| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/18/2019 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 09/18/2019 | SBEASLE1 | UTILITIES | SOUTHWEST GAS | Passed | Review not required. This agency was notified for their information only. |
| 09/18/2019 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Reqs Change | FROM: Suzanne Gilpin, GIS Cartographer, Pima County Assessor's Office,(520)724-4387 DATE: September 18, 2019 RE: Assessor's Review and Comments Regarding Final Plat- S19-067-UHAUL AT BROADWAY & CAMINO SECO 1ST SUBMITTAL __X___ Plat does not meet Assessor's Office requirements. COMMENTS: - All streets must be named and have dimensions, bearings and curve data. - All Adjacent subdivisions should be named, with map and plat in the appropriate areas around the subdivision. - Notary block of Dedication indicates that Amerco Real Estate Co. may not be the entity signing final plat. If Pioneer Title Agency as Trustee is to be owner, please make sure that a Deed is recorded prior to recordation of plat. |
| 09/18/2019 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Passed | No review needed. Project involves less than six lots. |
| 09/18/2019 | SBEASLE1 | OTHER AGENCIES | U. S. POST OFFICE | Passed | Review not required. This agency was notified for their information only. |
| 09/18/2019 | SBEASLE1 | OTHER AGENCIES | PIMA ASSN OF GOVTS | Passed | Review not required. This agency was notified for their information only. |
| 09/19/2019 | MESCALA1 | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Martin Escalante PDSD Zoning Review Section PROJECT: UHaul at Broadway & Camino Seco Lots 1-3 Final Plat (1st Review) 8740 E Broadway BL S19-067 -Zoning C-1 TRANSMITTAL DATE: September 19, 2019 DUE DATE: October 16, 2019 COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-07. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Final plats, block plats, minor subdivisions, and condominium plats shall be prepared according to the requirements provided below. Hereafter referred to as "plat" or "plats." A final plat serves as a survey document suitable for recordation of all or part of an approved tentative plat, if applicable. The final plat must conform to the approved tentative plat or site plan in lot configuration, design, and required conditions of development. The final plat, once approved, is recorded in the Pima County Recorder's Office. The final plat is kept on file and becomes part of the permanent record for the subject site. (Am. Admin. Directive, 5/14/2013) 2-07.3.0 SUBMITTAL TIMING Review of final plats is normally initiated after the tentative plat has been approved, unless concurrent tentative and final plat submittal has been approved by the PDSD prior to submittal. Final plats may also be submitted for review prior to the approval of a tentative if a minimum of one review of the tentative plat have occurred. In any case, submittal of the final plat prior to approval of the tentative plat is done at the applicant's risk since changes could be required of the tentative that may affect the final plat. 2-07.4.0 FORMAT REQUIREMENTS 2-07.5.1.A.2 Label the section, township, and range; section corners; north arrow; and the scale; 1. COMMENT: 2-07.5.1.A.2 Label the scale of the location map to three inches equals one mile. 2-07.5.1.A.3 Subdivisions, arterial and collector streets, major watercourses, and railroads within the one-mile area; and, 2. COMMENT: 2-07.5.1.A.3 Label Old Spanish Trail on the location map. 2-07.5.1.H - The Subdivision Case number assigned to the final plat and the DP case number assigned to the approved tentative plat must be placed in the lower right corner of the plat next to the title block. If the property is subject to a rezoning case, the C9-__-__ rezoning case number is to be noted also. 3. COMMENT: 2-07.5.1.H List the subdivision case number S19-067 and the rezoning case number C9-85-95 in the lower right hand side of all plan sheets. 4. COMMENT: 2-075.3.E See engineering review comments for applicability of the assurances general note. 2-07.5.4 Proposed Subdivision Information Provide the following information on the plat: 2-07.5.4.A. Indicate the name and width of each street, alley, easement (type), and drainage way within the subdivision boundary being created by this plat. Label each as public or private, along with the appropriate dedication notation; 5. COMMENT: 2-07.5.4.A Provide documentation related to any cross access easements within the shopping center and the development towards the east. Draw, label, and dimension the cross access easements on two and three or as required. 2-07.5.4.H. Show no-vehicular access easements where applicable; 6. COMMENT: 2-07.5.4.H If applicable indicate the locations of any proposed no-vehicular access easements. If you have any questions about this transmittal, Contact Martin Escalante at (520) 837-4082 or by email Martin.Escalante@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat. |
