Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Plan Review Detail
Review Status: Completed
Review Details: FINAL PLAT - REVIEW
Plan Number - S19-058
Review Name: FINAL PLAT - REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/23/2021 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 03/24/2021 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Reqs Change | FROM: Suzanne Gilpin, GIS Cartographer, Pima County Assessor's Office, (520)724-4387 DATE: March 23, 2021 RE: Assessor's Review and Comments Regarding Final Plat- S19-058 PLACITA DEL RIO (NEW CHANGES) - 3RD SUBMITTAL __X___ Plat does not meet Assessor's Office requirements. COMMENTS: 1. The perimeter line must be solid and the heaviest lineweight on the plat. The lot lines and common area lines must be solid and the next heaviest. Lines for erosion setbacks, floodplain lines etc. should be the lightest lineweight and be dashed or dot-dashed. |
| 03/30/2021 | JVINCEN1 | COT NON-DSD | FIRE | Approved | |
| 04/07/2021 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 04/15/2021 | SBEASLE1 | COT NON-DSD | PARKS & RECREATION | Approved | From: Howard Dutt Thu 4/15/2021 9:57 AM (email) No Tucson Parks and Recreation facilities are affected by this Minor Subdivision. Howard B. Dutt, RLA, Landscape Architect Tucson Parks and Recreation (520) 837-8040 |
| 04/16/2021 | AWARNER1 | ZONING | REVIEW | Approved | |
| 04/20/2021 | SSHIELD1 | LANDSCAPE | REVIEW | Approved | |
| 04/20/2021 | SBLOOD1 | ENGINEERING | REVIEW | Approved | |
| 04/26/2021 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | Email from: TEPDEVREV@tep.com To: CDRC Mon 4/26/2021 9:59 AM Tucson Electric Power Co. (TEP) has reviewed and has no objection the PLACITA DEL RIO, S19-058, submitted on March 23rd, 2021. Please note the perimeter line should be a solid line to identify subject property. Please call the New Construction Department at 520-918-8300 to apply for service. Submit a final set of approved plans including electrical load and offsite improvement plans to determine how TEP will serve this development. If easements are required, they will be obtained by separate instrument. Removal or relocation of existing TEP facilities will be at the Developer’s expense. Thank you kindly, Diane Geerligs, Right of Way Agent Tucson Electric Power Company 3950 E. Irvington Rd. | Tucson, AZ 85714-2114 Mail Stop Land Resources RC131 (o) 520-396-2536| (m) 520-730-1974 | dgeerligs@tep.com |
| 04/26/2021 | CHRIS POIRIER | PIMA COUNTY | ADDRESSING | Approved | Email sent from: Nicholas Jordan <Addressing@pima.gov> To: CDRC Mon 4/26/2021 1:09 PM Pima County Addressing will maintain the initial approval of the project and request that the address annotations on the lots be removed before mylars are submitted. Thank you Nicholas Jordan, Addressing Specialist Pima County Development Services Department 201 N Stone AV – 1st Floor Tucson, AZ 85701 (520) 724-9623 |
| 04/28/2021 | SBEASLE1 | COT NON-DSD | TRAFFIC | Approved | Email from: David Stiffey To: CDRC Wed 4/28/2021 2:52 PM S19-058 -No Comments regarding traffic David Stiffey |
| 04/30/2021 | SAMUEL ROGERS | ZONING-DECISION LETTER | REVIEW | Reqs Change | April 30, 2021 Grenier Engineering Attn: Jason Morse 6300 East El Dorado Plaza Tucson, AZ 85715 Subject: Final Plat for (S19-058) Placita Del Rio Lots 1, 6, & 7 The above referenced project has been conditionally-approved by the City Development Review Committee (CDRC) to prepare for Mayor & Council approval. Please submit five (5) weeks in advance to the next available Mayor & Council meeting, June 22, 2021. Please take the following actions and upload PDF scans of items listed. Once Engineering approves folder in 'Final Plat Package' workflow (5-10 day review), then hand deliver items to 3rd floor lobby drop box for us to obtain City staff's signatures: 1. Address Pima County’s review comments along with comment response letter. 2. Original set of executed and notarized (permanent, black ink only) Final Plat on double matte océ or photo mylar. Fill in blank for 'filed at the request of ____'. Leave Date and Time blank. 3. Title report current within the last thirty (30) days or statement from Title Company certifying the title report previously submitted is still valid. 4. Check or money order made payable to “Pima County Recorder” in the amount of: $24.00 for the first plat sheet and $20.00 for each additional plat sheet (in other words: $20 per plat sheet plus a flat $4.00 handling fee), along with flat $30.00 fee per document for Consent to Dedicate and CC&R (if applicable). The City pays to record the Assurance Agreement. If you are unsure of the fees, please call the County Recorder’s Office at 520-740-4350. Check must be pre-printed with name and address and dated within 45 days of the scheduled Mayor & Council meeting. 5. Original set of executed and notarized CC&R (if applicable). 6. Original set of executed and notarized Assurance Agreement (if applicable). For Third Party Land Trust, provide original Agreement to Construct, original Amendment to Trust, and copy of Trust Agreement. 7. Property owner(s) and consultant mailing addresses to receive notification from the City Clerk’s Office one (1) week prior to and following Mayor & Council meeting. The Final Plat, CC&R, and Assurance Agreement must be approved at the same Mayor & Council meeting. The City Development Review Committee ensures the Assurance Agreement is reviewed by the City Attorney’s Office prior to the Mayor & Council meeting. The recorded CC&R will be mailed to the address on the cover sheet. The City Clerk’s Office keeps the recorded Final Plat and Assurance Agreement. A copy of the recorded Final Plat and Assurance Agreement will be available on www.tucsonaz.gov/pro. Should you have questions, contact Samuel Rogers at (520) 837-6932 or Samuel.Rogers@tucsonaz.gov. xc: Project Record by Activity Number |