot 2; The large Ramada structure that is crossing over the new property line must be relocated or removed to meet the 20 foot setback. The two smaller sheds within the 20 building setback adjacent to the new lot line must be relocated to meet the 20 foot setback. The option, to request the adjacent owner setback waiver, sees the statement below. The adjacent owner's waiver statement must be added to the site plan. The following statement can be used. "My Name is __________________ and I am the owner of the property located at ________________________. I have reviewed the site plan and I have no objection to structure being located or constructed ______ feet from the property line as depicted on the supplemental site plan." If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat. |
| 03/27/2020 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 03/30/2020 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | RETURNED FOR CORRECTIONS NOTICE Your Next Steps: Resubmittal with a Comment Response Letter DESCRIPTION: BLOCKPLAT - Shepherd Block Plat, Lots 1 and 2. PERMIT: S19-075 FEE BALANCE:$0 (zero) SEE REVIEWER'S COMMENTSand your submitted documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, left side, Activity Search, enter the Activity Number - Permits section, click on blue tab - Reviews section, click on Review Details - Documents section, click on blue icon to the right of each document YOUR NEXT STEPS:Submit the following items to the Filedrop - https://www.tucsonaz.gov/file-upload-pdsd 1) Comment Response Letter (your response to the reviewer's Requires Changecomments) 2) Plan Set (all pages, full set) 3) Any other documents requested by review staff - Name your 3rd submittal documents to start with the submittal number, for example: 3_Plan_Set Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services email: COTDSDPermits@TucsonAz.gov NOTE: The City of Tucson's Permit Counter at 201 N. Stone Avenue (the physical office) is closed to the public until further notice. In the meantime, our office is still fully staffed but all communications are by telephone or email. City of Tucson updates: https://www.tucsonaz.gov/manager/covid-19-updates |
| 03/30/2020 | SBEASLE1 | ZONING-RECORDATION | REVIEW | Passed | |
| 04/15/2020 | SBEASLE1 | PIMA COUNTY | WASTEWATER | Approved | See the Sewer Capacity Waiver document in PRO titled: " 2_Sewer availability letter, Pima Co. Wastewater". |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/30/2020 | SBEASLE1 | OUT TO CUSTOMER | Completed |