| 09/19/2019 | MESCALA1 | ZONING HC | REVIEW | Passed | |
| 09/20/2019 | JIM EGAN | COT NON-DSD | FIRE | Completed | |
| 09/30/2019 | ALEXANDRA HINES | PIMA COUNTY | WASTEWATER | Reqs Change | Obtain approval and provide in resubmittal the following: 09/17/2019 P19WS00045 Sewer Layout Approval Site Uhaul at Broadway & Camino Seco, Lots 1-3 Final Block Plat Request for Corrections |
| 10/09/2019 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 10/14/2019 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Approved | |
| 10/15/2019 | SBEASLE1 | UTILITIES | TUCSON ELECTRIC POWER | Reqs Change | (The "three copies of the easements" mentioned below can be viewed on PRO in the "Documents" section) Tucson Electric Power Co., (TEP) has reviewed the final plat submitted on September 18, 2019, and is unable to approve at this time. Please revise the TEP easement recorded in Bk 4347 Pg 827 to depict the entire easement. Additionally, TEP easements recorded in Bk 4086 Pg 551 and Bk 11683 Pg 4665 need to be identified on the final plat. Copies of the easements are attached for your reference. If there are any questions, please contact me at 520-917-8744. Thank you, Mary Burke, Senior Right of Way Agent Tucson Electric Power Co. Land Resources – RC 131, 3950 E. Irvington Road Tucson, AZ 85714-2114 Office - 520-917-8744, Cell - 520-401-9895, mburke@tep.com |
| 10/15/2019 | KAY MARKS | PIMA COUNTY | ADDRESSING | Reqs Change | (The "attached PDF" mentioned below can be viewed on PRO in the "Documents" section) S19-067 / 1st submittal / U-Haul is being Returned For Corrections (one minor correction) by Pima County Addressing. The attached pdf contains Addressing’s comments. Please let me know if you have any questions. Thank you, Robin Freiman, Addressing Official Pima County Development Services Department 201 N Stone AV – 4th Floor Tucson, AZ 85701 (520) 724-7570 |
| 10/15/2019 | SBEASLE1 | COT NON-DSD | PARKS & RECREATION | Approved | No existing or proposed Tucson Parks and Recreation facilities are affected by this Block Plat. Howard B. Dutt, RLA Landscape Architect Tucson Parks & Recreation, (520) 837-8040 Howard.Dutt@tucsonaz.gov |
| 10/18/2019 | ROBERT SHERRY | PLUMBING-RESIDENTIAL | REVIEW | Completed | |
| 10/22/2019 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Reqs Change | S19-067 1) Add the required Assurances block found in the City of Tucson (COT) Administrative Manual (AM) section 2-07.5.3.E. Change "City of Tucson PDSD Engineering Administrator" to "City of Tucson Engineer" 2) There appears to be a fire hydrant in the middle of proposed lot 2. No easements for a service line are shown. Clarify if any easements exist to the fire hydrant John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov 520-837-5007 |
| 10/24/2019 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | PLAN RETURNED FOR CORRECTIONS NOTICE - A resubmittal is required Permit/Activity Number: S19-067 Project Description: FINAL BLOCK PLAT - U-Haul, Lots 1-3, subdivide into three parcels. The fee balance is $0 (zero). Thank you for the payment. To view the review comments: www.tucsonaz.gov/PRO, enter the Permit/Activity Number. (If information isn't shown yet, check back later as data uploads to PRO periodically.) Submit the following items to the PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd. In the Project Description field, please include the Activity Number. 1) Comment Response Letter (your response to the reviewer's “Requires changes” comments) 2) Plan Set (all pages, full set) 3) Any other documents requested by review staff 4) Name your 2nd submittal documents accordingly, for example: 2_Plan_Set Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services Attn: Permit Counter/Payments 201 N. Stone Avenue, First Floor Tucson, AZ 85701 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/24/2019 | SBEASLE1 | OUT TO CUSTOMER | Completed |